Skip to main content
Top
Published in: European Journal of Applied Physiology 1-2/2005

01-05-2005 | Original Article

A comparison of muscular activity during single and double mouse clicks

Authors: Stefan Thorn, Mikael Forsman, Susan Hallbeck

Published in: European Journal of Applied Physiology | Issue 1-2/2005

Login to get access

Abstract

Work-related musculoskeletal disorders (WMSDs) in the neck/shoulder region and the upper extremities are a common problem among computer workers. Occurrences of motor unit (MU) double discharges with very short inter-firing intervals (doublets) have been hypothesised as a potential additional risk for overuse of already exhausted fibres during long-term stereotyped activity. Doublets are reported to be present during double-click mouse work tasks. A few comparative studies have been carried out on overall muscle activities for short-term tasks with single types of actions, but none on occurrences of doublets during double versus single clicks. The main purpose of this study was to compare muscle activity levels of single and double mouse clicks during a long-term combined mouse/keyboard work task. Four muscles were studied: left and right upper trapezius, right extensor digitorum communis (EDC) and right flexor carpi ulnaris. Additionally, MU activity was analysed through intramuscular electromyography in the EDC muscle for a selection of subjects. The results indicate that double clicking produces neither higher median or 90th percentile levels in the trapezius and EDC muscles, nor a higher disposition for MU doublets, than does single clicking. Especially for the 90th percentile levels, the indications are rather the opposite (in the EDC significantly higher during single clicks in 8 of 11 subjects, P<0.05). Although it cannot be concluded from the present study that double clicks are harmless, there were no signs that double clicks during computer work generally constitute a larger risk factor for WMSDs than do single clicks.
Literature
go back to reference Aarås A, Ro O (1997) Workload when using a mouse as an input device. Int J Hum Comp Interact 9(2):105–118 Aarås A, Ro O (1997) Workload when using a mouse as an input device. Int J Hum Comp Interact 9(2):105–118
go back to reference Abbate F, Bruton JD, De Haan A, Westerblad H (2002) Prolonged force increase following a high-frequency burst is not due to a sustained elevation of [Ca2+]i. Am J Physiol Cell Physiol 283:C42–C47 Abbate F, Bruton JD, De Haan A, Westerblad H (2002) Prolonged force increase following a high-frequency burst is not due to a sustained elevation of [Ca2+]i. Am J Physiol Cell Physiol 283:C42–C47
go back to reference Bawa P, Calancie B (1983) Repetitive doublets in human flexor carpi radialis muscle. J Phys [E] 339:123–132 Bawa P, Calancie B (1983) Repetitive doublets in human flexor carpi radialis muscle. J Phys [E] 339:123–132
go back to reference Bernard BP, Putz-Anderson V, Burt SE, Cole LL, Fairfield-Estill C, Fine LJ, Grant KA, Gjessing C, Jenkins L, Hurrell JJ, Nelson N, Pfirman D, Roberts R, Stetson D, Haring-Sweeney M, Tanaka S (1997) In: Bernard BP (ed) Musculoskeletal disorders and workplace factors. A critical review of epidemiologic evidence for work-related musculoskeletal disorders of the neck, upper extremity, and low back. Available at: http://www.cdc.gov/niosh/pdfs/97–141.pdf. DHHS (NIOSH) Publ No 97–141, chap 2 Bernard BP, Putz-Anderson V, Burt SE, Cole LL, Fairfield-Estill C, Fine LJ, Grant KA, Gjessing C, Jenkins L, Hurrell JJ, Nelson N, Pfirman D, Roberts R, Stetson D, Haring-Sweeney M, Tanaka S (1997) In: Bernard BP (ed) Musculoskeletal disorders and workplace factors. A critical review of epidemiologic evidence for work-related musculoskeletal disorders of the neck, upper extremity, and low back. Available at: http://​www.​cdc.​gov/​niosh/​pdfs/​97–141.pdf. DHHS (NIOSH) Publ No 97–141, chap 2
