Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter August 15, 2019

Establishment of the intelligent verification criteria for a routine urinalysis analyzer in a multi-center study

  • Li Wang , Ye Guo , Jiang Han , Jing Jin , Cuiling Zheng , Junxia Yang , Jia Xu , Jiaxing Wang , Xiaowei Wang , Yingying Hao , Wei Wu EMAIL logo , Guijian Liu EMAIL logo and Wei Cui EMAIL logo

Abstract

Background

Although laboratory information system (LIS) is widely used nowadays, the results of routine urinalysis still need 100% manual verification. We established intelligent verification criteria to perform the automated verification process and reduce manual labor.

Methods

A total of 4610 urine specimens were obtained from the patients of three hospitals in Beijing, China. Firstly, 895 specimens were measured to establish the reference intervals of formed-element parameters in UF5000. Secondly, 2803 specimens were analyzed for setting up the intelligent verification criteria (including the microscopic review rules and manual verification rules). Lastly, 912 specimens were used to verify the efficacy and accuracy of the intelligent verification criteria. Phase-contrast microscopes were used for the microscopic review.

Results

Employing a results level corresponding relationship in specific parameters including hemoglobin (red blood cell [RBC]), leukocyte esterase (white blood cell [WBC]) and protein (cast) between the dry-chemistry analysis and formed-element analysis, as well as instrument flags, we established seven WBC verification rules, eight RBC verification rules and four cast verification rules. Based on the microscopy results, through analyzing the pre-set rules mentioned earlier, we finally determined seven microscopic review rules, nine manual verification rules and three auto-verification rules. The microscopic review rate was 21.98% (616/2803), the false-negative rate was 4.32% (121/2803), the total manual verification rate was 35.71% (1001/2803) and the auto-verification rate was 64.29% (1802/2803). The validation results were consistent.

Conclusions

The intelligent verification criteria for urinary dry-chemistry and urinary formed-element analysis can improve the efficiency of the results verification process and ensure the reliability of the test results.

Award Identifier / Grant number: 2017-I2M-3-005

Funding statement: This work was supported by the CAMS Innovation Fund for Medical Sciences (CIFMS) (grant no. 2017-I2M-3-005).

  1. Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

  2. Research funding: None declared.

  3. Employment or leadership: None declared.

  4. Honorarium: None declared.

  5. Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.

References

1. Wen DM, Zhang XM, Wang WJ, Zhang DC, Fan YL, Hu T, et al. Establishment and application of the autoverification system in laboratory clinical chemistry and immunology laboratory. Chinese J Lab Med 2018;41:141–8.Search in Google Scholar

2. Li XB, Pu ZF, Tao CL, Gao H. Establishment and application of autoverification procedure for clinical chemistry test results. Chinese J Lab Med 2018;41:547–53.Search in Google Scholar

3. Palmieri R, Falbo R, Cappellini F, Soldi C, Limonta G, Brambilla P. The development of autoverification rules applied to urinalysis performed on the AutionMAX-SediMAX platform. Clin Chim Acta 2018;485:275–81.10.1016/j.cca.2018.07.001Search in Google Scholar PubMed

4. Clinical and Laboratory Standards Institute. Autoverification of Clinical Laboratory Test Results, Approved Guideline. CLSI AUTO10-A, 2010.Search in Google Scholar

5. China National Accreditation Service for Conformity Assessment (CNAS). Accreditation Criteria for the Quality and Competence of Medical Laboratories, Third ed. CNAS-CL02, 2012.Search in Google Scholar

6. Shang H, Wang YS, Shen ZY. National guide to clinical laboratory procedures, 4th ed. Beijing: People’s Medical Publishing House, 2015:160–74.Search in Google Scholar

7. Clinical and Laboratory Standards Institute. Urinalysis, Approved Guideline, 3rd ed. CLSI GPl6-A3, 2009.Search in Google Scholar

8. Clinical and Laboratory Standards Institute. Defining, Establishing, and Verifying Reference Intervals in the Clinical Laboratory, Approved Guideline, Third ed. CLSI C28-A3, 2010.Search in Google Scholar

9. Kouri T, Gyory A, Rowan RM, Force IUT. ISLH recommended reference procedure for the enumeration of particles in urine. Lab Hematol 2003;9:58–63.Search in Google Scholar

