Abstract

Purpose

The diagnosis of osteomyelitis is a challenge for diagnostic imaging. Nuclear medicine procedures including white blood cell imaging have been successfully used for the identification of bone infections. This multinational, phase III clinical study in 22 European centres was undertaken to compare anti-granulocyte imaging using the murine IgG antibody besilesomab (Scintimun®) with 99mTc-labelled white blood cells in patients with peripheral osteomyelitis.

Methods

A total of 119 patients with suspected osteomyelitis of the peripheral skeleton received 99mTc-besilesomab and 99mTc-hexamethylpropyleneamine oxime (HMPAO)-labelled white blood cells (WBCs) in random order 2–4 days apart. Planar images were acquired at 4 and 24 h after injection. All scintigraphic images were interpreted in an off-site blinded read by three experienced physicians specialized in nuclear medicine, followed by a fourth blinded reader for adjudication. In addition, clinical follow-up information was collected and a final diagnosis was provided by the investigators and an independent truth panel. Safety data including levels of human anti-mouse antibodies (HAMA) and vital signs were recorded.

Results

The agreement in diagnosis across all three readers between Scintimun® and 99mTc-HMPAO-labelled WBCs was 0.83 (lower limit of the 95% confidence interval 0.8). Using the final diagnosis of the local investigator as a reference, Scintimun® had higher sensitivity than 99mTc-HMPAO-labelled WBCs (74.8 vs 59.0%) at slightly lower specificity (71.8 vs 79.5%, respectively). All parameters related to patient safety (laboratory data, vital signs) did not provide evidence of an elevated risk associated with the use of Scintimun® except for two cases of transient hypotension. HAMA were detected in 16 of 116 patients after scan (13.8%).