go back to reference Birch L, Juul-Kristensen B, Jensen C, Finsen L, Christensen H (2000) Acute response to precision, time pressure and mental demand during simulated computer work. Scand J Work Environ Health 26(4):299–305 Birch L, Juul-Kristensen B, Jensen C, Finsen L, Christensen H (2000) Acute response to precision, time pressure and mental demand during simulated computer work. Scand J Work Environ Health 26(4):299–305
go back to reference Blangsted AK, Olsen HB, Søgaard K (2001) Motor unit firing behaviour in human trapezius muscle during double clicking of computer mouse. In: Movement and sensation, International Symposium, Cairns, 3–6 September 2001 Blangsted AK, Olsen HB, Søgaard K (2001) Motor unit firing behaviour in human trapezius muscle during double clicking of computer mouse. In: Movement and sensation, International Symposium, Cairns, 3–6 September 2001
go back to reference Blatter BM, Bongers PM (2002) Duration of computer use and mouse use in relation to musculoskeletal disorders of neck or upper limb. Int J Ind Ergonom 30(4):295–306CrossRef Blatter BM, Bongers PM (2002) Duration of computer use and mouse use in relation to musculoskeletal disorders of neck or upper limb. Int J Ind Ergonom 30(4):295–306CrossRef
go back to reference Cutsem M van , Duchateau J, Hainaut K (1998) Changes in single motor unit behaviour contribute to the increase in contraction speed after dynamic training in humans. J Phys [E] 513(1):295–305CrossRef Cutsem M van , Duchateau J, Hainaut K (1998) Changes in single motor unit behaviour contribute to the increase in contraction speed after dynamic training in humans. J Phys [E] 513(1):295–305CrossRef
go back to reference Denslow JS (1948) Double discharges in human motor units. J Neurophysiol 11:209–215 Denslow JS (1948) Double discharges in human motor units. J Neurophysiol 11:209–215
go back to reference Desmedt JE, Godaux E (1977) Ballistic contractions in man: characteristic recruitment pattern of single motor units of the tibialis anterior muscle. J Phys [E] 264:673–693 Desmedt JE, Godaux E (1977) Ballistic contractions in man: characteristic recruitment pattern of single motor units of the tibialis anterior muscle. J Phys [E] 264:673–693
go back to reference Fogleman M, Lewis RJ (2002) Factors associated with self-reported musculoskeletal discomfort in video display terminal (VDT) users. Int J Ind Ergonom 29:311–318CrossRef Fogleman M, Lewis RJ (2002) Factors associated with self-reported musculoskeletal discomfort in video display terminal (VDT) users. Int J Ind Ergonom 29:311–318CrossRef
go back to reference Forsman M, Kadefors R, Zhang Q, Birch L, Palmerud G (1999) Motor-unit recruitment in the trapezius muscle during arm movements and in VDU precision work. Int J Ind Ergonom 24:619–630CrossRef Forsman M, Kadefors R, Zhang Q, Birch L, Palmerud G (1999) Motor-unit recruitment in the trapezius muscle during arm movements and in VDU precision work. Int J Ind Ergonom 24:619–630CrossRef
go back to reference Forsman M, Birch L, Zhang Q, Kadefors R (2001) Motor-unit recruitment in the trapezius muscle with special reference to coarse arm movements. J Electromyogr Kinesiol 11:207–216CrossRef Forsman M, Birch L, Zhang Q, Kadefors R (2001) Motor-unit recruitment in the trapezius muscle with special reference to coarse arm movements. J Electromyogr Kinesiol 11:207–216CrossRef
