Background

Periprosthetic knee infection is troublesome for Orthopedic surgeons and a catastrophy for patients. Reported rates of periprosthetic joint infection following primary total knee arthroplasty (TKA) are 0.39–2%. Two stage revision arthroplasty, which has success rates exceeding 90%, has been the gold standard for treating subacute and chronic periprosthetic infection following TKA. Antibiotic spacers, a well established means of delivering local antibiotic therapy, maintain soft tissue tension during two stage revision arthroplasty. However, controversy remains around whether static or mobile antibiotic impregnated spacers are superior for treating infection following TKA. Various mobile spacers are available, including cement-on-cement, cement-on-polyethylene and metal-on-polyethylene. In this study, the efficacy of the modified metal-on-cement spacer, consisting of reinsertion of the autoclaved femoral component and implantation of antibiotic-loaded cement in the proximal tibia, is assessed.

Materials and Methods

Records of 19 patients diagnosed as periprosthetic knee infection were reviewed in this retrospective study. Among these patients, 10 patients received first stage debridement with the autoclaved metal-on-cement spacer and 8 patients with the static spacer, who eventually underwent two-stage re-implantation, were listed in the final comparison. Patient demographics, infection eradication rates, average range of motion (ROM), surgical time and blood loss during the second-stage of the surgery, and Knee Society (KS) knee scores at last followup after revision total knee replacement were clinically evaluated.

Results

At a minimum of 2-year followup after re-implantation, infection eradication rates, surgical times, blood loss during the second-stage of the surgery, and KS knee score after re-implantation were similar for the two groups. Patients receiving autoclaved metal-on-cement spacers had superior ROM after re-implantation compared to that of patients with static spacers.

Conclusions

The autoclaved metal-on-cement spacer is an effective and simple method for two-stage re-implantation of a periprosthetic knee infection. Through this spacer, the good interim ROM can be achieved without the additional cost of prefabricated molds or new polyethylene tibial inserts. In addition, ROM after re-implantation is better than that with static spacers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Kuzyk PR, Dhotar HS, Sternheim A, Gross AE, Safir O, Backstein D. Two-stage revision arthroplasty for management of chronic periprosthetic hip and knee infection: Techniques, controversies, and outcomes. J Am Acad Orthop Surg 2014;22:153–64.

    Article  Google Scholar 

  2. Peersman G, Laskin R, Davis J, Peterson M. Infection in total knee replacement: A retrospective review of 6489 total knee replacements. Clin Orthop Relat Res 2001;392:15–23.

    Article  Google Scholar 

  3. Teeny SM, Dorr L, Murata G, Conaty P. Treatment of infected total knee arthroplasty. Irrigation and debridement versus two-stage reimplantation. J Arthroplasty 1990;5:35–9.

    Article  CAS  Google Scholar 

  4. Haleem AA, Berry DJ, Hanssen AD. Mid-term to long term followup of two-stage reimplantation for infected total knee arthroplasty. Clin Orthop Relat Res 2004;428:35–9.

    Article  Google Scholar 

  5. Jacobs C, Christensen CP, Berend ME. Static and mobile antibiotic-impregnated cement spacers for the management of prosthetic joint infection. J Am Acad Orthop Surg 2009;17:356–68.

    Article  Google Scholar 

  6. Park SJ, Song EK, Seon JK, Yoon TR, Park GH. Comparison of static and mobile antibiotic-impregnated cement spacers for the treatment of infected total knee arthroplasty. Int Orthop 2010;34:1181–6.

    Article  Google Scholar 

  7. Emerson RH Jr, Muncie M, Tarbox TR, Higgins LL. Comparison of a static with a mobile spacer in total knee infection. Clin Orthop Relat Res 2002;404:132–8.

    Article  Google Scholar 

  8. Haddad FS, Masri BA, Campbell D, McGraw RW, Beauchamp CP, Duncan CP. The PROSTALAC functional spacer in two-stage revision for infected knee replacements. Prosthesis of antibiotic-loaded acrylic cement. J Bone Joint Surg Br 2000;82:807–12.

    Article  CAS  Google Scholar 

  9. Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 1989;248:13–4.

    Google Scholar 

  10. Kim TW, Makani A, Choudhury R, Kamath AF, Lee GC. Patient-reported activity levels after successful treatment of infected total knee arthroplasty. J Arthroplasty 2012;27:81–5.

    Article  Google Scholar 

  11. Silvestre A, Almeida F, Renovell P, Morante E, López R. Revision of infected total knee arthroplasty: Two-stage reimplantation using an antibiotic-impregnated static spacer. Clin Orthop Surg 2013;5:180–7.

    Article  Google Scholar 

  12. Voleti PB, Baldwin KD, Lee GC. Use of static or articulating spacers for infection following total knee arthroplasty: A systematic literature review. J Bone Joint Surg Am 2013;95:1594–9.

    Article  Google Scholar 

  13. Munro JT, Garbuz DS, Masri BA, Duncan CP. Articulating antibiotic impregnated spacers in two-stage revision of infected total knee arthroplasty. J Bone Joint Surg Br 2012;94:123–5.

    Article  CAS  Google Scholar 

  14. Ha CW. A technique for intraoperative construction of antibiotic spacers. Clin Orthop Relat Res 2006;445:204–9.

    PubMed  Google Scholar 

  15. Fehring TK, Odum S, Calton TF, Mason JB. Articulating versus static spacers in revision total knee arthroplasty for sepsis. The Ranawat Award. Clin Orthop Relat Res 2000;380:9–16.

    Article  Google Scholar 

  16. Hsu YC, Cheng HC, Ng TP, Chiu KY. Antibiotic-loaded cement articulating spacer for 2-stage reimplantation in infected total knee arthroplasty: A simple and economic method. J Arthroplasty 2007;22:1060–6.

    Article  CAS  Google Scholar 

  17. Jämsen E, Sheng P, Halonen P, Lehto MU, Moilanen T, Pajamäki J, et al. Spacer prostheses in two-stage revision of infected knee arthroplasty. Int Orthop 2006;30:257–61.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wei-Pin Ho.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, YP., Wu, CC. & Ho, WP. Autoclaved metal-on-cement spacer versus static spacer in two-stage revision in periprosthetic knee infection. IJOO 50, 146–153 (2016). https://doi.org/10.4103/0019-5413.177587

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.4103/0019-5413.177587

Key words

MeSH terms

Navigation