Skip to main content
Top
Published in: International Orthopaedics 12/2017

01-12-2017 | Original Paper

A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity

Authors: Arnaud Dubory, Houssam Bouloussa, Guillaume Riouallon, Stéphane Wolff

Published in: International Orthopaedics | Issue 12/2017

Login to get access

Abstract

Purpose

Widely used in traumatic pelvic ring fractures, the iliosacral (IS) screw technique for spino-pelvic fixation remains anecdotal in adult spinal deformity. The objective of this study was to assess anatomical variability of the adult upper sacrum and to provide a user guide of spino-pelvic fixation with IS screws in adult spinal deformity.

Methods

Anatomical variability of the upper sacrum according to age, gender, height and weight was sought on 30 consecutive pelvic CT-scans. Thus, a user guide of spino-pelvic fixation with IS screws was modeled and assessed on ten CT-scans as described below. Two invariable landmarks usable during the surgical procedure were defined: point A (corresponding to the connector binding the IS screw to the spinal rod), equidistant from the first posterior sacral hole and the base of the S1 articular facet and 10 mm-embedded into the sacrum; point B (corresponding to the tip of the IS screw) located at the junction of the anterior third and middle third of the sacral endplate in the sagittal plane and at the middle of the endplate in the coronal plane. Point C corresponded to the intersection between the A-B direction and the external facet of the iliac wing. Three-dimensional reconstructions modeling the IS screw optimal direction according to the A-B-C straight line were assessed.

Results

Age had no effect on the anatomy of the upper sacrum. The distance between the base of the S1 superior articular facet and the top of the first posterior sacral hole was correlated with weight (r = 0.6; 95% CI [0.6–0.9]); p < 0.001). Sacral end-plate thickness increased for male patients (p < 0.001) and was strongly correlated with height (r = 0.6; 95% CI [0.29–0.75]); p < 0.001) and weight (r = 0.8; 95% CI [0.6–0.9]); p < 0.001). The thickness of the inferior part of the S1 vertebral body increased in male patients (p < 0.001). Other measured parameters slightly varied according to gender, height and weight. Simulating the described technique of pelvic fixation, no misplaced IS screw was found whatever the age, gender and morphologic parameters.

