Skip to main content

Advertisement

Log in

Influence of storage on the quality of conventional CT and µCT-imaging for the middle and inner cat ear

  • Original Article
  • Published:
Anatomical Science International Aims and scope Submit manuscript

Abstract

The aim of this study was to analyze whether different fixation methods such as freezing or formaldehyde storage for different periods of time have an influence on the recognition of anatomical relevant structures in the middle and inner ear of the cat with conventional computed tomography (cCT) and micro-computed tomography (µCT). Besides, effects of freeze–thaw cycles on determined structures of the ear were investigated by means of histological slices. Three veterinarians with different radiologic expertise evaluated the scans of 30 dissected cat ears anonymously and scored predefined structures in a five-point scale with reference to visually sharp reproducibility and perfect image quality. The total scores of the different fixation groups as well as the ears within a group were compared with each other. Furthermore, an intra-reader examination including an evaluation of the identifiability of specified structures was performed for both imaging methods. cCT as well as µCT-scans have a very low variation coefficient of 1.6% and 2.3%, respectively. The results for the alterations between the different fixation methods show that the changes for cCT-scans are negligible, as the percentage alteration compared to fresh samples ranges in a very small interval with values from 1.0% better to 1.2% worse. µCT-scans are more influenced by the fixation method with a range from 1.3% better to 6.9% worse values. The scans mostly deteriorated after two freeze–thaw cycles (1.8% worse) and after storing the samples for 1 (2.4% worse), respectively, and 3 weeks in formaldehyde (6.9% worse).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  • Beck T, Kilchling TP, Meyer-Lindenberg A (2019) Differences between µCT-imaging and conventional CT for the diagnosis of possible diseases of the middle and inner cat ear. Anat Histol Embryol 48:268–276

    Article  Google Scholar 

  • Bolliger SA, Tomasin D, Heimer J, Richter H, Thali MJ, Gascho D (2018) Rapid and reliable detection of previous freezing of cerebral tissue by computed tomography and magnetic resonance imaging. Forensic Sci Med Pathol 14:85–94

    Article  Google Scholar 

  • Bongartz G, Golding S, Jurik A, Leonardi van Meerten E, Geleijns J, Jessen K, Panzer W, Shrimpton P, Tosi G (1998) European guidelines on quality criteria for computed tomography. EUR 16262 EN, 1–23

  • Bullen A, Taylor RR, Kachar B, Moores C, Fleck RA, Forge A (2014) Inner ear tissue preservation by rapid freezing: improving fixation by high-pressure freezing and hybrid methods. Hear Res 315:49–60

    Article  CAS  Google Scholar 

  • Cisneros JC, Brito R, Martins GS, Candido N, Ferraz R, Bento R (2017) Evaluation of the microgrinding procedure for the microscopic analysis of temporal bones. Cochlear Implants Int 18:106–115

    Article  CAS  Google Scholar 

  • Decraemer WF, Dirckx JJ, Funnell WR (2003) Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner. J Assoc Res Otolaryngol 4:250–263

    Article  CAS  Google Scholar 

  • Fallon JB, Shepherd RK, Nayagam DA, Wise AK, Heffer LF, Landry TG, Irvine DR (2014) Effects of deafness and cochlear implant use on temporal response characteristics in cat primary auditory cortex. Hear Res 315:1–9

    Article  Google Scholar 

  • George SS, Wise AK, Shivdasani MN, Shepherd RK, Fallon JB (2014) Evaluation of focused multipolar stimulation for cochlear implants in acutely deafened cats. J Neural Eng 11:065003

    Article  Google Scholar 

  • Hammer N, Voigt C, Werner M, Hoffmann F, Bente K, Kunze H, Scholz R, Steinke H (2014) Ethanol and formaldehyde fixation irreversibly alter bones’ organic matrix. J Mech Behav Biomed Mater 29:252–258

    Article  CAS  Google Scholar 

  • Hassepass F, Bulla S, Maier W, Laszig R, Arndt S, Beck R, Traser L, Aschendorff A (2014) The new mid-scala electrode array: a radiologic and histologic study in human temporal bones. Otol Neurotol 35:1415–1420

    Article  Google Scholar 

  • Kim JS, Lee JS, Park M-H, Kang H, Lee JJ, Lee H-J, Im KC, Moon DH, Lim S-M, Oh S-H (2008) Assessment of cerebral glucose metabolism in cat deafness model: strategies for improving the voxel-based statistical analysis for animal PET studies. Mol Imaging Biol 10:154–161

    Article  Google Scholar 

  • Klop AC, Vester MEM, Colman KL, Ruijter JM, Van Rijn RR, Oostra RJ (2017) The effect of repeated freeze-thaw cycles on human muscle tissue visualized by postmortem computed tomography (PMCT). Clin Anat 30:799–804

    Article  Google Scholar 

  • Lander SL, Brits D, Hosie M (2014) The effects of freezing, boiling and degreasing on the microstructure of bone. Homo 65:131–142

