We propose a planning method to design true 4-dimensional (4D) intensity-modulated radiotherapy (IMRT) plans, called the t4Dplan method, in which the planning target volume (PTV) of the individual phases of the 4D computed tomography (CT) and the conventional PTV receive non-uniform doses but the cumulative dose to the PTV of each phase, computed using deformable image registration (DIR), are uniform. The non-uniform dose prescription for the conventional PTV was obtained by solving linear equations that required motion-convolved 4D dose to be uniform to the PTV for the end-exhalation phase (PTV50) and by constraining maximum inhomogeneity to 20%. A plug-in code to the treatment planning system was developed to perform the IMRT optimization based on this non-uniform PTV dose prescription. The 4D dose was obtained by summing the mapped doses from individual phases of the 4D CT using DIR. This 4D dose distribution was compared with that of the internal target volume (ITV) method. The robustness of the 4D plans over the course of radiotherapy was evaluated by computing the 4D dose distributions on repeat 4D CT datasets. Three patients with lung tumors were selected to demonstrate the advantages of the t4Dplan method compared with the commonly used ITV method. The 4D dose distribution using the t4Dplan method resulted in greater normal tissue sparing (such as lung, stomach, liver and heart) than did plans designed using the ITV method. The dose volume histograms of cumulative 4D doses to the PTV50, clinical target volume, lung, spinal cord, liver, and heart on the 4D repeat CTs for the two patients were similar to those for the 4D dose at the time of original planning.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rietzel E, Chen GTY, Choi NC, Willet CG: Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. International Journal of Radiation Oncology Biology Physics 2005, 61: 1535-1550. 10.1016/j.ijrobp.2004.11.037CrossRef Rietzel E, Chen GTY, Choi NC, Willet CG: Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. International Journal of Radiation Oncology Biology Physics 2005, 61: 1535-1550. 10.1016/j.ijrobp.2004.11.037CrossRef
2.
go back to reference Keall P: 4-dimensional computed tomography imaging and treatment planning. Seminars in Radiation Oncology 2004, 14: 81-90. 10.1053/j.semradonc.2003.10.006CrossRefPubMed Keall P: 4-dimensional computed tomography imaging and treatment planning. Seminars in Radiation Oncology 2004, 14: 81-90. 10.1053/j.semradonc.2003.10.006CrossRefPubMed
3.
go back to reference Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, et al.: The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Medical Physics 2006, 33: 3874-3900. 10.1118/1.2349696CrossRefPubMed Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, et al.: The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Medical Physics 2006, 33: 3874-3900. 10.1118/1.2349696CrossRefPubMed
4.
go back to reference Low DA, Nystrom M, Kalinin E, Parikh P, Dempsey JF, Bradley JD, Mutic S, Wahab SH, Islam T, Christensen G, et al.: A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Medical Physics 2003, 30: 1254-1263. 10.1118/1.1576230CrossRefPubMed Low DA, Nystrom M, Kalinin E, Parikh P, Dempsey JF, Bradley JD, Mutic S, Wahab SH, Islam T, Christensen G, et al.: A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Medical Physics 2003, 30: 1254-1263. 10.1118/1.1576230CrossRefPubMed
5.
go back to reference Mageras GS, Pevsner A, Yorke ED, Rosenzweig KE, Ford EC, Hertanto A, Larson SM, Lovelock DM, Erdi YE, Nehmeh SA, et al.: Measurement of lung tumor motion using respiration-correlated CT. International Journal of Radiation Oncology Biology Physics 2004, 60: 933-941.CrossRef Mageras GS, Pevsner A, Yorke ED, Rosenzweig KE, Ford EC, Hertanto A, Larson SM, Lovelock DM, Erdi YE, Nehmeh SA, et al.: Measurement of lung tumor motion using respiration-correlated CT. International Journal of Radiation Oncology Biology Physics 2004, 60: 933-941.CrossRef
6.
