Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 3/2021

Open Access 01-05-2021 | Original Research

A comparison of the quality of image acquisition between two different sidestream dark field video-microscopes

Authors: Jonny Coppel, Vassiliki Bountziouka, Daniel Martin, Edward Gilbert-Kawai

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2021

Login to get access

Abstract

Sidestream dark field (SDF) imaging enables direct visualisation of the microvasculature from which quantification of key variables is possible. The new MicroScan USB3 (MS-U) video-microscope is a hand-held SDF device that has undergone significant technical upgrades from its predecessor, the MicroScan Analogue (MS-A). The MS-U claims superior quality of sublingual microcirculatory image acquisition over the MS-A, however, this has yet to be robustly confirmed. In this manuscript, we therefore compare the quality of image acquisition between these two devices. The microcirculation of healthy volunteers was visualised to generate thirty video images for each device. Two independent raters, blinded to the device type, graded the quality of the images according to the six different traits in the Microcirculation Image Quality Score (MIQS) system. Chi-squared tests and Kappa statistics were used to compare not only the distribution of scores between the devices, but also agreement between raters. MS-U showed superior image quality over MS-A in three of out six MIQS traits; MS-U had significantly more optimal images by illumination (MS-U 95% optimal images, MS-A 70% optimal images (p-value 0.003)), by focus (MS-U 70% optimal images, MS-A 35% optimal images (p-value 0.002)) and by pressure (MS-U 72.5% optimal images, MS-A 47.5% optimal images (p-value 0.02)). For each trait, there was at least 85% agreement between the raters, and all the scores for each trait were independent of the rater (all p-values > 0.05). These results show that the new MS-U provides a superior quality of sublingual microcirculatory image acquisition when compared to old MS-A
Literature
1.
go back to reference Scorcella C, Damiani E, Domizi R, Pierantozzi S, Tondi S, Casetti A, et al. MicroDAIMON study: microcirculatory DAIly MONitoring in critically ill patients: a prospective observational study. Annals of Intensive Care. 2018;8:64.CrossRef Scorcella C, Damiani E, Domizi R, Pierantozzi S, Tondi S, Casetti A, et al. MicroDAIMON study: microcirculatory DAIly MONitoring in critically ill patients: a prospective observational study. Annals of Intensive Care. 2018;8:64.CrossRef
2.
go back to reference Ince C. The microcirculation is the motor of sepsis. Crit Care. 2005;9(Suppl 4):13–9.CrossRef Ince C. The microcirculation is the motor of sepsis. Crit Care. 2005;9(Suppl 4):13–9.CrossRef
3.
go back to reference Bauer A, Kofler S, Thiel M, Eifert S, Christ F. Monitoring of the sublingual microcirculation in cardiac surgery using orthogonal polarization spectral imaging: preliminary results. Anesthesiology. 2007;107(6):939–45.CrossRef Bauer A, Kofler S, Thiel M, Eifert S, Christ F. Monitoring of the sublingual microcirculation in cardiac surgery using orthogonal polarization spectral imaging: preliminary results. Anesthesiology. 2007;107(6):939–45.CrossRef
4.
go back to reference Meinders A, Elbers P. Leukocytosis and sublingual microvascular blood flow. N Engl J Med. 2009;360:e9.CrossRef Meinders A, Elbers P. Leukocytosis and sublingual microvascular blood flow. N Engl J Med. 2009;360:e9.CrossRef
5.
go back to reference Uz z, van Gulik T, Aydemirli M, Guerci P, Ince Y, Cuppen D, et al. Identification and quantification of human microcirculatory leukocytes using handheld video microscopes at the bedside. J Appl Physiol (1985). 2018;124(6):1550–7.CrossRef Uz z, van Gulik T, Aydemirli M, Guerci P, Ince Y, Cuppen D, et al. Identification and quantification of human microcirculatory leukocytes using handheld video microscopes at the bedside. J Appl Physiol (1985). 2018;124(6):1550–7.CrossRef
6.