go back to reference Forsman M, Taoda K, Thorn S, Zhang Q (2002) Motor-unit recruitment during long-term isometric and wrist motion contractions: a study concerning muscular pain development in computer operators. Int J Ind Ergonom 30(4–5):237–250CrossRef Forsman M, Taoda K, Thorn S, Zhang Q (2002) Motor-unit recruitment during long-term isometric and wrist motion contractions: a study concerning muscular pain development in computer operators. Int J Ind Ergonom 30(4–5):237–250CrossRef
go back to reference Freriks B, Hermens H, Disselhorst-Klug C, Rau G (1999) The recommendations for sensors and sensor placement procedures for surface electromyography. In: Hermens H, Freriks B, Merletti R, Stegeman D, Blok J, Rau G, Disselhorst-Klug C and Hägg G (eds) SENIAM—deliverable 8—European recommendations for surface electromyography. Roessingh Research and Development, Enschede, pp 15–54 Freriks B, Hermens H, Disselhorst-Klug C, Rau G (1999) The recommendations for sensors and sensor placement procedures for surface electromyography. In: Hermens H, Freriks B, Merletti R, Stegeman D, Blok J, Rau G, Disselhorst-Klug C and Hägg G (eds) SENIAM—deliverable 8—European recommendations for surface electromyography. Roessingh Research and Development, Enschede, pp 15–54
go back to reference Garland SJ, Griffin L (1999) Motor unit double discharges: statistical anomaly or functional entity? Can J Appl Physiol 24(2):113–130 Garland SJ, Griffin L (1999) Motor unit double discharges: statistical anomaly or functional entity? Can J Appl Physiol 24(2):113–130
go back to reference Gerr F, Marcus M, Ensor C, Kleinbaum D, Cohen S, Edwards A, Gentry E, Ortiz DJ, Monteilh C (2002) A prospective study of computer users. 1. Study design and incidence of musculoskeletal symptoms and disorders. Am J Ind Med 41:221–235CrossRefPubMed Gerr F, Marcus M, Ensor C, Kleinbaum D, Cohen S, Edwards A, Gentry E, Ortiz DJ, Monteilh C (2002) A prospective study of computer users. 1. Study design and incidence of musculoskeletal symptoms and disorders. Am J Ind Med 41:221–235CrossRefPubMed
go back to reference Griffin L, Garland SJ, Ivanova T (1998) Discharge patterns in human motor units during fatiguing arm movements. J Appl Physiol 85(5):1684–1692 Griffin L, Garland SJ, Ivanova T (1998) Discharge patterns in human motor units during fatiguing arm movements. J Appl Physiol 85(5):1684–1692
go back to reference Gustafsson E, Hagberg M (2003) Computer mouse ue in two different hand positions: exposure, comfort, exertion and productivity. Int J Ind Ergonom 34:107–113 Gustafsson E, Hagberg M (2003) Computer mouse ue in two different hand positions: exposure, comfort, exertion and productivity. Int J Ind Ergonom 34:107–113
go back to reference Hägg GM (1991) Static work loads and occupational myalgia—a new explanation model. In: Anderson P A, Hobart DJ, Danoff JV (eds) Electromyographical kinesiology. Elsevier, Amsterdam, pp 141–143 Hägg GM (1991) Static work loads and occupational myalgia—a new explanation model. In: Anderson P A, Hobart DJ, Danoff JV (eds) Electromyographical kinesiology. Elsevier, Amsterdam, pp 141–143
go back to reference Henneman E, Somjen G, Carpenter DO (1965) Excitability and inhibitability of motoneurons of different sizes. J Neurophysiol 28:599–620PubMed Henneman E, Somjen G, Carpenter DO (1965) Excitability and inhibitability of motoneurons of different sizes. J Neurophysiol 28:599–620PubMed
go back to reference Jensen C, Borg V, Finsen L, Hansen K, Juul-Kristensen B, Christensen H (1998) Job demands, muscle activity and musculoskeletal symptoms in relation to work with the computer mouse. Scand J Work Environ Health 24(5):418–424 Jensen C, Borg V, Finsen L, Hansen K, Juul-Kristensen B, Christensen H (1998) Job demands, muscle activity and musculoskeletal symptoms in relation to work with the computer mouse. Scand J Work Environ Health 24(5):418–424