go back to reference Trofimov A, Rietzel E, Lu HM, Martin B, Jiang S, Chen GTY, Bortfeld T: Temporo-spatial IMRT optimization: concepts, implementation and initial results. Physics in Medicine and Biology 2005, 50: 2779-2798. 10.1088/0031-9155/50/12/004CrossRefPubMed Trofimov A, Rietzel E, Lu HM, Martin B, Jiang S, Chen GTY, Bortfeld T: Temporo-spatial IMRT optimization: concepts, implementation and initial results. Physics in Medicine and Biology 2005, 50: 2779-2798. 10.1088/0031-9155/50/12/004CrossRefPubMed
7.
go back to reference Werner R, Ehrhardt J, Frenzel T, Saring D, Lu W, Low D, Handels H: Motion artifact reducing reconstruction of 4D CT image data for the analysis of respiratory dynamics. Methods of Information in Medicine 2007, 46: 254-260.PubMed Werner R, Ehrhardt J, Frenzel T, Saring D, Lu W, Low D, Handels H: Motion artifact reducing reconstruction of 4D CT image data for the analysis of respiratory dynamics. Methods of Information in Medicine 2007, 46: 254-260.PubMed
8.
go back to reference Wolthaus JWH, Schneider C, Sonke JJ, van Herk M, Belderbos JSA, Rossi MMG, Lebesque JV, Damen EMF: Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. International Journal of Radiation Oncology Biology Physics 2006, 65: 1560-1571. 10.1016/j.ijrobp.2006.04.031CrossRef Wolthaus JWH, Schneider C, Sonke JJ, van Herk M, Belderbos JSA, Rossi MMG, Lebesque JV, Damen EMF: Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. International Journal of Radiation Oncology Biology Physics 2006, 65: 1560-1571. 10.1016/j.ijrobp.2006.04.031CrossRef
9.
go back to reference Yamamoto T, Langner U, Loo BW, Shen J, Keall PJ: Retrospective Analysis of Artifacts in Four-Dimensional CT Images of 50 Abdominal and Thoracic Radiotherapy Patients. International Journal of Radiation Oncology Biology Physics 2008, 72: 1250-1258. 10.1016/j.ijrobp.2008.06.1937CrossRef Yamamoto T, Langner U, Loo BW, Shen J, Keall PJ: Retrospective Analysis of Artifacts in Four-Dimensional CT Images of 50 Abdominal and Thoracic Radiotherapy Patients. International Journal of Radiation Oncology Biology Physics 2008, 72: 1250-1258. 10.1016/j.ijrobp.2008.06.1937CrossRef
10.
go back to reference Kang YX, Zhang XD, Chang JY, Wang H, Wei X, Liao ZX, Komaki R, Cox JD, Balter PA, Liu H, et al.: 4D proton treatment planning strategy for mobile lung tumors. International Journal of Radiation Oncology Biology Physics 2007, 67: 906-914. 10.1016/j.ijrobp.2006.10.045CrossRef Kang YX, Zhang XD, Chang JY, Wang H, Wei X, Liao ZX, Komaki R, Cox JD, Balter PA, Liu H, et al.: 4D proton treatment planning strategy for mobile lung tumors. International Journal of Radiation Oncology Biology Physics 2007, 67: 906-914. 10.1016/j.ijrobp.2006.10.045CrossRef
11.
go back to reference Shimizu S, Shirato H, Ogura S, Akita-Dosaka H, Kitamura K, Nishioka T, Kagei K, Nishimura M, Miyasaka K: Detection of lung tumor movement in real-time tumor-tracking radiotherapy. International Journal of Radiation Oncology Biology Physics 2001, 51: 304-310.CrossRef Shimizu S, Shirato H, Ogura S, Akita-Dosaka H, Kitamura K, Nishioka T, Kagei K, Nishimura M, Miyasaka K: Detection of lung tumor movement in real-time tumor-tracking radiotherapy. International Journal of Radiation Oncology Biology Physics 2001, 51: 304-310.CrossRef
12.
go back to reference Remouchamps VM, Vicini FA, Sharpe MB, Kestin LL, Martinez AA, Wong JW: Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. International Journal of Radiation Oncology Biology Physics 2003, 55: 392-406. 10.1016/S0360-3016(02)04143-3CrossRef Remouchamps VM, Vicini FA, Sharpe MB, Kestin LL, Martinez AA, Wong JW: Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. International Journal of Radiation Oncology Biology Physics 2003, 55: 392-406. 10.1016/S0360-3016(02)04143-3CrossRef
13.