    Article  CAS  Google Scholar 

  • Lane JI, Witte RJ, Driscoll CL, Camp JJ, Robb RA (2004) Imaging microscopy of the middle and inner ear: Part I: CT microscopy. Clin Anat 17:607–612

    Article  Google Scholar 

  • Lee W, Jasiuk I (2014) Effects of freeze–thaw and micro-computed tomography irradiation on structure-property relations of porcine trabecular bone. J Biomech 47:1495–1498

    Article  Google Scholar 

  • Levy AD, Harcke HT, Mallak CT (2010) Postmortem imaging: MDCT features of postmortem change and decomposition. Am J Forensic Med Pathol 31:12–17

    Article  Google Scholar 

  • Maran A, Khosla S, Riggs BL, Zhang M, Ritman EL, Turner RT (2003) Measurement of gene expression following cryogenic mu-CT scanning of human iliac crest biopsies. J Musculoskelet Neuronal Interact 3:83–88

    CAS  PubMed  Google Scholar 

  • McElderry JD, Kole MR, Morris MD (2011) Repeated freeze-thawing of bone tissue affects Raman bone quality measurements. J Biomed Opt 16:071407

    Article  Google Scholar 

  • Middlebrooks JC, Snyder RL (2007) Auditory prosthesis with a penetrating nerve array. J Assoc Res Otolaryngol 8:258–279

    Article  Google Scholar 

  • Morita K, Doi K, Oue H, Kajihara S, Hayashi K, Akagawa Y (2013) Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone. Br J Oral Maxillofac Surg 51:550–554

    Article  Google Scholar 

  • Peake WT, Rosowski JJ, Lynch TJ (1992) Middle-ear transmission: acoustic versus ossicular coupling in cat and human. Hear Res 57:245–268

    Article  CAS  Google Scholar 

  • Poznyakovskiy AA, Zahnert T, Kalaidzidis Y, Schmidt R, Fischer B, Baumgart J, Yarin YM (2008) The creation of geometric three-dimensional models of the inner ear based on micro computer tomography data. Hear Res 243:95–104

    Article  Google Scholar 

  • Schuknecht H (1993) Pathology of the inner ear, 2nd edn. Lea & Febiger, Philadelphia

    Google Scholar 

  • Scruggs JL, Flatland B, Reed A (2014) Effects of freezing on tissue factor activity in a thromboelastography assay. Vet Clin Pathol 43:322–325

    Article  Google Scholar 

  • Seidel A, Bergauer B, Lell M, Buder T, von Wilmowsky C, Dach E, Wichmann M, Matta RE (2018) Does formalin fixation influence MSCT/CBCT accuracy? Surg Radiol Anat 40:31–37

    Article  Google Scholar 

  • Smith ZM, Delgutte B (2007) Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants. J Assoc Res Otolaryngol 8:134–151

    Article  Google Scholar 

  • Tirko NN, Ryugo DK (2012) Synaptic plasticity in the medial superior olive of hearing, deaf, and cochlear-implanted cats. J Comp Neurol 520:2202–2217

    Article  Google Scholar 

  • Uzun H, Curthoys IS, Jones AS (2007) A new approach to visualizing the membranous structures of the inner ear—high resolution X-ray micro-tomography. Acta Otolaryngol 127:568–573

    Article  Google Scholar 

  • van der Made AD, Maas M, Beenen LF, Oostra RJ, Kerkhoffs GM (2013) Postmortem imaging exposed: an aid in MR imaging of musculoskeletal structures. Skelet Radiol 42:467–472

    Article  Google Scholar 

  • Wehrl HF, Bezrukov I, Wiehr S, Lehnhoff M, Fuchs K, Mannheim JG, Quintanilla-Martinez L, Kohlhofer U, Kneilling M, Pichler BJ, Sauter AW (2015) Assessment of murine brain tissue shrinkage caused by different histological fixatives using magnetic resonance and computed tomography imaging. Histol Histopathol 30:601–613

    CAS  PubMed  Google Scholar 

  • Wei Z, Niu Q, Zhang F, Xiao K, Liu L, Wang Y, Jia J, Cao J, Fu S, Yun K (2017) The effect of sodium fluoride, formaldehyde, and storage temperature on the stability of methamidophos in post-mortem blood and liver. Int J Legal Med 131:667–675

    Article  Google Scholar 

Download references

Acknowledgements

Thanks go to the team in the laboratory in the area of research of the veterinary faculty of the Ludwig-Maximilians-University of Munich who supported and guided the author on how to operate with the µCT and the machines to prepare the histological slices.

Author information

Authors and Affiliations

Authors

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Beck, T., Kilchling, T., Reese, S. et al. Influence of storage on the quality of conventional CT and µCT-imaging for the middle and inner cat ear. Anat Sci Int 95, 190–201 (2020). https://doi.org/10.1007/s12565-019-00509-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12565-019-00509-y

Keywords

Navigation