Skip to main content
Top
Published in: Journal of Medical Systems 12/2016

01-12-2016 | Systems-Level Quality Improvement

A Novel Endoscope System for Position Detection and Depth Estimation of the Ureter

Authors: Enmin Song, Feng Yu, Hong Liu, Ning Cheng, Yunlong Li, Lianghai Jin, Chih-Cheng Hung

Published in: Journal of Medical Systems | Issue 12/2016

Login to get access

Abstract

Iatrogenic injury of ureter occurs occasionally in the clinical laparoscopic surgery. The ureter injury may cause the serious complications and kidney damage. To avoid such an injury, it is necessary to detect the ureter position in real-time. Currently, the endoscope cannot perform this type of function in detecting the ureter position in real-time. In order to have the real-time display of ureter position during the surgical operation, we propose a novel endoscope system which consists of a modified endoscope light and a new lumiontron tube with the LED light. The endoscope light is modified to detect the position of ureter by using our proposed dim target detection algorithm (DTDA). To make this new system functioning, two algorithmic approaches are proposed for the display of ureter position. The horizontal position of ureter is detected by the center line extraction method and the depth of ureter is estimated by the depth estimation method. Experimental results demonstrate that the proposed endoscope system can extract the position and depth information of ureter and exhibit superior performance in terms of accuracy and stabilization.
Literature
1.
go back to reference Ciaccio, E.J., Bhagat, G., Lewis, S.K., Green, P.H., Suggestions for automatic quantitation of endoscopic image analysis to improve detection of small intestinal pathology in celiac disease patients. Comput. Biol. Med. 65: 364–368, 2015.CrossRefPubMed Ciaccio, E.J., Bhagat, G., Lewis, S.K., Green, P.H., Suggestions for automatic quantitation of endoscopic image analysis to improve detection of small intestinal pathology in celiac disease patients. Comput. Biol. Med. 65: 364–368, 2015.CrossRefPubMed
2.
go back to reference Ṡevo, I., Avramović, A., Balasingham, I., Elle, O., Bergsland, J., Aabakken, L., Edge density based automatic detection of inflammation in colonoscopy videos. Comput. Biol. Med. 72:138–150, 2016.CrossRefPubMed Ṡevo, I., Avramović, A., Balasingham, I., Elle, O., Bergsland, J., Aabakken, L., Edge density based automatic detection of inflammation in colonoscopy videos. Comput. Biol. Med. 72:138–150, 2016.CrossRefPubMed
3.
go back to reference Reynisson, P.J., Leira, H.O., Hernes, T.N., Hofstad, E.F., Scali, M., Sorger, H., Amundsen, T., Lindseth, F., Langø, T., Navigated bronchoscopy: a technical review. J. Bronchol. Int. Pulmonol. 21(3):242–264, 2014.CrossRef Reynisson, P.J., Leira, H.O., Hernes, T.N., Hofstad, E.F., Scali, M., Sorger, H., Amundsen, T., Lindseth, F., Langø, T., Navigated bronchoscopy: a technical review. J. Bronchol. Int. Pulmonol. 21(3):242–264, 2014.CrossRef
5.
go back to reference Lopez, A., and Liao, J.C., Emerging endoscopic imaging technologies for bladder cancer detection. Curr. Urol. Rep. 15(5):1–8, 2014.CrossRef Lopez, A., and Liao, J.C., Emerging endoscopic imaging technologies for bladder cancer detection. Curr. Urol. Rep. 15(5):1–8, 2014.CrossRef
6.
go back to reference Parpala-Spårman, T., Paananen, I., Santala, M., Ohtonen, P., Hellström, P., Increasing numbers of ureteric injuries after the introduction of laparoscopic surgery. Scand. J. Urol. Nephrol. 42(5):422–427, 2008.CrossRefPubMed Parpala-Spårman, T., Paananen, I., Santala, M., Ohtonen, P., Hellström, P., Increasing numbers of ureteric injuries after the introduction of laparoscopic surgery. Scand. J. Urol. Nephrol. 42(5):422–427, 2008.CrossRefPubMed
7.
go back to reference Schimpf, M., Gottenger, E., Wagner, J., Universal ureteral stent placement at hysterectomy to identify ureteral injury: a decision analysis. BJOG 115(9):1151–1158, 2008.CrossRefPubMed Schimpf, M., Gottenger, E., Wagner, J., Universal ureteral stent placement at hysterectomy to identify ureteral injury: a decision analysis. BJOG 115(9):1151–1158, 2008.CrossRefPubMed
