Skip to main content
Log in

Double Application of TA-90 B Four-Row AutoSuture® Stapling Instrument: A Safe, Effective Method of Staple-Line Production Indicated by Follow-up GI Series

  • Published:
Obesity Surgery Aims and scope Submit manuscript

Background: Controversy continues concerning the best method of isolating upper and lower gastric pouches in Roux-Y gastric bypass. This paper reports a technique used from August 1991 through May 1996, in which there was a double application of the TA-90 B Four-Row AutoSuture® Stapling Instrument to form the proximal gastric pouch. Because of a significant staple-line failure rate historically, many are separating the pouches. However, due to recent reports of gastro-gastric fistula formation when pouch separation is done, a second look has been taken at stapling the division without separation of the pouches. Methods: There were 650 patients in this series, and 160 asymptomatic patients 1-4 years postoperatively agreed to have limited upper GI series. Results: Only one of this group had staple-line failure. Failures were seen in four of 19 symptomatic patients with dyspepsia or rapid weight regain. Putting these two groups together, our staple-line failure rate has been less than 1% using this technique. Conclusion: Whether stapling in continuity or dividing the stomach, the two methods appear to be equally effective with comparable morbidity. Patients with staple-line failure or gastro-gastric fistulae will ultimately be forced by their symptoms of rapid weight regain and/or peptic ulcer disease and reflux esophagitis to return for follow-up. Asymptomatic patients very rarely have a connection between upper and lower pouches, and routine follow-up upper GI series are not indicated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jones, K.B., Homza, W., Peavy, P.W. et al. Double Application of TA-90 B Four-Row AutoSuture® Stapling Instrument: A Safe, Effective Method of Staple-Line Production Indicated by Follow-up GI Series. OBES SURG 6, 494–499 (1996). https://doi.org/10.1381/096089296765556395

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1381/096089296765556395

Navigation