go back to reference Jensen C, Finsen L, Hansen K, Christensen H (1999) Upper trapezius muscle activity patterns during repetitive manual material handling and work with a computer mouse. J Electromyogr Kinesiol 9:317–325CrossRef Jensen C, Finsen L, Hansen K, Christensen H (1999) Upper trapezius muscle activity patterns during repetitive manual material handling and work with a computer mouse. J Electromyogr Kinesiol 9:317–325CrossRef
go back to reference Johnson P, McLoone H, Adams E, Arms S (2000a) Developing miniature force-sensing technologies for measuring the forces applied to a computer mouse. In: Proceedings of the 44th annual meeting of the human factors and Ergonomics society, vol 6. HFES, Santa Monica, pp 629–632 Johnson P, McLoone H, Adams E, Arms S (2000a) Developing miniature force-sensing technologies for measuring the forces applied to a computer mouse. In: Proceedings of the 44th annual meeting of the human factors and Ergonomics society, vol 6. HFES, Santa Monica, pp 629–632
go back to reference Johnson PW, Hagberg M, Wigaeus Hjelm E, Rempel D (2000b) Measuring and characterizing force exposures during computer mouse use. Scand J Work Environ Health 26(5):398–405 Johnson PW, Hagberg M, Wigaeus Hjelm E, Rempel D (2000b) Measuring and characterizing force exposures during computer mouse use. Scand J Work Environ Health 26(5):398–405
go back to reference Juul-Kristensen B, Kadefors R, Hansen K, Byström P, Sandsjö L, Sjøgaard G (2004) Clinical signs and physical function in neck and upper extremeties among elderly female computer users. The NEW-study. Eur J Appl Physiol (in press) Juul-Kristensen B, Kadefors R, Hansen K, Byström P, Sandsjö L, Sjøgaard G (2004) Clinical signs and physical function in neck and upper extremeties among elderly female computer users. The NEW-study. Eur J Appl Physiol (in press)
go back to reference Kadefors R, Läubli T (2002) Muscular disorders in computer users: introduction. Int J Ind Ergonom 30(4–5):203–210CrossRef Kadefors R, Läubli T (2002) Muscular disorders in computer users: introduction. Int J Ind Ergonom 30(4–5):203–210CrossRef
go back to reference Keen DA, Fuglevand AJ (2004) Distribution of motor unit force in human extensor digitorum assessed by spike-triggered averaging and intraneural microstimulation. J Neurophysiol 91:2515–2523 Keen DA, Fuglevand AJ (2004) Distribution of motor unit force in human extensor digitorum assessed by spike-triggered averaging and intraneural microstimulation. J Neurophysiol 91:2515–2523
go back to reference Kudina LP, Alexeeva NL (1992) Repetitive doublets of human motoneurones: analysis of interspike intervals and recruitment pattern. Electroencephalogr Clin Neurophysiol 85:243–247 Kudina LP, Alexeeva NL (1992) Repetitive doublets of human motoneurones: analysis of interspike intervals and recruitment pattern. Electroencephalogr Clin Neurophysiol 85:243–247
go back to reference Laursen B, Jensen BR (2000) Shoulder muscle activity in young and older people during a computer mouse task. Clin Biomech 15(1):S30–S33CrossRef Laursen B, Jensen BR (2000) Shoulder muscle activity in young and older people during a computer mouse task. Clin Biomech 15(1):S30–S33CrossRef
go back to reference Laursen B, Jensen BR, Ratkevicius A (2001) Performance and muscle activity during computer mouse tasks in young and elderly adults. Eur J Appl Physiol 84:329–336CrossRef Laursen B, Jensen BR, Ratkevicius A (2001) Performance and muscle activity during computer mouse tasks in young and elderly adults. Eur J Appl Physiol 84:329–336CrossRef