Conclusion

This user guide of spinopelvic fixation with IS screws seems to be reliable and reproducible independently of age, gender and morphologic characteristics but needs clinical assessment.
Level of evidence: Level IV
Literature
1.
go back to reference Balderston RA, Winter RB, Moe JH, Bradford DS, Lonstein JE (1986) Fusion to the sacrum for nonparalytic scoliosis in the adult. Spine 11(8):824–829CrossRefPubMed Balderston RA, Winter RB, Moe JH, Bradford DS, Lonstein JE (1986) Fusion to the sacrum for nonparalytic scoliosis in the adult. Spine 11(8):824–829CrossRefPubMed
2.
go back to reference Shen FH, Mason JR, Shimer AL, Arlet VM (2013) Pelvic fixation for adult scoliosis. Eur Spine J 22(Suppl 2):S265–S275CrossRefPubMed Shen FH, Mason JR, Shimer AL, Arlet VM (2013) Pelvic fixation for adult scoliosis. Eur Spine J 22(Suppl 2):S265–S275CrossRefPubMed
3.
go back to reference Farcy JP, Rawlins BA, Glassman SD (1992) Technique and results of fixation to the sacrum with iliosacral screws. Spine 17(6 Suppl):S190–S195CrossRefPubMed Farcy JP, Rawlins BA, Glassman SD (1992) Technique and results of fixation to the sacrum with iliosacral screws. Spine 17(6 Suppl):S190–S195CrossRefPubMed
4.
go back to reference Tsuchiya K, Bridwell KH, Kuklo TR, Lenke LG, Baldus C (2006) Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity. Spine 31(3):303–308CrossRefPubMed Tsuchiya K, Bridwell KH, Kuklo TR, Lenke LG, Baldus C (2006) Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity. Spine 31(3):303–308CrossRefPubMed
5.
go back to reference Xu R, Ebraheim NA, Robke J, Yeasting RA (1996) Radiologic evaluation of iliosacral screw placement. Spine 21(5):582–588CrossRefPubMed Xu R, Ebraheim NA, Robke J, Yeasting RA (1996) Radiologic evaluation of iliosacral screw placement. Spine 21(5):582–588CrossRefPubMed
6.
go back to reference Mendel T, Radetzki F, Wohlrab D, Stock K, Hofmann GO, Noser H (2013) CT-based 3-D visualisation of secure bone corridors and optimal trajectories for sacroiliac screws. Injury 44(7):957–963CrossRefPubMed Mendel T, Radetzki F, Wohlrab D, Stock K, Hofmann GO, Noser H (2013) CT-based 3-D visualisation of secure bone corridors and optimal trajectories for sacroiliac screws. Injury 44(7):957–963CrossRefPubMed
7.
go back to reference Fischer S, Vogl TJ, Marzi I, Zangos S, Wichmann JL, Scholtz J-E et al (2015) Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: single center experience in treating posterior pelvic instability. Eur J Radiol 84(2):290–294CrossRefPubMed Fischer S, Vogl TJ, Marzi I, Zangos S, Wichmann JL, Scholtz J-E et al (2015) Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: single center experience in treating posterior pelvic instability. Eur J Radiol 84(2):290–294CrossRefPubMed
8.
go back to reference Wu T, Chen W, Li X, Zhang Q, Lv H-Z, Zhang Y-Z (2015) Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model. Int J Clin Exp Med 8(2):1853–1861PubMedPubMedCentral Wu T, Chen W, Li X, Zhang Q, Lv H-Z, Zhang Y-Z (2015) Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model. Int J Clin Exp Med 8(2):1853–1861PubMedPubMedCentral
9.
go back to reference Reuther G, Röhner U, Will T, Dehne I, Petereit U (2014) CT-guided screw fixation of vertical sacral fractures in local anaesthesia using a standard CT. RöFo Fortschritte Auf Dem Geb Röntgenstrahlen Nukl 186(12):1134–1139CrossRef Reuther G, Röhner U, Will T, Dehne I, Petereit U (2014) CT-guided screw fixation of vertical sacral fractures in local anaesthesia using a standard CT. RöFo Fortschritte Auf Dem Geb Röntgenstrahlen Nukl 186(12):1134–1139CrossRef
10.
go back to reference Routt ML, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214CrossRefPubMed Routt ML, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214CrossRefPubMed
11.
go back to reference Matta JM, Tornetta P (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop (329):129–40 Matta JM, Tornetta P (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop (329):129–40
12.
go back to reference Dubousset J (1973) Pelvic obliquity. A three dimensional deformity. Paris Groupe d’étude de la scoliose Dubousset J (1973) Pelvic obliquity. A three dimensional deformity. Paris Groupe d’étude de la scoliose
13.