10. Sakai S, Shirakawa C, Hisashi K. General inspection technique guide book. Tokyo, Japan: Maruzen Publishing, 2017:69.Search in Google Scholar

11. Liu Y, Dan G, Jiang ZY, Xiong J. Exploring the value of the combining the RBC laser parameters and UF-1000i in diagnosing of glomerular hematuria. Sichuan Med J 2015;36:1153–6.Search in Google Scholar

12. Oyaert MN, Himpe J, Speeckaert MM, Stove VV, Delanghe JR. Quantitative urine test strip reading for leukocyte esterase and hemoglobin peroxidase. Clin Chem Lab Med 2018;56:1126–32.10.1515/cclm-2017-1159Search in Google Scholar PubMed

13. Chen Y, Cheng M, Li W, Du J, Li JY, Wu W, et al. Development and clinical application of microscopy review criteria of automated urine chemistry and sedimental analysis. Chinese J Lab Med 2011;34:501–6.Search in Google Scholar

14. China National Accreditation Service for Conformity Assessment (CNAS). Guidance on the Application of Accreditation Criteria for the Medical Laboratory Quality and Competence in the Field of Body Fluid Examination, Third Ed. CNAS-CL41, 2012.Search in Google Scholar

15. Barnes PW, McFadden SL, Machin SJ, Simson E, International Consensus Group for Hematology. The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis. Lab Hematol 2005;11:83–90.10.1532/LH96.05019Search in Google Scholar PubMed

16. Ma JL, Cong YL, Lu YJ, Wang CB, Liu PP, Zhang YQ, et al. Study and application of the combination of urine dry chemistry examination and urine sediment flow cytometry examination on the microscopic screening of the urine formed component. Chinese J Lab Med 2011;34:494–500.Search in Google Scholar

17. Du J, Xu J, Wang F, Guo Y, Zhang F, Wu W, et al. Establishment and development of the personalized criteria for microscopic review following multiple automated routine urinalysis systems. Clin Chim Acta 2015;444:221–8.10.1016/j.cca.2015.02.022Search in Google Scholar PubMed

18. Delanghe JR, Himpe J, De Cock N, Delanghe S, De Herde K, Stove V, et al. Sensitive albuminuria analysis using dye-binding based test strips. Clin Chim Acta 2017;471:107–12.10.1016/j.cca.2017.05.032Search in Google Scholar PubMed

19. Salinas M, Lopez-Garrigos M, Flores E, Lugo J, Leiva-Salinas C, Group PRC-Lw. Urinary albumin strip assay as a screening test to replace quantitative technology in certain conditions. Clin Chem Lab Med 2018;57:204–9.10.1515/cclm-2018-0546Search in Google Scholar PubMed

20. Previtali G, Ravasio R, Seghezzi M, Buoro S, Alessio MG. Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber. Clin Chim Acta 2017;472:123–30.10.1016/j.cca.2017.07.028Search in Google Scholar PubMed

21. Laboratory Physicians Branch of Chinese Medical Doctor Association. Expert consensus on the format of the diagnosis report for routine urinalysis. Nat Med J China 2017;97:1369–72.Search in Google Scholar

22. Gong DY, Xu WC, Zheng JS. Clinical basic laboratory, 1st ed. Beijing: People’s Medical Publishing House, 2017:225–7.Search in Google Scholar

23. Yu JH, Rong LX, Yu XJ, Du XX, Zhang MN. Effects of different storage conditions of urine specimens on routine urinalysis related indexes. Lab Med Clinic 2018;15:1309–11.Search in Google Scholar

24. Hou L, Chen JL, Liu R, Long XQ. Effect of different storage duration of urine specimens on urinary sediment related indexes. J Clin Res 2017;34:635–6, 640.Search in Google Scholar

Received: 2019-03-29
Accepted: 2019-06-26
Published Online: 2019-08-15
Published in Print: 2019-11-26

©2019 Walter de Gruyter GmbH, Berlin/Boston

Downloaded on 29.5.2024 from https://www.degruyter.com/document/doi/10.1515/cclm-2019-0344/html
Scroll to top button