Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 9/2015

01-09-2015 | Original Article

A multi-vertebrae CT to US registration of the lumbar spine in clinical data

Authors: Simrin Nagpal, Purang Abolmaesumi, Abtin Rasoulian, Ilker Hacihaliloglu, Tamas Ungi, Jill Osborn, Victoria A. Lessoway, John Rudan, Melanie Jaeger, Robert N. Rohling, Dan P. Borschneck, Parvin Mousavi

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 9/2015

Login to get access

Abstract

Purpose

Spinal needle injections are widely applied to alleviate back pain and for anesthesia. Current treatment is performed either blindly with palpation or using fluoroscopy or computed tomography (CT). Both fluoroscopy and CT guidance expose patients to ionizing radiation. Ultrasound (US) guidance for spinal needle procedures is becoming more prevalent as an alternative. It is challenging to use US as the sole imaging modality for intraoperative guidance of spine needle injections due to the acoustic shadows created by the bony structures of the vertebra that limit visibility of the target areas for injection. We propose registration of CT and the US images to augment anatomical visualization for the clinician during spinal interventions guided by US.

Methods

The proposed method involves automatic global and multi-vertebrae registration to find the closest alignment between CT and US data. This is performed by maximizing the similarity between the two modalities using voxel intensity information as well as features extracted from the input volumes. In our method, the lumbar spine is first globally aligned between the CT and US data using intensity-based registration followed by point-based registration. To account for possible curvature change of the spine between the CT and US volumes, a multi-vertebrae registration step is also performed. Springs are used to constrain the movement of the individually transformed vertebrae to ensure the optimal alignment is a pose of the lumbar spine that is physically possible.

