Skip to main content
Top
Published in: General Thoracic and Cardiovascular Surgery 7/2012

01-07-2012 | Case Report

A case of ascending aortic pseudoaneurysm in a patient with aortic replacement

Authors: Yuichi Ishida, Yasuhito Sakano, Shin-ichi Ohki, Arata Muraoka, Kei Aizawa, Yoshio Misawa

Published in: General Thoracic and Cardiovascular Surgery | Issue 7/2012

Login to get access

Abstract

A 59-year-old man with a history of ascending aorta replacement for an aortic dissection using gelatin–resorcin–formalin glue at age of 50 years presented with paroxysmal nocturnal dyspnea. An echocardiogram showed severe aortic regurgitation associated with aortic root enlargement. Chest computed tomography showed that the ascending aorta was dilated and a pseudoaneurysm was observed around the implanted prosthetic graft. Upon opening the ascending aorta, we found that the posterior wall of the proximal anastomotic portion of the implanted graft was ruptured. After replacement of the aortic root with a composite graft and reconstruction of the orifices of the right and left coronary arteries, total arch replacement by the separated graft technique was performed. The postoperative course was uneventful.
Literature
1.
go back to reference Di Eusanio M, Schepens MA, Morshuis WJ, Dossche KM, Kazui T, Ohkura K, et al. Separate grafts or en bloc anastomosis for arch vessels reimplantation to the aortic arch. Ann Thorac Surg. 2004;77:2021–8.CrossRefPubMed Di Eusanio M, Schepens MA, Morshuis WJ, Dossche KM, Kazui T, Ohkura K, et al. Separate grafts or en bloc anastomosis for arch vessels reimplantation to the aortic arch. Ann Thorac Surg. 2004;77:2021–8.CrossRefPubMed
2.
go back to reference Bachet J, Goudot B, Dreyfus G, Banfi C, Ayle NA, Aota M, et al. The proper use of glue: a 20-year experience with the GRF glue in acute aortic dissection. J Card Surg. 1997;12:243–53.CrossRefPubMed Bachet J, Goudot B, Dreyfus G, Banfi C, Ayle NA, Aota M, et al. The proper use of glue: a 20-year experience with the GRF glue in acute aortic dissection. J Card Surg. 1997;12:243–53.CrossRefPubMed
3.
go back to reference Fukunaga S, Karck M, Harringer W, Cremer J, Rhein C, Haverich A. The use of gelatin–resorcin–formalin glue in acute aortic dissection type A. Eur J Cardiothorac Surg. 1999;15:564–9.CrossRefPubMed Fukunaga S, Karck M, Harringer W, Cremer J, Rhein C, Haverich A. The use of gelatin–resorcin–formalin glue in acute aortic dissection type A. Eur J Cardiothorac Surg. 1999;15:564–9.CrossRefPubMed
4.
go back to reference Kazui T, Washiyama N, Bashar AH, Terada H, Suzuki K, Yamashita K, et al. Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root. Ann Thorac Surg. 2001;72:509–14.CrossRefPubMed Kazui T, Washiyama N, Bashar AH, Terada H, Suzuki K, Yamashita K, et al. Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root. Ann Thorac Surg. 2001;72:509–14.CrossRefPubMed
5.
go back to reference Witter K, Tonar Z, Matejka VM, Martinca T, Jonak M, Rokosny S, et al. Tissue reaction to three different types of tissue glues in an experimental aorta dissection model: a quantitative approach. Histochem Cell Biol. 2010;133:241–59.CrossRefPubMed Witter K, Tonar Z, Matejka VM, Martinca T, Jonak M, Rokosny S, et al. Tissue reaction to three different types of tissue glues in an experimental aorta dissection model: a quantitative approach. Histochem Cell Biol. 2010;133:241–59.CrossRefPubMed
6.
go back to reference Shiono M. Surgery for acute aortic dissection using gelatin–resorcin–formalin glue: perspective from 10 years of follow-up at a single center. J Artif Organs. 2008;11:19–23.CrossRefPubMed Shiono M. Surgery for acute aortic dissection using gelatin–resorcin–formalin glue: perspective from 10 years of follow-up at a single center. J Artif Organs. 2008;11:19–23.CrossRefPubMed
7.
go back to reference Kunihara T, Shiiya N, Matsuzaki K, Murashita T, Matsui Y. Recommendation for appropriate use of GRF glue in the operation for acute aortic dissection. Ann Thorac Cardiovasc Surg. 2008;14:88–95.PubMed Kunihara T, Shiiya N, Matsuzaki K, Murashita T, Matsui Y. Recommendation for appropriate use of GRF glue in the operation for acute aortic dissection. Ann Thorac Cardiovasc Surg. 2008;14:88–95.PubMed
8.
go back to reference Kunihara T, Iizuka K, Sasaki S, Shiiya N, Sata F, Matsui Y. Optimal proportions of gelatin–resorcin–formalin components in aortic surgery. Eur J Cardiothorac Surg. 2009;36:962–6.CrossRefPubMed Kunihara T, Iizuka K, Sasaki S, Shiiya N, Sata F, Matsui Y. Optimal proportions of gelatin–resorcin–formalin components in aortic surgery. Eur J Cardiothorac Surg. 2009;36:962–6.CrossRefPubMed
9.
go back to reference Shiono M, Hata M, Sezai A, Niino T, Yagi S, Negishi N. Late results of gelatin–resorcin–formalin glue-aided repair in acute type A aortic dissection. Artif Organs. 2006;30:962–5.CrossRefPubMed Shiono M, Hata M, Sezai A, Niino T, Yagi S, Negishi N. Late results of gelatin–resorcin–formalin glue-aided repair in acute type A aortic dissection. Artif Organs. 2006;30:962–5.CrossRefPubMed
Metadata
Title
A case of ascending aortic pseudoaneurysm in a patient with aortic replacement
Authors
Yuichi Ishida
Yasuhito Sakano
Shin-ichi Ohki
Arata Muraoka
Kei Aizawa
Yoshio Misawa
Publication date
01-07-2012
Publisher
Springer Japan
Published in
General Thoracic and Cardiovascular Surgery / Issue 7/2012
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-012-0022-6

Other articles of this Issue 7/2012

General Thoracic and Cardiovascular Surgery 7/2012 Go to the issue