Abstract

Introduction

Extracortical fixation techniques in anterior cruciate ligament reconstruction bear the risk of tunnel enlargement, while close-to-aperture fixations often show lower failure loads. The purpose for this study was to investigate the biomechanical benefits of a novel implant-free combination of an extra-cortical and close-to-aperture fixation.

Materials and methods

Quadrupled human cadaveric semitendinosus tendons were fixed to 30 porcine tibiae with either a cannulated interference screw (I), an implant-free post-fixation (S), or a novel pull-press fixation (P). Specimens were cyclically loaded 20 times between 20 and 60 N followed by 500 cycles with 60–200 N, followed by a load-to-failure test with 1 mm/s.

Results

The mean elongation of the tendons in the P-group during the 500 cycles between 60 and 200 N was significantly lower (5.69 ± 2.16 mm) compared to 9.20 ± 3.21 mm in S-group and 9.37 ± 3.1 mm in the I-group (p < 0.05). The mean maximum load-to-failure was significantly higher in the P-group (728.2 ± 76.4 N) compared to 476.4 ± 68.8 N in the S-group and 625.9 ± 82.5 N in the I-group (p < 0.05). Stiffness of the constructs in the P-group was significantly higher (121.7 ± 44.9 N/mm) compared to 46.2 ± 17.7 N/mm in the S- and 72.8 ± 29.8 N/mm in the I-group (p < 0.03).

Conclusions

This study indicates superior biomechanical properties of a novel implant-free tibial pull-press fixation to conventional implant-free and close-to-aperture interference screw fixations in terms of cyclic elongation and maximum load-to-failure.