8.
go back to reference Aronson, M.P., and Bose, T.M., Urinary tract injury in pelvic surgery. Clin. Obstet. Gynecol. 45(2):428–438, 2002.CrossRefPubMed Aronson, M.P., and Bose, T.M., Urinary tract injury in pelvic surgery. Clin. Obstet. Gynecol. 45(2):428–438, 2002.CrossRefPubMed
9.
go back to reference Harkki-Siren, P., Sjoberg, J., Tiitinen, A., Urinary tract injuries after hysterectomy. Obstet. Gynecol. 92(1):113–118, 1998.CrossRefPubMed Harkki-Siren, P., Sjoberg, J., Tiitinen, A., Urinary tract injuries after hysterectomy. Obstet. Gynecol. 92(1):113–118, 1998.CrossRefPubMed
10.
go back to reference Carley, M., McIntire, D., Carley, J., Schaffer, J., Incidence, risk factors and morbidity of unintended bladder or ureter injury during hysterectomy. Int. Urogynecol. J. 13(1):18–21, 2002.CrossRef Carley, M., McIntire, D., Carley, J., Schaffer, J., Incidence, risk factors and morbidity of unintended bladder or ureter injury during hysterectomy. Int. Urogynecol. J. 13(1):18–21, 2002.CrossRef
11.
go back to reference Bİlge, Y., Diagnostic neglect regarding ureter ligation after hysterectomy. Turkish J. Med. Sci. 37(4):239–242, 2007. Bİlge, Y., Diagnostic neglect regarding ureter ligation after hysterectomy. Turkish J. Med. Sci. 37(4):239–242, 2007.
12.
go back to reference Tulikangas, P.K., Smith, T., Falcone, T., Boparai, N., Walters, M.D., Gross and histologic characteristics of laparoscopic injuries with four different energy sources. Fertil. Steril. 75(4):806–810, 2001.CrossRefPubMed Tulikangas, P.K., Smith, T., Falcone, T., Boparai, N., Walters, M.D., Gross and histologic characteristics of laparoscopic injuries with four different energy sources. Fertil. Steril. 75(4):806–810, 2001.CrossRefPubMed
13.
go back to reference Selzman, A.A., and Spirnak, J.P., Iatrogenic ureteral injuries: a 20-year experience in treating 165 injuries. J. Urol. 155(3):878–881, 1996.CrossRefPubMed Selzman, A.A., and Spirnak, J.P., Iatrogenic ureteral injuries: a 20-year experience in treating 165 injuries. J. Urol. 155(3):878–881, 1996.CrossRefPubMed
14.
go back to reference Ghali, A.M., El Malik, E.M., Ibrahim, A.I., Ismail, G., Rashid, M., Ureteric injuries: diagnosis, management, and outcome. J. Trauma Acute Care Surg. 46(1):150–158, 1999.CrossRef Ghali, A.M., El Malik, E.M., Ibrahim, A.I., Ismail, G., Rashid, M., Ureteric injuries: diagnosis, management, and outcome. J. Trauma Acute Care Surg. 46(1):150–158, 1999.CrossRef
15.
go back to reference Nam, Y.-S., and Wexner, S.D., Clinical value of prophylactic ureteral stent indwelling during laparoscopic colorectal surgery. J. Korean Med. Sci. 17(5):633, 2002.CrossRefPubMedPubMedCentral Nam, Y.-S., and Wexner, S.D., Clinical value of prophylactic ureteral stent indwelling during laparoscopic colorectal surgery. J. Korean Med. Sci. 17(5):633, 2002.CrossRefPubMedPubMedCentral
16.
go back to reference Fu, W.-J., Wang, Z.-X., Li, G., Cui, F.-Z., Zhang, Y., Zhang, X., Comparison of a biodegradable ureteral stent versus the traditional double-j stent for the treatment of ureteral injury: an experimental study. Biomed. Mater. 7(6):065002, 2012.CrossRefPubMed Fu, W.-J., Wang, Z.-X., Li, G., Cui, F.-Z., Zhang, Y., Zhang, X., Comparison of a biodegradable ureteral stent versus the traditional double-j stent for the treatment of ureteral injury: an experimental study. Biomed. Mater. 7(6):065002, 2012.CrossRefPubMed
17.
go back to reference Tanaka, Y., Asada, H., Kuji, N., Yoshimura, Y., Ureteral catheter placement for prevention of ureteral injury during laparoscopic hysterectomy. J. Obstet. Gynaecol. Res. 34 (1): 67–72 , 2008.PubMed Tanaka, Y., Asada, H., Kuji, N., Yoshimura, Y., Ureteral catheter placement for prevention of ureteral injury during laparoscopic hysterectomy. J. Obstet. Gynaecol. Res. 34 (1): 67–72 , 2008.PubMed
18.