go back to reference Camp JF, Caudle R, Ashmun RD, Roach J (1990) Immediate complications of Cotrel-Dubousset instrumentation to the sacro-pelvis. A clinical and biomechanical study. Spine 15(9):932–941CrossRefPubMed Camp JF, Caudle R, Ashmun RD, Roach J (1990) Immediate complications of Cotrel-Dubousset instrumentation to the sacro-pelvis. A clinical and biomechanical study. Spine 15(9):932–941CrossRefPubMed
14.
go back to reference Ould-Slimane M, Miladi L, Rousseau M-A, Bonaccorsi R, Catonne Y, Lazennec J-Y et al (2013) Sacropelvic fixation with iliosacral screws: applications and results in adult spinal deformities. J Spinal Disord Tech 26(4):212–217CrossRefPubMed Ould-Slimane M, Miladi L, Rousseau M-A, Bonaccorsi R, Catonne Y, Lazennec J-Y et al (2013) Sacropelvic fixation with iliosacral screws: applications and results in adult spinal deformities. J Spinal Disord Tech 26(4):212–217CrossRefPubMed
15.
go back to reference Miladi L, Journe A, Mousny M (2013) H3S2 (3 hooks, 2 screws) construct: a simple growing rod technique for early onset scoliosis. Eur Spine J 22(Suppl 2):S96–105CrossRefPubMed Miladi L, Journe A, Mousny M (2013) H3S2 (3 hooks, 2 screws) construct: a simple growing rod technique for early onset scoliosis. Eur Spine J 22(Suppl 2):S96–105CrossRefPubMed
16.
go back to reference Zahi R, Vialle R, Abelin K, Mary P, Khouri N, Damsin J-P (2010) Spinopelvic fixation with iliosacral screws in neuromuscular spinal deformities: results in a prospective cohort of 62 patients. Childs Nerv Syst 26(1):81–86CrossRefPubMed Zahi R, Vialle R, Abelin K, Mary P, Khouri N, Damsin J-P (2010) Spinopelvic fixation with iliosacral screws in neuromuscular spinal deformities: results in a prospective cohort of 62 patients. Childs Nerv Syst 26(1):81–86CrossRefPubMed
17.
go back to reference Miladi LT, Ghanem IB, Draoui MM, Zeller RD, Dubousset JF (1997) Iliosacral screw fixation for pelvic obliquity in neuromuscular scoliosis. A long-term follow-up study. Spine 22(15):1722–1729CrossRefPubMed Miladi LT, Ghanem IB, Draoui MM, Zeller RD, Dubousset JF (1997) Iliosacral screw fixation for pelvic obliquity in neuromuscular scoliosis. A long-term follow-up study. Spine 22(15):1722–1729CrossRefPubMed
18.
go back to reference Ziran BH, Wasan AD, Marks DM, Olson SA, Chapman MW (2007) Fluoroscopic imaging guides of the posterior pelvis pertaining to iliosacral screw placement. J Trauma 62(2):347–356 discussion 356 CrossRefPubMed Ziran BH, Wasan AD, Marks DM, Olson SA, Chapman MW (2007) Fluoroscopic imaging guides of the posterior pelvis pertaining to iliosacral screw placement. J Trauma 62(2):347–356 discussion 356 CrossRefPubMed
19.
go back to reference Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop 329:194–198CrossRef Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop 329:194–198CrossRef
20.
go back to reference Peretz AM, Hipp JA, Heggeness MH (1998) The internal bony architecture of the sacrum. Spine 23(9):971–974CrossRefPubMed Peretz AM, Hipp JA, Heggeness MH (1998) The internal bony architecture of the sacrum. Spine 23(9):971–974CrossRefPubMed
21.
go back to reference Ebraheim N, Sabry FF, Nadim Y, Xu R, Yeasting RA (2000) Internal architecture of the sacrum in the elderly. An anatomic and radiographic study. Spine 25(3):292–297CrossRefPubMed Ebraheim N, Sabry FF, Nadim Y, Xu R, Yeasting RA (2000) Internal architecture of the sacrum in the elderly. An anatomic and radiographic study. Spine 25(3):292–297CrossRefPubMed
22.
go back to reference Esenkaya I, Aluçlu MA, Kavakli A, Bulut HT (2003) Radiologic and morphologic evaluation of the lateral sacral mass. Acta Orthop Traumatol Turc 37(4):330–339PubMed Esenkaya I, Aluçlu MA, Kavakli A, Bulut HT (2003) Radiologic and morphologic evaluation of the lateral sacral mass. Acta Orthop Traumatol Turc 37(4):330–339PubMed
23.
go back to reference Esenkaya I (2002) A morphologic evaluation of the sacroiliac joint and plate fixation on a pelvic model using a S1 pedicular screw, transiliosacral screws, and a compression rod for sacroiliac joint injuries. Acta Orthop Traumatol Turc 36(5):432–441PubMed Esenkaya I (2002) A morphologic evaluation of the sacroiliac joint and plate fixation on a pelvic model using a S1 pedicular screw, transiliosacral screws, and a compression rod for sacroiliac joint injuries. Acta Orthop Traumatol Turc 36(5):432–441PubMed
24.