go back to reference Ljung B-O, Lieber RL, Fridén J (1999) Wrist extensor muscle pathology in lateral epicondylitis. J Hand Surg [Br] 24B(2):177–183 Ljung B-O, Lieber RL, Fridén J (1999) Wrist extensor muscle pathology in lateral epicondylitis. J Hand Surg [Br] 24B(2):177–183
go back to reference Mathiassen SE, Winkel J, Hägg GM (1995) Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies—a review. J Electromyogr Kinesiol 5(4):197–226CrossRef Mathiassen SE, Winkel J, Hägg GM (1995) Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies—a review. J Electromyogr Kinesiol 5(4):197–226CrossRef
go back to reference Mogk JPM, Keir PJ (2003) Crosstalk in surface electromyography of the proximal forearm during gripping tasks. J Electromyogr Kinesiol 13:63–71CrossRef Mogk JPM, Keir PJ (2003) Crosstalk in surface electromyography of the proximal forearm during gripping tasks. J Electromyogr Kinesiol 13:63–71CrossRef
go back to reference Moore KL (1985) The forearm of antebrachium. In: Clinically oriented anatomy, vol 2. Williams & Wilkins, Baltimore, pp 691–733 Moore KL (1985) The forearm of antebrachium. In: Clinically oriented anatomy, vol 2. Williams & Wilkins, Baltimore, pp 691–733
go back to reference Olsen HB, Blangsted AK, Søgaard K (2001) Motor unit firing behaviour in human trapezius muscle during double clicking of computer mouse. In: Sandsjö L, Kadefors R (eds) The 2nd PROCID symposium, prevention of muscle disorders in computer users: scientific basis and recommendations. National Institute for Working Life/West, Göteborg, pp 233–239 Olsen HB, Blangsted AK, Søgaard K (2001) Motor unit firing behaviour in human trapezius muscle during double clicking of computer mouse. In: Sandsjö L, Kadefors R (eds) The 2nd PROCID symposium, prevention of muscle disorders in computer users: scientific basis and recommendations. National Institute for Working Life/West, Göteborg, pp 233–239
go back to reference Olsen HB, Sjøgaard G, Farina D, Søgaard K (2002) Motor unit firing pattern during double and single clicking on a computer mouse. In: Kollmitzer J, Bijak M (eds) Standardization for better exchange of ideas. Proceedings of the 14th Congress of the International Society of Electrophysiology and Kinesiology. University of Vienna, Vienna, pp 321–322 Olsen HB, Sjøgaard G, Farina D, Søgaard K (2002) Motor unit firing pattern during double and single clicking on a computer mouse. In: Kollmitzer J, Bijak M (eds) Standardization for better exchange of ideas. Proceedings of the 14th Congress of the International Society of Electrophysiology and Kinesiology. University of Vienna, Vienna, pp 321–322
go back to reference Partanen VSJ, Lang AH (1978) An analysis of double discharges in the human elecromyogram. J Neurol Sci 36:363–375CrossRef Partanen VSJ, Lang AH (1978) An analysis of double discharges in the human elecromyogram. J Neurol Sci 36:363–375CrossRef
go back to reference Ranney D, Wells R, Moore A (1995) Upper limb musculoskeletal disorders in highly repetitive industries: precise anatomical physical findings. Ergonomics 38(7):1408–1423PubMed Ranney D, Wells R, Moore A (1995) Upper limb musculoskeletal disorders in highly repetitive industries: precise anatomical physical findings. Ergonomics 38(7):1408–1423PubMed
go back to reference Schnoz M, Läubli T, Weiss JA, Krueger H (1999) Activation of the finger and trapezius muscles in repetitive, short and long term finger movements. Z Arbeitswiss 53(2):131–138 Schnoz M, Läubli T, Weiss JA, Krueger H (1999) Activation of the finger and trapezius muscles in repetitive, short and long term finger movements. Z Arbeitswiss 53(2):131–138