go back to reference Tsui, C., Klein, R., Garabrant, M., Minimally invasive surgery: national trends in adoption and future directions for hospital strategy. Surg. Endosc. 27(7):2253–2257, 2013.CrossRefPubMed Tsui, C., Klein, R., Garabrant, M., Minimally invasive surgery: national trends in adoption and future directions for hospital strategy. Surg. Endosc. 27(7):2253–2257, 2013.CrossRefPubMed
19.
go back to reference Geng, J., and Xie, J., Review of 3-d endoscopic surface imaging techniques. IEEE Sensors J. 14(4):945–960, 2014.CrossRef Geng, J., and Xie, J., Review of 3-d endoscopic surface imaging techniques. IEEE Sensors J. 14(4):945–960, 2014.CrossRef
20.
go back to reference Yang, L., Wang, J., Ando, T., Kubota, A., Yamashita, H., Sakuma, I., Chiba, T., Kobayashi, E., Vision-based endoscope tracking for 3d ultrasound image-guided surgical navigation. Comput. Med. Imaging Graph. 40:205–216, 2015.CrossRefPubMed Yang, L., Wang, J., Ando, T., Kubota, A., Yamashita, H., Sakuma, I., Chiba, T., Kobayashi, E., Vision-based endoscope tracking for 3d ultrasound image-guided surgical navigation. Comput. Med. Imaging Graph. 40:205–216, 2015.CrossRefPubMed
21.
go back to reference Kagawa, K., tanaka, E., Yamada, K., Kawahito, S., Tanida, J.: Deep-focus compound-eye camera with polarization filters for 3d endoscopes. In: SPIE BiOS, pp. 822714–822714 International Society for Optics and Photonics (2012) Kagawa, K., tanaka, E., Yamada, K., Kawahito, S., Tanida, J.: Deep-focus compound-eye camera with polarization filters for 3d endoscopes. In: SPIE BiOS, pp. 822714–822714 International Society for Optics and Photonics (2012)
22.
go back to reference Wang, Y., Liu, M., Liu, X., Zhao, Y., Dong, L., Hui, M., Zhai, X., Li, Y., Zhou, P.: A light efficiency uniformity detection system for medical rigid endoscope based on image processing. In: International Conference on Optical Instruments and Technology 2015, pp. 962307–962307 International Society for Optics and Photonics (2015) Wang, Y., Liu, M., Liu, X., Zhao, Y., Dong, L., Hui, M., Zhai, X., Li, Y., Zhou, P.: A light efficiency uniformity detection system for medical rigid endoscope based on image processing. In: International Conference on Optical Instruments and Technology 2015, pp. 962307–962307 International Society for Optics and Photonics (2015)
23.
go back to reference Selka, F., Nicolau, S., Agnus, V., Bessaid, A., Marescaux, J., Soler, L., Context-specific selection of algorithms for recursive feature tracking in endoscopic image using a new methodology. Comput. Med. Imaging Graph. 40:49–61, 2015.CrossRefPubMed Selka, F., Nicolau, S., Agnus, V., Bessaid, A., Marescaux, J., Soler, L., Context-specific selection of algorithms for recursive feature tracking in endoscopic image using a new methodology. Comput. Med. Imaging Graph. 40:49–61, 2015.CrossRefPubMed
24.
go back to reference Gill, B.S., Georgeson, K.E., Hardin, W.D. Jr: Image acquisition in laparoscopic and endoscopic surgery. In: Medical Imaging 1995, pp. 617–622 International Society for Optics and Photonics (1995) Gill, B.S., Georgeson, K.E., Hardin, W.D. Jr: Image acquisition in laparoscopic and endoscopic surgery. In: Medical Imaging 1995, pp. 617–622 International Society for Optics and Photonics (1995)
25.
go back to reference Liedlgruber, M., and Uhl, A., Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review. IEEE Rev. Biomed. Eng. 4:73–88, 2011.CrossRefPubMed Liedlgruber, M., and Uhl, A., Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review. IEEE Rev. Biomed. Eng. 4:73–88, 2011.CrossRefPubMed
Metadata
Title
A Novel Endoscope System for Position Detection and Depth Estimation of the Ureter
Authors
Enmin Song
Feng Yu
Hong Liu
Ning Cheng
Yunlong Li
Lianghai Jin
Chih-Cheng Hung
Publication date
01-12-2016
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 12/2016
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-016-0607-1

Other articles of this Issue 12/2016

Journal of Medical Systems 12/2016 Go to the issue