Conclusion

Scintimun® imaging is accurate, efficacious and safe in the diagnosis of peripheral bone infections and provides comparable information to 99mTc-HMPAO-labelled WBCs.
Appendix
Available only for authorised users
Literature
1.
go back to reference Concia E, Prandini N, Massari L, Ghisellini F, Consoli V, Menichetti F, et al. Osteomyelitis: clinical update for practical guidelines. Nucl Med Commun 2006;27:645–60.PubMedCrossRef Concia E, Prandini N, Massari L, Ghisellini F, Consoli V, Menichetti F, et al. Osteomyelitis: clinical update for practical guidelines. Nucl Med Commun 2006;27:645–60.PubMedCrossRef
2.
go back to reference Love C, Marwin SE, Palestro CJ. Nuclear medicine and the infected joint replacement. Semin Nucl Med 2009;39:66–78.PubMedCrossRef Love C, Marwin SE, Palestro CJ. Nuclear medicine and the infected joint replacement. Semin Nucl Med 2009;39:66–78.PubMedCrossRef
3.
go back to reference Chatha DS, Cunningham PM, Schweitzer ME. MR imaging of the diabetic foot: diagnostic challenges. Radiol Clin North Am 2005;43:747–59. ix.PubMedCrossRef Chatha DS, Cunningham PM, Schweitzer ME. MR imaging of the diabetic foot: diagnostic challenges. Radiol Clin North Am 2005;43:747–59. ix.PubMedCrossRef
4.
go back to reference Gnanasegaran G, Chicklore S, Vijayanathan S, O’Doherty MJ, Fogelman I. Diabetes and bone: advantages and limitations of radiological, radionuclide and hybrid techniques in the assessment of diabetic foot. Minerva Endocrinol 2009;34:237–54.PubMed Gnanasegaran G, Chicklore S, Vijayanathan S, O’Doherty MJ, Fogelman I. Diabetes and bone: advantages and limitations of radiological, radionuclide and hybrid techniques in the assessment of diabetic foot. Minerva Endocrinol 2009;34:237–54.PubMed
5.
go back to reference Rozzanigo U, Tagliani A, Vittorini E, Pacchioni R, Brivio LR, Caudana R. Role of magnetic resonance imaging in the evaluation of diabetic foot with suspected osteomyelitis. Radiol Med 2009;114:121–32.PubMedCrossRef Rozzanigo U, Tagliani A, Vittorini E, Pacchioni R, Brivio LR, Caudana R. Role of magnetic resonance imaging in the evaluation of diabetic foot with suspected osteomyelitis. Radiol Med 2009;114:121–32.PubMedCrossRef
6.
go back to reference Rojas-Burke J. Health officials reacting to infection mishaps. J Nucl Med 1992;33:13N–4N. 27N. Rojas-Burke J. Health officials reacting to infection mishaps. J Nucl Med 1992;33:13N–4N. 27N.
7.
go back to reference de Vries EF, Roca M, Jamar F, Israel O, Signore A. Guidelines for the labelling of leucocytes with (99m)Tc-HMPAO. Inflammation/infection Taskgroup of the European Association of Nuclear Medicine. Eur J Nucl Med Mol Imaging 2010;37:842–8.PubMedCrossRef de Vries EF, Roca M, Jamar F, Israel O, Signore A. Guidelines for the labelling of leucocytes with (99m)Tc-HMPAO. Inflammation/infection Taskgroup of the European Association of Nuclear Medicine. Eur J Nucl Med Mol Imaging 2010;37:842–8.PubMedCrossRef
8.
go back to reference Schwenke C, Busse R. Analysis of differences in proportions from clustered data with multiple measurements in diagnostic studies. Methods Inf Med 2007;46:548–52.PubMed Schwenke C, Busse R. Analysis of differences in proportions from clustered data with multiple measurements in diagnostic studies. Methods Inf Med 2007;46:548–52.PubMed
9.
go back to reference Termaat MF, Raijmakers PG, Scholten HJ, Bakker FC, Patka P, Haarman HJ. The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis: a systematic review and meta-analysis. J Bone Joint Surg Am 2005;87:2464–71.PubMedCrossRef Termaat MF, Raijmakers PG, Scholten HJ, Bakker FC, Patka P, Haarman HJ. The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis: a systematic review and meta-analysis. J Bone Joint Surg Am 2005;87:2464–71.PubMedCrossRef
10.
go back to reference Steinsträsser A, Berberich R, Kuhlmann L, Zabori S, Schwarz A. Binding of the monoclonal antibody BW 250/183 to human granulocytes. Nuklearmedizin 1992;31:57–63.PubMed Steinsträsser A, Berberich R, Kuhlmann L, Zabori S, Schwarz A. Binding of the monoclonal antibody BW 250/183 to human granulocytes. Nuklearmedizin 1992;31:57–63.PubMed
11.
go back to reference Bosslet K, Steinsträsser A, Schwarz A, Harthus HP, Lüben G, Kuhlmann L, et al. Quantitative considerations supporting the irrelevance of circulating serum CEA for the immunoscintigraphic visualization of CEA expressing carcinomas. Eur J Nucl Med 1988;14:523–8.PubMedCrossRef Bosslet K, Steinsträsser A, Schwarz A, Harthus HP, Lüben G, Kuhlmann L, et al. Quantitative considerations supporting the irrelevance of circulating serum CEA for the immunoscintigraphic visualization of CEA expressing carcinomas. Eur J Nucl Med 1988;14:523–8.PubMedCrossRef
12.