go back to reference Yorke ED, Wang L, Rosenzweig KE, Mah D, Paoli JB, Chui CS: Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation. International Journal of Radiation Oncology Biology Physics 2002, 53: 1058-1070. 10.1016/S0360-3016(02)02778-5CrossRef Yorke ED, Wang L, Rosenzweig KE, Mah D, Paoli JB, Chui CS: Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation. International Journal of Radiation Oncology Biology Physics 2002, 53: 1058-1070. 10.1016/S0360-3016(02)02778-5CrossRef
14.
go back to reference Suh YL, Weiss E, Zhong HL, Fatyga M, Siebers JV, Keall PJ: A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery. International Journal of Radiation Oncology Biology Physics 2008, 71: 1526-1536. 10.1016/j.ijrobp.2008.04.018CrossRef Suh YL, Weiss E, Zhong HL, Fatyga M, Siebers JV, Keall PJ: A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery. International Journal of Radiation Oncology Biology Physics 2008, 71: 1526-1536. 10.1016/j.ijrobp.2008.04.018CrossRef
15.
go back to reference Suh YL, Sawant A, Venkat R, Keall PJ: Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm. Physics in Medicine and Biology 2009, 54: 3821-3835. 10.1088/0031-9155/54/12/014CrossRefPubMed Suh YL, Sawant A, Venkat R, Keall PJ: Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm. Physics in Medicine and Biology 2009, 54: 3821-3835. 10.1088/0031-9155/54/12/014CrossRefPubMed
16.
go back to reference Gui MZ, Feng YM, Yi BY, Dhople AA, Yu C: Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method. Medical Physics 2010, 37: 1966-1975. 10.1118/1.3319498PubMedCentralCrossRefPubMed Gui MZ, Feng YM, Yi BY, Dhople AA, Yu C: Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method. Medical Physics 2010, 37: 1966-1975. 10.1118/1.3319498PubMedCentralCrossRefPubMed
17.
go back to reference Rosu M, Balter JM, Chetty IJ, Kessler ML, McShan DL, Balter P, Ten Haken RK: How extensive of a 4D dataset is needed to estimate cumulative dose distribution plan evaluation metrics in conformal lung therapy? Medical Physics 2007, 34: 233-245. 10.1118/1.2400624CrossRefPubMed Rosu M, Balter JM, Chetty IJ, Kessler ML, McShan DL, Balter P, Ten Haken RK: How extensive of a 4D dataset is needed to estimate cumulative dose distribution plan evaluation metrics in conformal lung therapy? Medical Physics 2007, 34: 233-245. 10.1118/1.2400624CrossRefPubMed
18.
go back to reference Lujan AE, Larsen EW, Balter JM, Ten Haken RK: A method for incorporating organ motion due to breathing into 3D dose calculations. Medical Physics 1999, 26: 715-720. 10.1118/1.598577CrossRefPubMed Lujan AE, Larsen EW, Balter JM, Ten Haken RK: A method for incorporating organ motion due to breathing into 3D dose calculations. Medical Physics 1999, 26: 715-720. 10.1118/1.598577CrossRefPubMed
19.
go back to reference Zhu L, Lee L, Ma YZ, Ye YY, Mazzeo R, Xing L: Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments. Physics in Medicine and Biology 2008, 53: 6653-6672. 10.1088/0031-9155/53/23/002CrossRefPubMed Zhu L, Lee L, Ma YZ, Ye YY, Mazzeo R, Xing L: Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments. Physics in Medicine and Biology 2008, 53: 6653-6672. 10.1088/0031-9155/53/23/002CrossRefPubMed
20.
go back to reference Pan T, Lee TY, Rietzel E, Chen GTY: 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Medical Physics 2004, 31: 333-340. 10.1118/1.1639993CrossRefPubMed Pan T, Lee TY, Rietzel E, Chen GTY: 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Medical Physics 2004, 31: 333-340. 10.1118/1.1639993CrossRefPubMed
21.
