Abstract
The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clinical crossover designed study is to evaluate the feasibility of the HMD for ultrasound-guided nerve block. Eight experienced anesthesiologists performed ultrasound-guided peripheral nerve blocks on a training simulator with a standard approach and with an upside-down approach. Each approach was performed with a control conventional method and with an HMD. The ultrasound image and operating field were recorded by video camera. The procedure time and fractional percentage of time with the needle visible on the ultrasound image were determined. The needle insertion times were 10.4 ± 7.2 s with the control method and 6.8 ± 5.3 s with the HMD method for the standard approach (p = 0.03), and 18.1 ± 10.1 with the control method and 11.8 ± 9.5 s with the HMD method for the upside-down approach (p = 0.002). The fractional percentages of time with the needle visible on the ultrasound image were 34.1 ± 20.9 with the control method and 56.5 ± 13.6% with the HMD method for the standard approach (p < 0.001), and 20.1 ± 13.4 with the control method and 38.2 ± 21.2% with the HMD method for the upside-down approach (p = 0.001). In conclusion, this pilot study using a simulation model indicated that the use of an HMD shortened the procedure time and improved the needle visibility on ultrasound.
References
Struck MF, Kaisers UX. Iatrogenic jugular-carotid fistula despite ultrasound-guided vascular access. Eur J Anaesthesiol. 2015;32:63–4.
MacLennan N, Nixon C. Pneumothorax following ultrasound-guided interscalene block: association or complication? Eur J Anaesthesiol. 2014;31:244.
Omar AM, Wade NJ, Brown SI, Cuschieri A. Assessing the benefits of “gaze-down” display location in complex tasks. Surg Endosc. 2005;19:105–8.
Ames C, Frisella AJ, Yan Y, Shulam P, Landman J. Evaluation of laparoscopic performance with alteration in angle of vision. J Endourol. 2006;20:281–3.
Takeshita H, Kihara K, Yoshida S, Higuchi S, Ito M, Nakanishi Y, Kijima T, Ishioka J, Matsuoka Y, Numao N, Saito K, Fujii Y. Clinical application of a modern high-definition head-mounted display in sonography. J Ultrasound Med. 2014;33:1499–504.
Liu D, Jenkins SA, Sanderson PM, Watson MO, Leane T, Kruys A, Russell WJ. Monitoring with head-mounted displays: performance and safety in a full-scale simulator and part-task trainer. Anesth Analg. 2009;109:1135–46.
Liu D, Jenkins SA, Sanderson PM, Fabian P, Russell WJ. Monitoring with head-mounted displays in general anesthesia: a clinical evaluation in the operating room. Anesth Analg. 2010;110:1032–8.
Udani AD, Harrison TK, Howard SK, Kim TE, Brock-Utne JG, Gaba DM, Mariano ER. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display. J Ultrasound Med. 2012;31:1277–80.
Sites BD, Spence BC, Gallagher JD, Wiley CW, Bertrand ML, Blike GT. Characterizing novice behavior associated with learning ultrasound-guided peripheral regional anesthesia. Reg Anesth Pain Med. 2007;32:107–15.
Schwenk ES, Gandhi K, Baratta JL, Torjman M, Epstein RH, Chung J, Vaghari BA, Beausang D, Bojaxhi E, Grady B. Ultrasound-guided out-of-plane vs. in-plane interscalene catheters: a randomized, prospective study. Anesth Pain Med. 2015;5:e31111.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Kasuya, Y., Moriwaki, S., Inano, C. et al. Feasibility of the head-mounted display for ultrasound-guided nerve blocks: a pilot simulator study. J Anesth 31, 782–784 (2017). https://doi.org/10.1007/s00540-017-2371-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00540-017-2371-x