go back to reference Morguet AJ, Munz DL, Ivancević V, Werner GS, Sandrock D, Bökemeier M, et al. Immunoscintigraphy using technetium-99m-labeled anti-NCA-95 antigranulocyte antibodies as an adjunct to echocardiography in subacute infective endocarditis. J Am Coll Cardiol 1994;23:1171–8.PubMedCrossRef Morguet AJ, Munz DL, Ivancević V, Werner GS, Sandrock D, Bökemeier M, et al. Immunoscintigraphy using technetium-99m-labeled anti-NCA-95 antigranulocyte antibodies as an adjunct to echocardiography in subacute infective endocarditis. J Am Coll Cardiol 1994;23:1171–8.PubMedCrossRef
13.
go back to reference Morguet AJ, Munz DL, Ivancević V, Werner GS, Kreuzer H. The clinical importance of scintigraphy with the murine monoclonal antigranulocyte antibody BW 250/183 for the diagnosis of prosthesis-related endocarditis. Dtsch Med Wochenschr 1995;120:861–6.PubMedCrossRef Morguet AJ, Munz DL, Ivancević V, Werner GS, Kreuzer H. The clinical importance of scintigraphy with the murine monoclonal antigranulocyte antibody BW 250/183 for the diagnosis of prosthesis-related endocarditis. Dtsch Med Wochenschr 1995;120:861–6.PubMedCrossRef
14.
go back to reference Segarra I, Roca M, Baliellas C, Vilar L, Ricart Y, Mora J, et al. Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease. Eur J Nucl Med 1991;18:715–9.PubMedCrossRef Segarra I, Roca M, Baliellas C, Vilar L, Ricart Y, Mora J, et al. Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease. Eur J Nucl Med 1991;18:715–9.PubMedCrossRef
15.
go back to reference Papos M, Nagy F, Narai G, Rajtar M, Szantai G, Lang J, et al. Anti-granulocyte immunoscintigraphy and [99mTc]hexamethylpropyleneamine-oxime-labeled leukocyte scintigraphy in inflammatory bowel disease. Dig Dis Sci 1996;41:412–20.PubMedCrossRef Papos M, Nagy F, Narai G, Rajtar M, Szantai G, Lang J, et al. Anti-granulocyte immunoscintigraphy and [99mTc]hexamethylpropyleneamine-oxime-labeled leukocyte scintigraphy in inflammatory bowel disease. Dig Dis Sci 1996;41:412–20.PubMedCrossRef
16.
go back to reference Almers S, Granerus G, Franzén L, Ström M. Technetium-99m scintigraphy: more accurate assessment of ulcerative colitis with exametazime-labelled leucocytes than with antigranulocyte antibodies. Eur J Nucl Med 1996;23:247–55.PubMedCrossRef Almers S, Granerus G, Franzén L, Ström M. Technetium-99m scintigraphy: more accurate assessment of ulcerative colitis with exametazime-labelled leucocytes than with antigranulocyte antibodies. Eur J Nucl Med 1996;23:247–55.PubMedCrossRef
17.
go back to reference Tarján Z, Tóth G, Györke T, Mester A, Karlinger K, Makó EK. Ultrasound in Crohn’s disease of the small bowel. Eur J Radiol 2000;35:176–82.PubMedCrossRef Tarján Z, Tóth G, Györke T, Mester A, Karlinger K, Makó EK. Ultrasound in Crohn’s disease of the small bowel. Eur J Radiol 2000;35:176–82.PubMedCrossRef
18.
go back to reference Peltier P, Potel G, Lovat E, Baron D, Chatal JF. Detection of lung and bone infection with anti-granulocyte monoclonal antibody BW 250/183 radiolabelled with 99Tcm. Nucl Med Commun 1993;14:766–74.PubMedCrossRef Peltier P, Potel G, Lovat E, Baron D, Chatal JF. Detection of lung and bone infection with anti-granulocyte monoclonal antibody BW 250/183 radiolabelled with 99Tcm. Nucl Med Commun 1993;14:766–74.PubMedCrossRef
19.
go back to reference Kroiss A, Sporn P, Auinger C, Redl E, Böck F, Dinstl K, et al. Immunoscintigraphy for detection of inflammatory perioperative foci. Acta Med Austriaca 1993;20:45–9.PubMed Kroiss A, Sporn P, Auinger C, Redl E, Böck F, Dinstl K, et al. Immunoscintigraphy for detection of inflammatory perioperative foci. Acta Med Austriaca 1993;20:45–9.PubMed
20.
go back to reference Becker W, Dölkemeyer U, Gramatzki M, Schneider MU, Scheele J, Wolf F. Use of immunoscintigraphy in the diagnosis of fever of unknown origin. Eur J Nucl Med 1993;20:1078–83.PubMedCrossRef Becker W, Dölkemeyer U, Gramatzki M, Schneider MU, Scheele J, Wolf F. Use of immunoscintigraphy in the diagnosis of fever of unknown origin. Eur J Nucl Med 1993;20:1078–83.PubMedCrossRef
21.
go back to reference Meller J, Ivancevic V, Conrad M, Gratz S, Munz DL, Becker W. Clinical value of immunoscintigraphy in patients with fever of unknown origin. J Nucl Med 1998;39:1248–53.PubMed Meller J, Ivancevic V, Conrad M, Gratz S, Munz DL, Becker W. Clinical value of immunoscintigraphy in patients with fever of unknown origin. J Nucl Med 1998;39:1248–53.PubMed
22.
go back to reference Gratz S, Behr TM, Herrmann A, Meller J, Conrad M, Zappel H, et al. Immunoscintigraphy (BW 250/183) in neonates and infants with fever of unknown origin. Nucl Med Commun 1998;19:1037–45.PubMedCrossRef Gratz S, Behr TM, Herrmann A, Meller J, Conrad M, Zappel H, et al. Immunoscintigraphy (BW 250/183) in neonates and infants with fever of unknown origin. Nucl Med Commun 1998;19:1037–45.PubMedCrossRef