Results

Evaluation of the algorithm is performed on 10 clinical patient datasets. The registration approach was able to align CT and US datasets from initial misalignments of up to 25 mm, with a mean TRE of 1.37 mm. These results suggest that the proposed approach has the potential to offer a sufficiently accurate registration between clinical CT and US data.
Literature
1.
go back to reference Balki M, Lee Y, Halpern S, Carvalho J (2009) Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg 108(6):1876–1881CrossRefPubMed Balki M, Lee Y, Halpern S, Carvalho J (2009) Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg 108(6):1876–1881CrossRefPubMed
2.
go back to reference Conroy P, Luyet C, McCartney C, McHardy P (2013) Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach. Anesthesiol Res Pract 2013:525 818–525 824 Conroy P, Luyet C, McCartney C, McHardy P (2013) Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach. Anesthesiol Res Pract 2013:525 818–525 824
3.
go back to reference Falco F, Manchikanti L, Datta S, Sehgal N, Geffert S, Onyewu O, Zhu J, Coubarous S, Hameed M, Ward S, Sharma M, Hameed H, Singh V, Boswell M (2012) An update of the effectiveness of therapeutic lumbar facet joint interventions. Pain Physician 15:E909–E953PubMed Falco F, Manchikanti L, Datta S, Sehgal N, Geffert S, Onyewu O, Zhu J, Coubarous S, Hameed M, Ward S, Sharma M, Hameed H, Singh V, Boswell M (2012) An update of the effectiveness of therapeutic lumbar facet joint interventions. Pain Physician 15:E909–E953PubMed
4.
go back to reference Fedorov A, Tuncali K, Fennessy FM, Tokuda J, Hata N, Wells WM, Kikinis R, Tempany CM, Tempany CM (2012) Image registration for targeted MRI-guided transperineal prostate biopsy. J Magn Reson Imaging 36(4):987–9926PubMedCentralCrossRefPubMed Fedorov A, Tuncali K, Fennessy FM, Tokuda J, Hata N, Wells WM, Kikinis R, Tempany CM, Tempany CM (2012) Image registration for targeted MRI-guided transperineal prostate biopsy. J Magn Reson Imaging 36(4):987–9926PubMedCentralCrossRefPubMed
5.
go back to reference Foroughi P, Boctor E, Swartz M, Taylor R, Fichtinger G (2007) P6d–2 ultrasound bone segmentation using dynamic programming. In: Ultrasonics symposium New York, NY, USA, pp 2523–2526 Foroughi P, Boctor E, Swartz M, Taylor R, Fichtinger G (2007) P6d–2 ultrasound bone segmentation using dynamic programming. In: Ultrasonics symposium New York, NY, USA, pp 2523–2526
6.
go back to reference Gill S, Abolmaesumi P, Fichtinger G, Boisvert J, Pichora D, Borshneck D, Mousavi P (2012) Biomechanically constrained groupwise ultrasound to CT registration of the lumbar spine. Med Image Anal 16(3):662–674CrossRefPubMed Gill S, Abolmaesumi P, Fichtinger G, Boisvert J, Pichora D, Borshneck D, Mousavi P (2012) Biomechanically constrained groupwise ultrasound to CT registration of the lumbar spine. Med Image Anal 16(3):662–674CrossRefPubMed
7.
go back to reference Hacihaliloglu I, Rasoulian A, Rohling R, Abolmaesumi P (2013) Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features. In: Medical image computing and computer-assisted intervention-MICCAI, pp 361–368 Hacihaliloglu I, Rasoulian A, Rohling R, Abolmaesumi P (2013) Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features. In: Medical image computing and computer-assisted intervention-MICCAI, pp 361–368
8.
go back to reference Herring J, Dawant B, Maurer C, Muratore D, Galloway R Jr, Fitzpatrick J (1998) Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study. IEEE Trans Med Imaging 17(5):743–752CrossRefPubMed Herring J, Dawant B, Maurer C, Muratore D, Galloway R Jr, Fitzpatrick J (1998) Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study. IEEE Trans Med Imaging 17(5):743–752CrossRefPubMed
9.
go back to reference Johnson H, Harris G, Williams K (2007) Brainsfit: mutual information registrations of whole-brain 3D images, using the insight toolkit. Insight J Johnson H, Harris G, Williams K (2007) Brainsfit: mutual information registrations of whole-brain 3D images, using the insight toolkit. Insight J
10.
go back to reference Lasso A, Heffter T, Pinter C, Ungi T, Fichtinger G (2012) Implementation of the plus open-source toolkit for translational research of ultrasound-guided intervention systems. In: MICCAI workshop on systems and architectures for computer assisted interventions, Nice, France, pp 1–12 Lasso A, Heffter T, Pinter C, Ungi T, Fichtinger G (2012) Implementation of the plus open-source toolkit for translational research of ultrasound-guided intervention systems. In: MICCAI workshop on systems and architectures for computer assisted interventions, Nice, France, pp 1–12
11.
go back to reference Moore J, Clarke C, Bainbridge D, Wedlake C, Wiles A, Pace D, Peters T (2009) Image guidance for spinal facet injections using tracked ultrasound. In: Yang GZ, Hawkes D, Rueckert D, Noble A, Taylor C (eds) MICCAI 2009. LNCS 5761, pp 516–523 Moore J, Clarke C, Bainbridge D, Wedlake C, Wiles A, Pace D, Peters T (2009) Image guidance for spinal facet injections using tracked ultrasound. In: Yang GZ, Hawkes D, Rueckert D, Noble A, Taylor C (eds) MICCAI 2009. LNCS 5761, pp 516–523
12.
go back to reference Muratore DM, Russ JH, Dawant BM, Galloway R Jr (2002) Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study. Comput Aided Surg 7(6):342–352CrossRefPubMed Muratore DM, Russ JH, Dawant BM, Galloway R Jr (2002) Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study. Comput Aided Surg 7(6):342–352CrossRefPubMed