go back to reference Chang JY, Zhang XD, Wang XC, Kang YX, Riley B, Bilton S, Mohan R, Komaki R, Cox JD: Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer. International Journal of Radiation Oncology Biology Physics 2006, 65: 1087-1096. 10.1016/j.ijrobp.2006.01.052CrossRef Chang JY, Zhang XD, Wang XC, Kang YX, Riley B, Bilton S, Mohan R, Komaki R, Cox JD: Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer. International Journal of Radiation Oncology Biology Physics 2006, 65: 1087-1096. 10.1016/j.ijrobp.2006.01.052CrossRef
22.
go back to reference Feuvret L, Noel G, Mazeron JJ, Bey P: Conformity index: A review. International Journal of Radiation Oncology Biology Physics 2006, 64: 333-342. 10.1016/j.ijrobp.2005.09.028CrossRef Feuvret L, Noel G, Mazeron JJ, Bey P: Conformity index: A review. International Journal of Radiation Oncology Biology Physics 2006, 64: 333-342. 10.1016/j.ijrobp.2005.09.028CrossRef
23.
go back to reference Li X, Zhang PP, Mah D, Gewanter R, Kutcher G: Novel lung IMRT planning algorithms with nonuniform dose delivery strategy to account for respiratory motion. Medical Physics 2006, 33: 3390-3398. 10.1118/1.2335485CrossRefPubMed Li X, Zhang PP, Mah D, Gewanter R, Kutcher G: Novel lung IMRT planning algorithms with nonuniform dose delivery strategy to account for respiratory motion. Medical Physics 2006, 33: 3390-3398. 10.1118/1.2335485CrossRefPubMed
24.
go back to reference Wolthaus JWH, Sonke JJ, van Herk M, Belderbos JSA, Rossi MMG, Lebesque JV, Damen EMF: Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. International Journal of Radiation Oncology Biology Physics 2008, 70: 1229-1238. 10.1016/j.ijrobp.2007.11.042CrossRef Wolthaus JWH, Sonke JJ, van Herk M, Belderbos JSA, Rossi MMG, Lebesque JV, Damen EMF: Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. International Journal of Radiation Oncology Biology Physics 2008, 70: 1229-1238. 10.1016/j.ijrobp.2007.11.042CrossRef
25.
go back to reference Cuijpers JP, Verbakel W, Slotman BJ, Senan S: A novel simple approach for incorporation of respiratory motion in stereotactic treatments of lung tumors. Radiotherapy and Oncology 2010, 97: 443-448. 10.1016/j.radonc.2010.06.007CrossRefPubMed Cuijpers JP, Verbakel W, Slotman BJ, Senan S: A novel simple approach for incorporation of respiratory motion in stereotactic treatments of lung tumors. Radiotherapy and Oncology 2010, 97: 443-448. 10.1016/j.radonc.2010.06.007CrossRefPubMed
26.
go back to reference Guckenberger M, Kavanagh A, Webb S, Brada M: A novel respiratory motion compensation strategy combining gated beam delivery and mean target position concept - A compromise between small safety margins and long duty cycles. Radiotherapy and Oncology 2011, 98: 317-322. 10.1016/j.radonc.2011.01.008CrossRefPubMed Guckenberger M, Kavanagh A, Webb S, Brada M: A novel respiratory motion compensation strategy combining gated beam delivery and mean target position concept - A compromise between small safety margins and long duty cycles. Radiotherapy and Oncology 2011, 98: 317-322. 10.1016/j.radonc.2011.01.008CrossRefPubMed
27.
go back to reference Ling CC, Humm J, Larson S, Amols H, Fuks Z, Leibel S, Koutcher JA: Towards multidimensional radiotherapy (MD-CRT): Biological imaging and biological conformality. International Journal of Radiation Oncology Biology Physics 2000, 47: 551-560. 10.1016/S0360-3016(00)00467-3CrossRef Ling CC, Humm J, Larson S, Amols H, Fuks Z, Leibel S, Koutcher JA: Towards multidimensional radiotherapy (MD-CRT): Biological imaging and biological conformality. International Journal of Radiation Oncology Biology Physics 2000, 47: 551-560. 10.1016/S0360-3016(00)00467-3CrossRef
28.