23.
go back to reference Graute V, Feist M, Lehner S, Haug A, Müller PE, Bartenstein P, et al. Detection of low-grade prosthetic joint infections using (99m)Tc-antigranulocyte SPECT/CT: initial clinical results. Eur J Nucl Med Mol Imaging 2010;37:1751–9.PubMedCrossRef Graute V, Feist M, Lehner S, Haug A, Müller PE, Bartenstein P, et al. Detection of low-grade prosthetic joint infections using (99m)Tc-antigranulocyte SPECT/CT: initial clinical results. Eur J Nucl Med Mol Imaging 2010;37:1751–9.PubMedCrossRef
24.
go back to reference Guhlmann A, Brecht-Krauss D, Suger G, Glatting G, Kotzerke J, Kinzl L, et al. Fluorine-18-FDG PET and technetium-99m antigranulocyte antibody scintigraphy in chronic osteomyelitis. J Nucl Med 1998;39:2145–52.PubMed Guhlmann A, Brecht-Krauss D, Suger G, Glatting G, Kotzerke J, Kinzl L, et al. Fluorine-18-FDG PET and technetium-99m antigranulocyte antibody scintigraphy in chronic osteomyelitis. J Nucl Med 1998;39:2145–52.PubMed
25.
go back to reference Kaim A, Maurer T, Ochsner P, Jundt G, Kirsch E, Mueller-Brand J. Chronic complicated osteomyelitis of the appendicular skeleton: diagnosis with technetium-99m labelled monoclonal antigranulocyte antibody-immunoscintigraphy. Eur J Nucl Med 1997;24:732–8.PubMed Kaim A, Maurer T, Ochsner P, Jundt G, Kirsch E, Mueller-Brand J. Chronic complicated osteomyelitis of the appendicular skeleton: diagnosis with technetium-99m labelled monoclonal antigranulocyte antibody-immunoscintigraphy. Eur J Nucl Med 1997;24:732–8.PubMed
26.
go back to reference Kroiss A, Böck F, Perneczky G, Auinger C, Weidlich G, Kleinpeter G, et al. Immunoscintigraphy for the detection of inflammation foci in bone and joint diseases. Wien Klin Wochenschr 1990;102:713–7.PubMed Kroiss A, Böck F, Perneczky G, Auinger C, Weidlich G, Kleinpeter G, et al. Immunoscintigraphy for the detection of inflammation foci in bone and joint diseases. Wien Klin Wochenschr 1990;102:713–7.PubMed
27.
go back to reference Hotze AL, Briele B, Overbeck B, Kropp J, Gruenwald F, Mekkawy MA, et al. Technetium-99m-labeled anti-granulocyte antibodies in suspected bone infections. J Nucl Med 1992;33:526–31.PubMed Hotze AL, Briele B, Overbeck B, Kropp J, Gruenwald F, Mekkawy MA, et al. Technetium-99m-labeled anti-granulocyte antibodies in suspected bone infections. J Nucl Med 1992;33:526–31.PubMed
28.
go back to reference Reuland P, Winker KH, Heuchert T, Ruck P, Müller-Schauenburg W, Weller S, et al. Detection of infection in postoperative orthopedic patients with technetium-99m-labeled monoclonal antibodies against granulocytes. J Nucl Med 1991;32:2209–14.PubMed Reuland P, Winker KH, Heuchert T, Ruck P, Müller-Schauenburg W, Weller S, et al. Detection of infection in postoperative orthopedic patients with technetium-99m-labeled monoclonal antibodies against granulocytes. J Nucl Med 1991;32:2209–14.PubMed
29.
go back to reference Steinsträsser A, Oberhausen E. Granulocyte labelling kit BW 250/183–results of the European multicenter trial. Nuklearmedizin 1996;35:1–11.PubMed Steinsträsser A, Oberhausen E. Granulocyte labelling kit BW 250/183–results of the European multicenter trial. Nuklearmedizin 1996;35:1–11.PubMed
30.
go back to reference Boubaker A, Delaloye AB, Blanc CH, Dutoit M, Leyvraz PF, Delaloye B. Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses. Eur J Nucl Med 1995;22:139–47.PubMedCrossRef Boubaker A, Delaloye AB, Blanc CH, Dutoit M, Leyvraz PF, Delaloye B. Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses. Eur J Nucl Med 1995;22:139–47.PubMedCrossRef
31.
go back to reference Becker W, Bair J, Behr T, Repp R, Streckenbach H, Beck H, et al. Detection of soft-tissue infections and osteomyelitis using a technetium-99m-labeled anti-granulocyte monoclonal antibody fragment. J Nucl Med 1994;35:1436–43.PubMed Becker W, Bair J, Behr T, Repp R, Streckenbach H, Beck H, et al. Detection of soft-tissue infections and osteomyelitis using a technetium-99m-labeled anti-granulocyte monoclonal antibody fragment. J Nucl Med 1994;35:1436–43.PubMed
Metadata
Title
99mTc-besilesomab (Scintimun®) in peripheral osteomyelitis: comparison with 99mTc-labelled white blood cells
Authors
Wolf S. Richter
Velimir Ivancevic
Johannes Meller
Otto Lang
Dominique Le Guludec
István Szilvazi
Holger Amthauer
Florence Chossat
Amel Dahmane
Carsten Schwenke
Alberto Signore
Publication date
01-05-2011
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 5/2011
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-011-1731-2

Other articles of this Issue 5/2011

European Journal of Nuclear Medicine and Molecular Imaging 5/2011 Go to the issue