go back to reference Uz Z, Ince C, Goerci P, Ince Y, Araujo RP, Ergin B, et al. Recruitment of sublingual microcirculation using handheld incident dark field imaging as a routine measurement tool during postoperative de-escalation phase- a pilot study in post ICU cardiac surgery patients. Perioperative Medicine. 2018;7:18.CrossRef Uz Z, Ince C, Goerci P, Ince Y, Araujo RP, Ergin B, et al. Recruitment of sublingual microcirculation using handheld incident dark field imaging as a routine measurement tool during postoperative de-escalation phase- a pilot study in post ICU cardiac surgery patients. Perioperative Medicine. 2018;7:18.CrossRef
7.
go back to reference Sherman H, Klausner S, Cook WA. Incident dark-field illumination: a new method for microcirculatory study. Angiology. 1971;22:295–303.CrossRef Sherman H, Klausner S, Cook WA. Incident dark-field illumination: a new method for microcirculatory study. Angiology. 1971;22:295–303.CrossRef
8.
go back to reference Aykut GIY, Ince C. A new generation computer controlled imaging sensor based hand held microscope for quantifying bedside microcirculatory alterations. In Annual update in Intensive Care and Emergency Medicine 2014 Edited by Vincent JL. Springer; 2014:pp. 367-pp. 385. Aykut GIY, Ince C. A new generation computer controlled imaging sensor based hand held microscope for quantifying bedside microcirculatory alterations. In Annual update in Intensive Care and Emergency Medicine 2014 Edited by Vincent JL. Springer; 2014:pp. 367-pp. 385.
9.
go back to reference Goedhart PT, Khalilzada M, Bezemer R, Merza J, Ince C. Sidestream Dark Field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation. Opt Express. Goedhart PT, Khalilzada M, Bezemer R, Merza J, Ince C. Sidestream Dark Field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation. Opt Express.
10.
go back to reference Cerny V. Sublingual microcirculation. Appl Cardiopulm Pathophysiol. 2012;16:229–48. Cerny V. Sublingual microcirculation. Appl Cardiopulm Pathophysiol. 2012;16:229–48.
11.
go back to reference Gilbert-kawai E, Coppel J, Bountzianka V, Ince C, Martin D. A comparison of the quality of image acquisition between the incident dark filed and sidestream dark filed videomicroscopes. BMC Med Imaging. 2016;16:10.CrossRef Gilbert-kawai E, Coppel J, Bountzianka V, Ince C, Martin D. A comparison of the quality of image acquisition between the incident dark filed and sidestream dark filed videomicroscopes. BMC Med Imaging. 2016;16:10.CrossRef
12.
go back to reference Ince C, Boerma EC, Cecconi M, De Backer D, Shapiro N, Duranteau J, et al. Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2018;44:281–99.CrossRef Ince C, Boerma EC, Cecconi M, De Backer D, Shapiro N, Duranteau J, et al. Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2018;44:281–99.CrossRef
13.
go back to reference Massey MJ, Larochelle E, Najarro G, Karmacharla A, Arnold R, Trzeciak S, et al. The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy. J Crit Care. 2013;28:913–7.CrossRef Massey MJ, Larochelle E, Najarro G, Karmacharla A, Arnold R, Trzeciak S, et al. The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy. J Crit Care. 2013;28:913–7.CrossRef
14.
go back to reference Hilty M, Gueric P, Ince Y, Toraman F, Ince C. MicroTools enables automated quantification of capillary density and red blood cell velocity in handhel vital microscopy. Commun Biol. 2019;2:217.CrossRef Hilty M, Gueric P, Ince Y, Toraman F, Ince C. MicroTools enables automated quantification of capillary density and red blood cell velocity in handhel vital microscopy. Commun Biol. 2019;2:217.CrossRef
Metadata
Title
A comparison of the quality of image acquisition between two different sidestream dark field video-microscopes
Authors
Jonny Coppel
Vassiliki Bountziouka
Daniel Martin
Edward Gilbert-Kawai
Publication date
01-05-2021
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2021
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00514-x

Other articles of this Issue 3/2021

Journal of Clinical Monitoring and Computing 3/2021 Go to the issue