go back to reference Sjøgaard G, Søgaard K, Finsen L, Olsen HB, Christensen H (2001) Doublets in motor unit activity of human forearm muscle during simulated computer work. Acta Physiol Pharmacol Bulg 26:83–85 Sjøgaard G, Søgaard K, Finsen L, Olsen HB, Christensen H (2001) Doublets in motor unit activity of human forearm muscle during simulated computer work. Acta Physiol Pharmacol Bulg 26:83–85
go back to reference Søgaard K, Sjøgaard G, Finsen L, Olsen HB, Christensen H (2001) Motor unit activity during stereotyped finger tasks and computer mouse work. J Electromyogr Kinesiol 11:197–206CrossRef Søgaard K, Sjøgaard G, Finsen L, Olsen HB, Christensen H (2001) Motor unit activity during stereotyped finger tasks and computer mouse work. J Electromyogr Kinesiol 11:197–206CrossRef
go back to reference Thorn S, Forsman M, Zhang Q, Hallbeck S (2002a) Motor unit firing pattern in the trapezius muscle during long-term computer work. In: Kollmitzer J, Bijak M (eds) Standardization for a better exchange of ideas. Proceedings of the 14th Congress of the International Society of Electrophysiology and Kinesiology. University of Vienna, Vienna, pp 34–35 Thorn S, Forsman M, Zhang Q, Hallbeck S (2002a) Motor unit firing pattern in the trapezius muscle during long-term computer work. In: Kollmitzer J, Bijak M (eds) Standardization for a better exchange of ideas. Proceedings of the 14th Congress of the International Society of Electrophysiology and Kinesiology. University of Vienna, Vienna, pp 34–35
go back to reference Thorn S, Forsman M, Zhang Q, Taoda K (2002b) Low-threshold motor unit activity during a 1-h static contraction in the trapezius muscle. Int J Ind Ergonom 30(4–5):225–236CrossRef Thorn S, Forsman M, Zhang Q, Taoda K (2002b) Low-threshold motor unit activity during a 1-h static contraction in the trapezius muscle. Int J Ind Ergonom 30(4–5):225–236CrossRef
go back to reference Waersted M, Eken T, Westgaard RH (1996) Activity of single motor units in attention-demanding tasks: firing pattern in the human trapezius muscle. Eur J Appl Physiol 72:323–329CrossRef Waersted M, Eken T, Westgaard RH (1996) Activity of single motor units in attention-demanding tasks: firing pattern in the human trapezius muscle. Eur J Appl Physiol 72:323–329CrossRef
go back to reference Wigaeus Tornqvist E, Eriksson N, Bergqvist U (2000) Dator- och kontorsarbetsplatsens fysiska och psykosociala arbetsmiljörisker. In: Marklund S (ed) Arbetsliv och hälsa. Arbetslivsinstitutet, Stockholm, pp 235–260 Wigaeus Tornqvist E, Eriksson N, Bergqvist U (2000) Dator- och kontorsarbetsplatsens fysiska och psykosociala arbetsmiljörisker. In: Marklund S (ed) Arbetsliv och hälsa. Arbetslivsinstitutet, Stockholm, pp 235–260
go back to reference Zennaro D, Läubli T, Krebs D, Klipstein A, Krueger H (2003) Continuous, intermitted and sporadic motor unit activity in the trapezius muscle during prolonged computer work. J Electromyogr Kinesiol 13:113–124CrossRefPubMed Zennaro D, Läubli T, Krebs D, Klipstein A, Krueger H (2003) Continuous, intermitted and sporadic motor unit activity in the trapezius muscle during prolonged computer work. J Electromyogr Kinesiol 13:113–124CrossRefPubMed
Metadata
Title
A comparison of muscular activity during single and double mouse clicks
Authors
Stefan Thorn
Mikael Forsman
Susan Hallbeck
Publication date
01-05-2005
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 1-2/2005
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-004-1312-1

Other articles of this Issue 1-2/2005

European Journal of Applied Physiology 1-2/2005 Go to the issue