go back to reference Alber M, Paulsen F, Eschmann SM, Machulla HJ: On biologically conformal boost dose optimization. Physics in Medicine and Biology 2003, 48: N31-N35. 10.1088/0031-9155/48/2/404CrossRefPubMed Alber M, Paulsen F, Eschmann SM, Machulla HJ: On biologically conformal boost dose optimization. Physics in Medicine and Biology 2003, 48: N31-N35. 10.1088/0031-9155/48/2/404CrossRefPubMed
29.
go back to reference Bentzen SM: Theragnostic imaging for radiation oncology: dose-painting by numbers. Lancet Oncology 2005, 6: 112-117. 10.1016/S1470-2045(05)01737-7CrossRefPubMed Bentzen SM: Theragnostic imaging for radiation oncology: dose-painting by numbers. Lancet Oncology 2005, 6: 112-117. 10.1016/S1470-2045(05)01737-7CrossRefPubMed
30.
go back to reference Flynn RT, Bowen SR, Bentzen SM, Mackie TR, Jeraj R: Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting. Physics in Medicine and Biology 2008, 53: 4153-4167. 10.1088/0031-9155/53/15/010PubMedCentralCrossRefPubMed Flynn RT, Bowen SR, Bentzen SM, Mackie TR, Jeraj R: Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting. Physics in Medicine and Biology 2008, 53: 4153-4167. 10.1088/0031-9155/53/15/010PubMedCentralCrossRefPubMed
31.
go back to reference Thorwarth D, Eschmann SM, Paulsen F, Alber M: Hypoxia dose painting by numbers: A planning study. International Journal of Radiation Oncology Biology Physics 2007, 68: 291-300. 10.1016/j.ijrobp.2006.11.061CrossRef Thorwarth D, Eschmann SM, Paulsen F, Alber M: Hypoxia dose painting by numbers: A planning study. International Journal of Radiation Oncology Biology Physics 2007, 68: 291-300. 10.1016/j.ijrobp.2006.11.061CrossRef
32.
go back to reference Thorwarth D, Soukup M, Atber M: Dose painting with IMPT, helical tomotherapy and IMXT: A dosimetric comparison. Radiotherapy and Oncology 2008, 86: 30-34. 10.1016/j.radonc.2007.11.003CrossRefPubMed Thorwarth D, Soukup M, Atber M: Dose painting with IMPT, helical tomotherapy and IMXT: A dosimetric comparison. Radiotherapy and Oncology 2008, 86: 30-34. 10.1016/j.radonc.2007.11.003CrossRefPubMed
33.
34.
go back to reference Barnes EIA, Murray BR, Robinson DM, Underwood LJ, Hanson J, Roa WHY: Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration. International Journal of Radiation Oncology Biology Physics 2001, 50: 1091-1098. 10.1016/S0360-3016(01)01592-9CrossRef Barnes EIA, Murray BR, Robinson DM, Underwood LJ, Hanson J, Roa WHY: Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration. International Journal of Radiation Oncology Biology Physics 2001, 50: 1091-1098. 10.1016/S0360-3016(01)01592-9CrossRef
35.
go back to reference Engelsman M, Sharp GC, Bortfeld T, Onimaru R, Shirato H: How much margin reduction is possible through gating or breath hold? Physics in Medicine and Biology 2005, 50: 477-490. 10.1088/0031-9155/50/3/006CrossRefPubMed Engelsman M, Sharp GC, Bortfeld T, Onimaru R, Shirato H: How much margin reduction is possible through gating or breath hold? Physics in Medicine and Biology 2005, 50: 477-490. 10.1088/0031-9155/50/3/006CrossRefPubMed
Metadata
Title
A 4D IMRT planning method using deformable image registration to improve normal tissue sparing with contemporary delivery techniques
Authors
Xiaoqiang Li
Xiaochun Wang
Yupeng Li
Xiaodong Zhang
Publication date
01-12-2011
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2011
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-6-83

Other articles of this Issue 1/2011

Radiation Oncology 1/2011 Go to the issue