go back to reference Miller AN, Routt MLC (2012) Variations in sacral morphology and implications for iliosacral screw fixation. J Am Acad Orthop Surg 20(1):8–16PubMed Miller AN, Routt MLC (2012) Variations in sacral morphology and implications for iliosacral screw fixation. J Am Acad Orthop Surg 20(1):8–16PubMed
25.
go back to reference Ebraheim NA, Xu R, Challgren E, Heck B (1998) Location of the sacral pedicle, foramina, and ala on the lateral aspect of the sacrum: a radiographic study. Orthopedics 21(6):703–706PubMed Ebraheim NA, Xu R, Challgren E, Heck B (1998) Location of the sacral pedicle, foramina, and ala on the lateral aspect of the sacrum: a radiographic study. Orthopedics 21(6):703–706PubMed
26.
go back to reference Ebraheim NA, Lu J, Biyani A, Galluch D, Yang H, Yeasting RA (2000) Location of the first and second sacral nerve roots in relation to pedicle screw placement. Am J Orthop Belle Mead NJ 29(11):873–877PubMed Ebraheim NA, Lu J, Biyani A, Galluch D, Yang H, Yeasting RA (2000) Location of the first and second sacral nerve roots in relation to pedicle screw placement. Am J Orthop Belle Mead NJ 29(11):873–877PubMed
28.
go back to reference Jackson H, Burke JT (1984) The sacral foramina. Skelet Radiol 11(4):282–288CrossRef Jackson H, Burke JT (1984) The sacral foramina. Skelet Radiol 11(4):282–288CrossRef
29.
go back to reference Ebraheim NA, Lin D, Xu R, Yeasting RA (1999) Evaluation of the upper sacrum by three-dimensional computed tomography. Am J Orthop 28(10):578–582PubMed Ebraheim NA, Lin D, Xu R, Yeasting RA (1999) Evaluation of the upper sacrum by three-dimensional computed tomography. Am J Orthop 28(10):578–582PubMed
30.
go back to reference Gras F, Gottschling H, Schröder M, Marintschev I, Hofmann GO, Burgkart R (2016) Transsacral osseous corridor anatomy is more amenable to screw insertion in males: a biomorphometric analysis of 280 Pelves. Clin Orthop 474(10):2304–2311CrossRefPubMedPubMedCentral Gras F, Gottschling H, Schröder M, Marintschev I, Hofmann GO, Burgkart R (2016) Transsacral osseous corridor anatomy is more amenable to screw insertion in males: a biomorphometric analysis of 280 Pelves. Clin Orthop 474(10):2304–2311CrossRefPubMedPubMedCentral
31.
32.
go back to reference Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop 242:83–97 Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop 242:83–97
33.
go back to reference Uribe JS, Deukmedjian AR (2015) Visceral, vascular, and wound complications following over 13,000 lateral interbody fusions: a survey study and literature review. Eur Spine J 24(Suppl 3):386–396CrossRefPubMed Uribe JS, Deukmedjian AR (2015) Visceral, vascular, and wound complications following over 13,000 lateral interbody fusions: a survey study and literature review. Eur Spine J 24(Suppl 3):386–396CrossRefPubMed
34.
go back to reference Giráldez-Sánchez MA, Lázaro-Gonzálvez Á, Martínez-Reina J, Serrano-Toledano D, Navarro-Robles A, Cano-Luis P et al (2015) Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis. Injury 46(2):327–332CrossRefPubMed Giráldez-Sánchez MA, Lázaro-Gonzálvez Á, Martínez-Reina J, Serrano-Toledano D, Navarro-Robles A, Cano-Luis P et al (2015) Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis. Injury 46(2):327–332CrossRefPubMed
35.
go back to reference Li C-L (2014) Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. Eur Rev Med Pharmacol Sci 18(18):2704–2708PubMed Li C-L (2014) Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. Eur Rev Med Pharmacol Sci 18(18):2704–2708PubMed
36.
go back to reference Egund N, Olsson TH, Schmid H, Selvik G (1978) Movements in the sacroiliac joints demonstrated with roentgen stereophotogrammetry. Acta Radiol Diagn (Stockh) 19(5):833–846CrossRef Egund N, Olsson TH, Schmid H, Selvik G (1978) Movements in the sacroiliac joints demonstrated with roentgen stereophotogrammetry. Acta Radiol Diagn (Stockh) 19(5):833–846CrossRef
Metadata
Title
A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity
Authors
Arnaud Dubory
Houssam Bouloussa
Guillaume Riouallon
Stéphane Wolff
Publication date
01-12-2017
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 12/2017
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3580-5

Other articles of this Issue 12/2017

International Orthopaedics 12/2017 Go to the issue