13.
go back to reference Myronenko A, Song X (2010) Point set registration: coherent point drift. IEEE Trans Pattern Anal Mach Intell 32(12):2262–2275 Myronenko A, Song X (2010) Point set registration: coherent point drift. IEEE Trans Pattern Anal Mach Intell 32(12):2262–2275
14.
go back to reference Nagpal S, Abolmaesumi P, Rasoulian A, Ungi T, Hacihaliloglu I, Osborn J, Borschneck D, Lessoway V, Rohling RN, Mousavi P (2014) CT to US registration of the lumbar spine: a clinical feasibility study. In: Stoyanov D, Collins L, Sakuma I, Abolmaesumi P, Jannin P (eds) IPCAI 2014. LNCS 8498, pp 108–117 Nagpal S, Abolmaesumi P, Rasoulian A, Ungi T, Hacihaliloglu I, Osborn J, Borschneck D, Lessoway V, Rohling RN, Mousavi P (2014) CT to US registration of the lumbar spine: a clinical feasibility study. In: Stoyanov D, Collins L, Sakuma I, Abolmaesumi P, Jannin P (eds) IPCAI 2014. LNCS 8498, pp 108–117
15.
go back to reference Pieper S, Halle M, Kikinis R (2004) 3D Slicer. In: IEEE symposium on biomedical imaging: nano to macro 2004, pp 632–635 Pieper S, Halle M, Kikinis R (2004) 3D Slicer. In: IEEE symposium on biomedical imaging: nano to macro 2004, pp 632–635
16.
go back to reference Pieper S, Lorensen B, Schroeder W, Kikinis R (2006) The NA-MIC kit: Itk, vtk, pipelines, grids and 3D slicer as an open platform for the medical image computing community. In: IEEE symposium on biomedical imaging: nano to macro 2006, pp 698–701 Pieper S, Lorensen B, Schroeder W, Kikinis R (2006) The NA-MIC kit: Itk, vtk, pipelines, grids and 3D slicer as an open platform for the medical image computing community. In: IEEE symposium on biomedical imaging: nano to macro 2006, pp 698–701
17.
go back to reference Rajpoot K, Grau V, Noble JA (2009) Local-phase based 3D boundary detection using monogenic signal and its application to real-time 3D echocardiography images. In: IEEE symposium on biomedical imaging: from nano to macro 2009, pp 783–786 Rajpoot K, Grau V, Noble JA (2009) Local-phase based 3D boundary detection using monogenic signal and its application to real-time 3D echocardiography images. In: IEEE symposium on biomedical imaging: from nano to macro 2009, pp 783–786
18.
go back to reference Rasoulian A, Rohling R, Abolmaesumi P (2012) Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine. In: proceedings of SPIE medical imaging, Orlando, Florida, USA, pp 8316:83161P-1-83161P-6 Rasoulian A, Rohling R, Abolmaesumi P (2012) Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine. In: proceedings of SPIE medical imaging, Orlando, Florida, USA, pp 8316:83161P-1-83161P-6
19.
go back to reference Rasoulian A, Abolmaesumi P, Mousavi P (2012) Feature-based multibody rigid registration of CT and ultrasound images of lumbar spine. Med Phys 39(6):3154–3166CrossRefPubMed Rasoulian A, Abolmaesumi P, Mousavi P (2012) Feature-based multibody rigid registration of CT and ultrasound images of lumbar spine. Med Phys 39(6):3154–3166CrossRefPubMed
20.
go back to reference Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model. IEEE Trans Med Imaging 32(10):1890–1900CrossRefPubMed Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model. IEEE Trans Med Imaging 32(10):1890–1900CrossRefPubMed
21.
go back to reference Ungi T, Abolmaesumi P, Jalal R, Welch M, Ayukawa I, Nagpal S, Lasso A, Jaeger M, Borschneck DP, Fichtinger G, Mousavi P (2012) Spinal needle navigation by tracked ultrasound snapshots. IEEE Trans Biomed Eng 59(10):2766–2772CrossRefPubMed Ungi T, Abolmaesumi P, Jalal R, Welch M, Ayukawa I, Nagpal S, Lasso A, Jaeger M, Borschneck DP, Fichtinger G, Mousavi P (2012) Spinal needle navigation by tracked ultrasound snapshots. IEEE Trans Biomed Eng 59(10):2766–2772CrossRefPubMed
22.
go back to reference Winter S, Brendel B, Pechlivanis I, Schmieder K, Igel C (2008) Registration of CT and intraoperative 3D ultrasound images of the spine using evolutionary and gradient-based methods. IEEE Trans Evolut Comput 12(3):284–296CrossRef Winter S, Brendel B, Pechlivanis I, Schmieder K, Igel C (2008) Registration of CT and intraoperative 3D ultrasound images of the spine using evolutionary and gradient-based methods. IEEE Trans Evolut Comput 12(3):284–296CrossRef
23.
go back to reference Yan CXB, Goulet B, Pelletier J, Chen SJ-S, Tampieri D, Collins DL (2011) Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery. Int J Comput Assist Radiol Surg 6(4):523–537CrossRefPubMed Yan CXB, Goulet B, Pelletier J, Chen SJ-S, Tampieri D, Collins DL (2011) Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery. Int J Comput Assist Radiol Surg 6(4):523–537CrossRefPubMed
Metadata
Title
A multi-vertebrae CT to US registration of the lumbar spine in clinical data
Authors
Simrin Nagpal
Purang Abolmaesumi
Abtin Rasoulian
Ilker Hacihaliloglu
Tamas Ungi
Jill Osborn
Victoria A. Lessoway
John Rudan
Melanie Jaeger
Robert N. Rohling
Dan P. Borschneck
Parvin Mousavi
Publication date
01-09-2015
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 9/2015
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1247-5

Other articles of this Issue 9/2015

International Journal of Computer Assisted Radiology and Surgery 9/2015 Go to the issue