Skip to main content

Advertisement

Log in

Evaluating the effect of low-level laser therapy on pain induced by orthodontic separation: a randomized split-mouth clinical trial

  • Original Article
  • Published:
Lasers in Dental Science Aims and scope Submit manuscript

Abstract

Introduction

Pain is the most common sequela reported by patients undergoing orthodontic treatment. It is a prime concern as despite the desire, the orthodontic treatment is refuted by most patients because of the associated pain and discomfort. Recently, there is an abundance of research going on in the field of orthodontics regarding the causes of orthodontic pain and the measures that could efficiently reduce it. One such method is the administration of lasers to reduce the intensity of pain. Therefore, the aim of this study was to assess the effect of low-level laser therapy on spontaneous pain and pain on chewing caused by elastomeric separators.

Method

Forty patients were randomly selected for this single-blind, split-mouth study. Elastomeric separators were placed mesial and distal to the permanent first molars in all the four quadrants. The arches were divided into experimental and control sides. The experimental side was treated with low-level laser therapy on two points on the buccal and lingual mucosa for 20 s each, with a 940-nm gallium-aluminum-arsenic diode laser on continuous mode and power set at 200 mW. The other side received placebo laser therapy without turning on the laser. A visual analogue scale was used to assess the intensity of spontaneous pain and pain on chewing, and the subjects were asked to mark the pain scores in a questionnaire given to them at different time intervals. The independent samples t test and analysis of variance with the post hoc Tukey test was used to analyze the results.

Results

The subjects reported less intensity of pain on chewing as well as spontaneous pain at the sites which were given low-level laser therapy as compared to the placebo side. The difference between the pain intensity on the low-level laser therapy side and placebo side was found to be statistically significant (p ≤ 0.05).

Conclusion

A single dose of low-level laser therapy is an effective modality in significantly reducing the intensity of both spontaneous and pain on chewing caused after the placement of elastomeric separators.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Turhani D, Scheriau M, Kapral D, Benesch T, Jonke E, Bantleon HP (2006) Pain relief by single low-level laser irradiation in orthodontic patients undergoing fixed appliance therapy. Am J Orthod Dentofac Orthop 130:371–377

    Article  Google Scholar 

  2. Deshpande P, Patil K, Mahima VG, Shivalinga BM, Suchetha M, Ranjan A (2016) Low-level laser therapy for alleviation of pain from fixed orthodontic appliance therapy: a randomized controlled trial. J Adv Clin Res Insights 3:43–46

    Article  Google Scholar 

  3. Abtahi SM, Mousavi SA, Shafaee H, Tanbakuchi B (2013) Effect of low-level laser therapy on dental pain induced by separator force in orthodontic treatment. Dent Res J 10:647–651

    Google Scholar 

  4. Shi Q, Yang S, Jia F, Xu J (2015) Does low level laser therapy relieve the pain caused by the placement of the orthodontic separators? A meta-analysis. Head Face Med 11(1):28

    Article  PubMed  PubMed Central  Google Scholar 

  5. Bergius M, Kiliaridis S, Berggren U (2000) Pain in orthodontics. A review and discussion of the literature. J Orofac Orthop 61(2):125–137

    Article  PubMed  Google Scholar 

  6. Qamruddin I, Alam MK, Fida M, Khan AG (2016) Effect of a single dose of low-level laser therapy on spontaneous and chewing pain caused by elastomeric separators. Am J Orthod Dentofac Orthop 149(1):62–66

    Article  Google Scholar 

  7. Scheurer PA, Firestone AR, Burgin WB (1996) Perception of pain as a result of orthodontic treatment with fixed appliances. Eur J Orthod 18:349–357

    Article  PubMed  Google Scholar 

  8. Ngan P, Kess B, Wilson S (1989) Perception of discomfort by patients undergoing orthodontic treatment. Am J Orthod Dentofac Orthop 96:47–53

    Article  Google Scholar 

  9. Mester E, Szende B (1967) Influence of laser on hair growth of mice. Kiserl Orvostud 19:628–631

    Google Scholar 

  10. Oltra-Arimon D, Spain-Tost AJ, Berini-Aytés L, Gay-Escoda C (2004) Low-power laser applications in dentistry. RCOE 9(5):517–524

    Article  Google Scholar 

  11. Eslamian L, Borzabadi-Farahani A, Hassanzadeh-Azhiri A, Badiee MR, Fekrazad R. The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers Med Sci 2014;29:559–564. 22

    Article  PubMed  Google Scholar 

  12. Marini I, Bartolucci ML, Bortolotti F, Innocenti G, Gatto MR, Bonetti GA (2015) The effect of diode superpulsed low-level laser therapy on experimental orthodontic pain caused by elastomeric separators: a randomized controlled clinical trial. Lasers Med Sci 30:35–41

    Article  PubMed  Google Scholar 

  13. Farias RD, Closs LQ, Miguens SAQ Jr (2016) Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: a randomized split-mouth clinical trial. Angle Orthod 86(2):193–198

    Article  PubMed  Google Scholar 

  14. Lim HM, Lew KK, Tay DK (1995) A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic post adjustment pain. Am J Orthod Dentofac Orthop 108:614–622

    Article  Google Scholar 

  15. Zawawi KH (2014) Acceptance of orthodontic miniscrews as temporary anchorage devices. Patient Prefer Adherence 30(8):933–937

    Article  Google Scholar 

  16. Farivar S, Malekshahabi T, Shiari R (2014) Biological effects of low level laser therapy. J Lasers Med Sci 5(2):58–62

    PubMed  PubMed Central  Google Scholar 

  17. Doshi-Mehta G, Bhad-Patil WA (2012 Mar 31) Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation. Am J Orthod Dentofac Orthop 141(3):289–297

    Article  Google Scholar 

  18. Rosas S, Paço M, Lemos C, Pinho T (2017) Comparison between the Visual Analog Scale and the Numerical Rating Scale in the perception of esthetics and pain. Int Orthod 15(4):543–560

    PubMed  Google Scholar 

  19. Chow R, Armati P, Laakso EL, Bjordal JM, Baxter GD (2011) Inhibitory effects of laser irradiation on peripheral mammalian nerves and relevance to analgesic effects: a systematic review. Photomed Laser Surg 29(6):356–381

    Article  Google Scholar 

  20. Laakso EL, Cabot PJ (2005) Nociceptive scores and endorphin-containing cells reduced by low-level laser therapy (LLLT) in inflamed paws of Wistar rat. Photomed Laser Surg 23(1):32–35

    Article  PubMed  Google Scholar 

  21. Asiry MA, Albarakati SF, Al-Marwan MS, Al-Shammari RR (2014) Perception of pain and discomfort from elastomeric separators in Saudi adolescents. Saudi Med J 35:504–507

    PubMed  Google Scholar 

  22. Kapoor P, Singh H, Ghai GS, Ghai GK (2013) Perception of pain and discomfort from three types of orthodontic separators. Indian J Dent Sci 5:9–13

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Surbhi Sharma.

Ethics declarations

The study was approved by the institutional ethical committee.

Conflict of interest

No potential conflict of interest was reported by the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gupta, S., Ahuja, S., Bhambri, E. et al. Evaluating the effect of low-level laser therapy on pain induced by orthodontic separation: a randomized split-mouth clinical trial. Laser Dent Sci 2, 221–228 (2018). https://doi.org/10.1007/s41547-018-0040-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s41547-018-0040-5

Keywords

Navigation