Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used.

Materials and Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system.

Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient.

Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ring D, Perey BH, Jupiter JB. The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients. J Bone Joint Surg Am 1999;81:177–90.

    Article  CAS  Google Scholar 

  2. Jupiter JB, Wyss H. Stable fixation of osteoporotic fractures and nonunions in the upper limb-life before the “locking plate”. Acta Chir Orthop Traumatol Cech 2010;77:361–4.

    PubMed  CAS  Google Scholar 

  3. Ring D, Kloen P, Kadzielski J, Helfet D, Jupiter JB. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res 2004;425:50–4.

    Article  Google Scholar 

  4. Nadkarni B, Srivastav S, Mittal V, Agarwal S. Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: Review of literature and our experience. J Trauma 2008;65:482–6.

    Article  Google Scholar 

  5. Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 1987;214:160–4.

    Google Scholar 

  6. Rubel IF, Kloen P, Campbell D, Schwartz M, Liew A, Myers E, et al. Open reduction and internal fixation of humeral nonunionsA biomechanical and clinical study. J Bone Joint Surg Am 2002;84-A:1315–22.

    Article  Google Scholar 

  7. Lin CL, Fang CK, Chiu FY, Chen CM, Chen TH. Revision with dynamic compression plate and cancellous bone graft for aseptic nonunion after surgical treatment of humeral shaft fracture. J Trauma 2009;67:1393–6.

    Article  Google Scholar 

  8. Hornicek FJ, Zych GA, Hutson JJ, Malinin TI. Salvage of humeral nonunions with onlay bone plate allograft augmentation. Clin Orthop Relat Res 2001;386:203–9.

    Article  Google Scholar 

  9. Hsu TL, Chiu FY, Chen CM, Chen TH. Treatment of nonunion of humeral shaft fracture with dynamic compression plate and cancellous bone graft. J Chin Med Assoc 2005;68:73–6.

    Article  Google Scholar 

  10. Van Houwelingen AP, McKee MD. Treatment of osteopenic humeral shaft nonunion with compression plating, humeral cortical allograft struts, and bone grafting. J Orthop Trauma 2005;19:36–42.

    Article  Google Scholar 

  11. Vidyadhara S, Vamsi K, Rao SK, Gnanadoss JJ, Pandian S. Use of intramedullary fibular strut graft: A novel adjunct to plating in the treatment of osteoporotic humeral shaft nonunion. Int Orthop 2009;33:1009–14.

    Article  CAS  Google Scholar 

  12. Trader JE, Johnson RP, Kalbfleisch JH. Bone-mineral content, surface hardness, and mechanical fixation in the human radius. A correlative study. J Bone Joint Surg Am 1979;61:1217–20.

    Article  CAS  Google Scholar 

  13. de Boer HH, Wood MB, Hermans J. Reconstruction of large skeletal defects by vascularized fibula transfer. Factors that influenced the outcome of union in 62 cases. Int Orthop 1990;14:121–8.

    Article  Google Scholar 

  14. McKee MD, Miranda MA, Reimer BL, Blasier RB, Redmond BJ, Sims SH, et al. Management of humeral nonunions after failure of intramedullary nails. J Orthop Trauma 1996;10:492–9.

    Article  CAS  Google Scholar 

  15. Farragos AF, Schemitsch EH, McKee MD. Complications of intramedullary nailing for fractures of the humeral shaft: A review. J Orthop Trauma 1999;13:258–67.

    Article  CAS  Google Scholar 

  16. Ajmal M, O’Sullivan M, McCabe J, Curtin W. Antegrade locked intramedullary nailing in humeral shaft fractures. Injury 2001;32:692–4.

    Article  CAS  Google Scholar 

  17. Kurup H, Hossain M, Andrew JG. Dynamic compression plating versus locked intramedullary nailing for humeral shaft fractures in adults. Cochrane Database Syst Rev 2011;15:CD005959.

  18. Putti AB, Uppin RB, Putti BB. Locked intramedullary nailing versus dynamic compression plating for humeral shaft fractures. J Orthop Surg (Hong Kong) 2009;17:139–41.

    Article  Google Scholar 

  19. Denies E, Nijs S, Sermon A, Broos P. Operative treatment of humeral shaft fractures. Comparison of plating and intramedullary nailing. Acta Orthop Belg 2010;76:735–42.

    PubMed  Google Scholar 

  20. Modabber MR, Jupiter JB. Operative management of diaphyseal fractures of the humerus. Plate versus nail. Clin Orthop Relat Res 1998;347:93–104.

    Article  Google Scholar 

  21. Niall DM, O’Mahony J, McElwain JP. Plating of humeral shaft fractures–Has the pendulum swung back? Injury 2004;35:580–6.

    Article  CAS  Google Scholar 

  22. McCormack RG, Brien D, Buckley RE, McKee MD, Powell J, Schemitsch EH. Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial. J Bone Joint Surg Br 2000;82:336–9.

    Article  CAS  Google Scholar 

  23. Lammens J, Bauduin G, Driesen R, Moens P, Stuyck J, De Smet L, et al. Treatment of nonunion of the humerus using the Ilizarov external fixator. Clin Orthop Relat Res 1998;353:223–30.

    Article  Google Scholar 

  24. Kiran M, Jee R. Ilizarov’s method for treatment of nonunion of diaphyseal fractures of the humerus. Indian J Orthop 2010;44:444–7.

    Article  Google Scholar 

  25. Maini L, Chadha M, Vishwanath J, Kapoor S, Mehtani A, Dhaon BK. The Ilizarov method in infected nonunion of fractures. Injury 2000;31:509–17.

    Article  CAS  Google Scholar 

  26. Raschke M, Khodadayan C, Maitini PD, Hoffmann R, Südkamp NP. Nonunion of humerus following intramedullary nailing treated by Ilizarov’s external fixator. J Orthop Trauma 1998;12:138–41.

    Article  CAS  Google Scholar 

  27. Singh HP. Humeral nonunion after failure of plate fixation, managed by Ilizarov fixator. Indian J Orthop 2004;38:107–9.

    Google Scholar 

  28. Patel VR, Menon DK, Pool RD, Simonis RB. Nonunion of the humerus after failure of surgical treatment. Management using the Ilizarov circular fixator. J Bone Joint Surg Br 2000;82:977–83.

    Article  CAS  Google Scholar 

  29. Gardner MJ, Griffith MH, Demetrakopoulos D, Brophy RH, Grose A, Helfet DL, et al. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg Am 2006;88:1962–7.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Malhar N. Kumar.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kumar, M.N., Ravindranath, V.P. & Ravishankar, M.R. Outcome of locking compression plates in humeral shaft nonunions. IJOO 47, 150–155 (2013). https://doi.org/10.4103/0019-5413.108899

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.4103/0019-5413.108899

Key words

Navigation