Level of evidence

Not applicable, basic science study.
Literature
1.
go back to reference Clatworthy MG, Annear P, Bulow JU, Bartlett RJ (1999) Tunnel widening in anterior cruciate ligament reconstruction: a prospective evaluation of hamstring and patella tendon grafts. Knee Surg Sports Traumatol Arthrosc 7(3):138–145. doi:10.1007/s001670050138 CrossRefPubMed Clatworthy MG, Annear P, Bulow JU, Bartlett RJ (1999) Tunnel widening in anterior cruciate ligament reconstruction: a prospective evaluation of hamstring and patella tendon grafts. Knee Surg Sports Traumatol Arthrosc 7(3):138–145. doi:10.​1007/​s001670050138 CrossRefPubMed
2.
go back to reference Ettinger M, Liodakis E, Haasper C, Hurschler C, Breitmeier D, Krettek C, Jagodzinski M (2012) Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament. Unfallchirurg 115(9):811–815. doi:10.1007/s00113-010-1944-z CrossRefPubMed Ettinger M, Liodakis E, Haasper C, Hurschler C, Breitmeier D, Krettek C, Jagodzinski M (2012) Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament. Unfallchirurg 115(9):811–815. doi:10.​1007/​s00113-010-1944-z CrossRefPubMed
3.
4.
go back to reference Gartsman GM, Drake G, Edwards TB, Elkousy HA, Hammerman SM, O’Connor DP, Press CM (2013) Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study. J Shoulder Elbow Surg 22(11):1480–1487. doi:10.1016/j.jse.2013.06.020 CrossRefPubMed Gartsman GM, Drake G, Edwards TB, Elkousy HA, Hammerman SM, O’Connor DP, Press CM (2013) Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study. J Shoulder Elbow Surg 22(11):1480–1487. doi:10.​1016/​j.​jse.​2013.​06.​020 CrossRefPubMed
6.
go back to reference Hertel P, Behrend H, Cierpinski T, Musahl V, Widjaja G (2005) ACL reconstruction using bone-patellar tendon-bone press-fit fixation: 10-year clinical results. Knee Surg Sports Traumatol Arthrosc 13(4):248–255CrossRefPubMed Hertel P, Behrend H, Cierpinski T, Musahl V, Widjaja G (2005) ACL reconstruction using bone-patellar tendon-bone press-fit fixation: 10-year clinical results. Knee Surg Sports Traumatol Arthrosc 13(4):248–255CrossRefPubMed
7.
go back to reference Hoffmann RF, Peine R, Bail HJ, Sudkamp NP, Weiler A (1999) Initial fixation strength of modified patellar tendon grafts for anatomic fixation in anterior cruciate ligament reconstruction. Arthroscopy 15(4):392–399CrossRefPubMed Hoffmann RF, Peine R, Bail HJ, Sudkamp NP, Weiler A (1999) Initial fixation strength of modified patellar tendon grafts for anatomic fixation in anterior cruciate ligament reconstruction. Arthroscopy 15(4):392–399CrossRefPubMed
9.
go back to reference Jagodzinski M, Geiges B, von Falck C, Knobloch K, Haasper C, Brand J, Hankemeier S, Krettek C, Meller R (2010) Biodegradable screw versus a press-fit bone plug fixation for hamstring anterior cruciate ligament reconstruction: a prospective randomized study. Am J Sports Med 38(3):501–508. doi:10.1177/0363546509350325 CrossRefPubMed Jagodzinski M, Geiges B, von Falck C, Knobloch K, Haasper C, Brand J, Hankemeier S, Krettek C, Meller R (2010) Biodegradable screw versus a press-fit bone plug fixation for hamstring anterior cruciate ligament reconstruction: a prospective randomized study. Am J Sports Med 38(3):501–508. doi:10.​1177/​0363546509350325​ CrossRefPubMed
10.
go back to reference Jagodzinski M, Scheunemann K, Knobloch K, Albrecht K, Krettek C, Hurschler C, Zeichen J (2006) Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction. Knee Surg Sports Traumatol Arthrosc 14(12):1281–1287. doi:10.1007/s00167-006-0105-y CrossRefPubMed Jagodzinski M, Scheunemann K, Knobloch K, Albrecht K, Krettek C, Hurschler C, Zeichen J (2006) Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction. Knee Surg Sports Traumatol Arthrosc 14(12):1281–1287. doi:10.​1007/​s00167-006-0105-y CrossRefPubMed
11.
go back to reference Jansson KA, Harilainen A, Sandelin J, Karjalainen PT, Aronen HJ, Tallroth K (1999) Bone tunnel enlargement after anterior cruciate ligament reconstruction with the hamstring autograft and endobutton fixation technique. A clinical, radiographic and magnetic resonance imaging study with 2 years follow-up. Knee Surg Sports Traumatol Arthrosc 7(5):290–295CrossRefPubMed Jansson KA, Harilainen A, Sandelin J, Karjalainen PT, Aronen HJ, Tallroth K (1999) Bone tunnel enlargement after anterior cruciate ligament reconstruction with the hamstring autograft and endobutton fixation technique. A clinical, radiographic and magnetic resonance imaging study with 2 years follow-up. Knee Surg Sports Traumatol Arthrosc 7(5):290–295CrossRefPubMed
12.
go back to reference Kautzner J, Kos P, Hanus M, Trc T, Havlas V (2014) A comparison of ACL reconstruction using patellar tendon versus hamstring autograft in female patients: a prospective randomised study. Int Orthop. doi:10.1007/s00264-014-2495-7 Kautzner J, Kos P, Hanus M, Trc T, Havlas V (2014) A comparison of ACL reconstruction using patellar tendon versus hamstring autograft in female patients: a prospective randomised study. Int Orthop. doi:10.​1007/​s00264-014-2495-7
