Abstract
Background/Objectives:
Multi-frequency bioelectrical impedance analysis (MFBIA) is increasingly being used to assess peritoneal dialysis patients. Protein energy wasting (PEW) is a recognised complication of peritoneal dialysis. Although MFBIA can be used to assess body composition, measurements can be affected by fluid overload, and we wished to determine whether the presence of peritoneal dialysate in the peritoneal cavity equally could affect MFBIA-derived body composition assessments.
Subjects/Methods:
Fifty consecutive adult patients had MFBIA made with 2l 22.7g/l dextrose dialysate instilled into the peritoneal cavity and then after draining out.
Results:
When full, extracellular water (ECW) and the ratio of ECW to total body water (TBW) were greater compared with when empty: 13.9±3.0l versus 13.4±3.0, and 0.393±0.01 versus 0.391±0.01, P<0.001, respectively. Segmental ECW/TBW was only different for the trunk, 0.395±0.01 full versus 0.392±0.01 empty, P<0.0001. Body composition changed with a fall in skeletal muscle mass from 26.1±6.3 to 25.2±6.1kg, P<0.001, and a smaller reduction in body fat from 19.3±8.4 to 19.1±8.0kg, P=0.0104.
Conclusion:
MFBIA measurements made in peritoneal dialysis patients with peritoneal dialysate instilled can overestimate body composition, including muscle mass, and as such potentially delay the recognition of PEW. Thus, for more accurate MFBIA in peritoneal dialysis patients, the dialysate should be drained out.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Wang AY . Energy intake and energy expenditure profiles in peritoneal dialysis patients. Ren Nutr 2011; 21: 31–34.
Davenport A . Peritonitis remains the major clinical complication of peritoneal dialysis: the London, UK, peritonitis audit 2002-2003. Perit Dial Int 2009; 29: 297–302.
Fan S, Sayed RH, Davenport A . Extracellular volume expansion in peritoneal dialysis patients. Int J Artif Organs 2012; 35: 338–345.
Han SH, Han DS . Nutrition in patients on peritoneal dialysis. Nat Rev Nephrol 2012; 8: 163–175.
Fürstenberg A, Davenport A . Comparison of multifrequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry assessments in outpatient haemodialysis patients. Am J Kidney Dis 2011; 57: 123–129.
Parmentier SP, Schirutschke H, Schmitt B, Schewe J, Herbrig K, Pistrosch F et al. Influence of peritoneal dialysis solution on measurements of fluid status by bioimpedance spectroscopy. Int Urol Nephrol. e-pub ahead of print 19 June 2012; PMID: 22710970.
Bedogni G, Malavolti M, Severi S, Poli M, Mussi C, Fantuzzi AL et al. Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water. Eur J Clin Nutr 2002; 56: 1143–1148.
Fürstenberg A, Davenport A . Assessment of body composition in peritoneal dialysis patients using bioelectrical impedance and dual-energy X-Ray absorptiometry. Am J Nephrol 2011; 33: 150–156.
Booth J, Pinney J, Davenport A . The effect of vascular access modality on changes in fluid content in the arms as determined by multifrequency bioimpedance. Nephrol Dial Transplant 2011; 26: 227–231.
Than N, Woodrow G, Oldroyd B, Gonzalez C, Turney JH, Brownjohn AM . Effect of peritoneal fluid on whole body and segmental multiple frequency bioelectrical impedance in patients on peritoneal dialysis. Eur J Clin Nutr 2000; 54: 450–451.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The author declares no conflict of interest.
Rights and permissions
About this article
Cite this article
Davenport, A. Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients?. Eur J Clin Nutr 67, 223–225 (2013). https://doi.org/10.1038/ejcn.2012.205
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/ejcn.2012.205
Keywords
This article is cited by
-
Effect of peritoneal dialysate on bioelectrical impedance analysis variability in pediatric patients receiving peritoneal dialysis
Pediatric Nephrology (2024)
-
Segmental bioimpedance in pregnant end stage renal failure patient for dry weight titration and volume management (case report)
BMC Nephrology (2023)
-
Estimated dietary sodium intake in peritoneal dialysis patients using food frequency questionnaires and total urinary and peritoneal sodium losses and assessment of extracellular volumes
European Journal of Clinical Nutrition (2019)
-
Clinical value of body composition monitor to evaluate lean and fat tissue mass in peritoneal dialysis
European Journal of Clinical Nutrition (2019)
-
The prevalence of muscle wasting (sarcopenia) in peritoneal dialysis patients varies with ethnicity due to differences in muscle mass measured by bioimpedance
European Journal of Clinical Nutrition (2018)