Paper
1 February 1995 Bending of the manubrium in cat under normal sound stimulation
Willem F. Decraemer, Shyam M. Khanna, W. Robert J. Funnell
Author Affiliations +
Proceedings Volume 2329, Optical and Imaging Techniques in Biomedicine; (1995) https://doi.org/10.1117/12.200867
Event: International Symposium on Biomedical Optics Europe '94, 1994, Lille, France
Abstract
It is generally considered that in coupling the motion of the tympanic membrane to the incus, the malleus behaves as a rigid body. To investigate the bending of the manubrium, its vibrations were measured with an interferometer in response to sound applied to the ear at a large number of observation points along its center line. Measurements at an arbitrary position are now possible due to high interferometer sensitivity. The x, y, and z coordinates of the observation points were measured with optical scales incorporated in the positioning system. The displacements are plotted as a function of position along the manubrium at seven phases (30 degree(s) apart throughout a half cycle). At low frequencies the bending is moderate and near the tip. In portions in the mid and high frequencies the bending is quite strong and extends to the middle region of the manubrium or is absent and the extreme lower edge of the malleus tip does not seem to vibrate solidly with the rest of the manubrium.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Willem F. Decraemer, Shyam M. Khanna, and W. Robert J. Funnell "Bending of the manubrium in cat under normal sound stimulation", Proc. SPIE 2329, Optical and Imaging Techniques in Biomedicine, (1 February 1995); https://doi.org/10.1117/12.200867
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ear

Solids

Interferometers

Microscopes

Motion models

Astatine

Bone

Back to Top