13.
go back to reference Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31(2):174–181PubMed Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31(2):174–181PubMed
14.
go back to reference Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site. Am J Sports Med 31(2):182–188PubMed Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site. Am J Sports Med 31(2):182–188PubMed
15.
16.
go back to reference L’Insalata JC, Klatt B, Fu FH, Harner CD (1997) Tunnel expansion following anterior cruciate ligament reconstruction: a comparison of hamstring and patellar tendon autografts. Knee Surg Sports Traumatol Arthrosc 5(4):234–238. doi:10.1007/s001670050056 CrossRefPubMed L’Insalata JC, Klatt B, Fu FH, Harner CD (1997) Tunnel expansion following anterior cruciate ligament reconstruction: a comparison of hamstring and patellar tendon autografts. Knee Surg Sports Traumatol Arthrosc 5(4):234–238. doi:10.​1007/​s001670050056 CrossRefPubMed
17.
go back to reference Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27(1):35–43PubMed Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27(1):35–43PubMed
18.
go back to reference Noyes FR, Barber-Westin SD (2001) Revision anterior cruciate ligament reconstruction: report of 11-year experience and results in 114 consecutive patients. Instr Course Lect 50:451–461PubMed Noyes FR, Barber-Westin SD (2001) Revision anterior cruciate ligament reconstruction: report of 11-year experience and results in 114 consecutive patients. Instr Course Lect 50:451–461PubMed
19.
go back to reference Nurmi JT, Sievanen H, Kannus P, Jarvinen M, Jarvinen TL (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32(3):765–771CrossRefPubMed Nurmi JT, Sievanen H, Kannus P, Jarvinen M, Jarvinen TL (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32(3):765–771CrossRefPubMed
20.
go back to reference Paessler HH, Mastrokalos DS (2003) Anterior cruciate ligament reconstruction using semitendinosus and gracilis tendons, bone patellar tendon, or quadriceps tendon-graft with press-fit fixation without hardware. A new and innovative procedure. Orthop Clin North Am 34(1):49–64CrossRefPubMed Paessler HH, Mastrokalos DS (2003) Anterior cruciate ligament reconstruction using semitendinosus and gracilis tendons, bone patellar tendon, or quadriceps tendon-graft with press-fit fixation without hardware. A new and innovative procedure. Orthop Clin North Am 34(1):49–64CrossRefPubMed
21.
go back to reference Seil R, Rupp S, Krauss PW, Benz A, Kohn DM (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26(6):815–819PubMed Seil R, Rupp S, Krauss PW, Benz A, Kohn DM (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26(6):815–819PubMed
22.
go back to reference Webster KE, Feller JA, Hameister KA (2001) Bone tunnel enlargement following anterior cruciate ligament reconstruction: a randomised comparison of hamstring and patellar tendon grafts with 2-year follow-up. Knee Surg Sports Traumatol Arthrosc 9(2):86–91CrossRefPubMed Webster KE, Feller JA, Hameister KA (2001) Bone tunnel enlargement following anterior cruciate ligament reconstruction: a randomised comparison of hamstring and patellar tendon grafts with 2-year follow-up. Knee Surg Sports Traumatol Arthrosc 9(2):86–91CrossRefPubMed
23.
go back to reference Weiler A, Hoffmann RF, Bail HJ, Rehm O, Sudkamp NP (2002) Tendon healing in a bone tunnel. Part II: histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy 18(2):124–135CrossRefPubMed Weiler A, Hoffmann RF, Bail HJ, Rehm O, Sudkamp NP (2002) Tendon healing in a bone tunnel. Part II: histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy 18(2):124–135CrossRefPubMed
25.
go back to reference Wipfler B, Donner S, Zechmann CM, Springer J, Siebold R, Paessler HH (2011) Anterior cruciate ligament reconstruction using patellar tendon versus hamstring tendon: a prospective comparative study with 9-year follow-up. Arthroscopy 27(5):653–665. doi:10.1016/j.arthro.2011.01.015 CrossRefPubMed Wipfler B, Donner S, Zechmann CM, Springer J, Siebold R, Paessler HH (2011) Anterior cruciate ligament reconstruction using patellar tendon versus hamstring tendon: a prospective comparative study with 9-year follow-up. Arthroscopy 27(5):653–665. doi:10.​1016/​j.​arthro.​2011.​01.​015 CrossRefPubMed
26.
go back to reference Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22(11):1204–1210. doi:10.1016/j.arthro.2006.06.015 CrossRefPubMed Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22(11):1204–1210. doi:10.​1016/​j.​arthro.​2006.​06.​015 CrossRefPubMed
Metadata
Title
A novel implant-free tibial pull-press-fixation for ACL reconstruction
Authors
Sebastian Kwisda
Antonios Dratzidis
Max Ettinger
Mohamed Omar
Christof Hurschler
Maximilian Petri
Christian Krettek
Michael Jagodzinski
Publication date
01-11-2015
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 11/2015
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-015-2293-8

Other articles of this Issue 11/2015

Archives of Orthopaedic and Trauma Surgery 11/2015 Go to the issue