Abstract

Background

Both calliper devices and digital photographic methods have been used to quantify foot arch height parameters. The purpose of this study was to compare the reliability of both a calliper device and digital photographic method in determining the arch height index (AHI).

Methods

Twenty subjects underwent measurements of AHI on two separate days. On each day, AHI measurements during both sitting and standing were taken using the AHIMS and digital photographic methods by the same single tester. The intra-tester reliability of each measurement technique was assessed using intraclass correlation coefficients (ICC) and standard error of measurement (SEM). Additionally, the relationship between AHI measurements derived from the two different methods was assessed using a correlation analysis.

Results

The reliability for both the AHIMS and digital photographic methods was excellent with ICC values exceeding 0.86 and SEM values of less than 0.009 for the AHI. Moreover, the reliability of both measurement techniques was equivalent. There was a strong positive correlation between the AHI values collected using both methods. AHI values calculated using the digital photographic method tended to be greater than those derived using the AHIMS.

Conclusion

Digital photographic methods offer equivalent intra-tester reliability to previously established calliper methods when assessing AHI. While AHI measurements calculated using both methods were highly related, the greater AHI values in the photographic method implied caution should be exercised when comparing absolute values between the two methods. Future studies are required to determine whether digital photographic methods can be developed with improved validity.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kaufman KR, Brodine SK, Shaffer RA, Johnson CW, Cullison TR: The effect of foot structure and range of motion on musculoskeletal overuse injuries. American Journal of Sports Medicine. 1999, 27: 585-593.PubMed Kaufman KR, Brodine SK, Shaffer RA, Johnson CW, Cullison TR: The effect of foot structure and range of motion on musculoskeletal overuse injuries. American Journal of Sports Medicine. 1999, 27: 585-593.PubMed
2.
go back to reference Williams DS, McClay IS, Hamill J: Arch structure and injury patterns in runners. Clinical Biomechanics. 2001, 16: 341-347. 10.1016/S0268-0033(01)00005-5.PubMed Williams DS, McClay IS, Hamill J: Arch structure and injury patterns in runners. Clinical Biomechanics. 2001, 16: 341-347. 10.1016/S0268-0033(01)00005-5.PubMed
3.
go back to reference Pohl MB, Rabbito M, Ferber R: The role of tibialis posterior fatigue on foot kinematics during walking. J Foot Ankle Res. 2010, 3: 6-10.1186/1757-1146-3-6.PubMedPubMedCentral Pohl MB, Rabbito M, Ferber R: The role of tibialis posterior fatigue on foot kinematics during walking. J Foot Ankle Res. 2010, 3: 6-10.1186/1757-1146-3-6.PubMedPubMedCentral
4.
go back to reference Cobb SC, Tis LL, Johnson JT, Wang Y, Geil MD, McCarty FA: The effect of low-mobile foot posture on multi-segment medial foot model gait kinematics. Gait & Posture. 2009, 30: 334-339. Cobb SC, Tis LL, Johnson JT, Wang Y, Geil MD, McCarty FA: The effect of low-mobile foot posture on multi-segment medial foot model gait kinematics. Gait & Posture. 2009, 30: 334-339.
5.
go back to reference McPoil TG, Cornwall MW, Medoff L, Vincenzino B, Forsberg K, Hilz D: Arch height change during sit-to-stand: an alternative for the navicular drop test. J Foot Ankle Res. 2008, 1: 3-10.1186/1757-1146-1-3.PubMedPubMedCentral McPoil TG, Cornwall MW, Medoff L, Vincenzino B, Forsberg K, Hilz D: Arch height change during sit-to-stand: an alternative for the navicular drop test. J Foot Ankle Res. 2008, 1: 3-10.1186/1757-1146-1-3.PubMedPubMedCentral
6.
go back to reference Williams DS, McClay IS: Measurements used to characterize the foot and the medial longitudinal arch: Reliability and validity. Physical Therapy. 2000, 80: 864-871.PubMed Williams DS, McClay IS: Measurements used to characterize the foot and the medial longitudinal arch: Reliability and validity. Physical Therapy. 2000, 80: 864-871.PubMed
7.
go back to reference Zifchock RA, Davis I, Hillstrom H, Song JS: The effect of gender, age, and lateral dominance on arch height and arch stiffness. Foot & Ankle International. 2006, 27: 367-372. Zifchock RA, Davis I, Hillstrom H, Song JS: The effect of gender, age, and lateral dominance on arch height and arch stiffness. Foot & Ankle International. 2006, 27: 367-372.
8.
go back to reference Butler RJ, Hillstrom H, Song J, Richards CJ, Davis IS: Arch height index measurement system - Establishment of reliability and normative values. Journal of the American Podiatric Medical Association. 2008, 98: 102-106.PubMed Butler RJ, Hillstrom H, Song J, Richards CJ, Davis IS: Arch height index measurement system - Establishment of reliability and normative values. Journal of the American Podiatric Medical Association. 2008, 98: 102-106.PubMed
9.
go back to reference Richards CJ, Card K, Song J, Hillstrom H, Butler R, Davis I: A novel arch height index measurement system (AHIMS): intra- and inter-rater reliability. Proceedings of American Society of Biomechanics Annual Meeting Toledo. 2003 Richards CJ, Card K, Song J, Hillstrom H, Butler R, Davis I: A novel arch height index measurement system (AHIMS): intra- and inter-rater reliability. Proceedings of American Society of Biomechanics Annual Meeting Toledo. 2003
10.
go back to reference McGinley JL, Baker R, Wolfe R, Morris ME: The reliability of three-dimensional kinematic gait measurements: A systematic review. Gait & Posture. 2009, 29: 360-369. McGinley JL, Baker R, Wolfe R, Morris ME: The reliability of three-dimensional kinematic gait measurements: A systematic review. Gait & Posture. 2009, 29: 360-369.
11.
go back to reference Shrout PE, Fleiss JL: Intraclass correlations - uses in assessing rater reliability. Psychological Bulletin. 1979, 86: 420-428. 10.1037/0033-2909.86.2.420.PubMed Shrout PE, Fleiss JL: Intraclass correlations - uses in assessing rater reliability. Psychological Bulletin. 1979, 86: 420-428. 10.1037/0033-2909.86.2.420.PubMed
12.
go back to reference Portney LG, Watkins MP: Foundations of Clinical Research: Applications to Practice. 2000, Upper Saddle River: Prentice-Hall, Inc, Second Portney LG, Watkins MP: Foundations of Clinical Research: Applications to Practice. 2000, Upper Saddle River: Prentice-Hall, Inc, Second
Metadata
Title
A comparison of foot arch measurement reliability using both digital photography and calliper methods
Authors
Michael B Pohl
Lindsay Farr
Publication date
01-12-2010
Publisher
BioMed Central
Published in
Journal of Foot and Ankle Research / Issue 1/2010
Electronic ISSN: 1757-1146
DOI
https://doi.org/10.1186/1757-1146-3-14

Other articles of this Issue 1/2010

Journal of Foot and Ankle Research 1/2010 Go to the issue