Skip to main content
Log in

Feasibility of the head-mounted display for ultrasound-guided nerve blocks: a pilot simulator study

  • Short Communication
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clinical crossover designed study is to evaluate the feasibility of the HMD for ultrasound-guided nerve block. Eight experienced anesthesiologists performed ultrasound-guided peripheral nerve blocks on a training simulator with a standard approach and with an upside-down approach. Each approach was performed with a control conventional method and with an HMD. The ultrasound image and operating field were recorded by video camera. The procedure time and fractional percentage of time with the needle visible on the ultrasound image were determined. The needle insertion times were 10.4 ± 7.2 s with the control method and 6.8 ± 5.3 s with the HMD method for the standard approach (p = 0.03), and 18.1 ± 10.1 with the control method and 11.8 ± 9.5 s with the HMD method for the upside-down approach (p = 0.002). The fractional percentages of time with the needle visible on the ultrasound image were 34.1 ± 20.9 with the control method and 56.5 ± 13.6% with the HMD method for the standard approach (p < 0.001), and 20.1 ± 13.4 with the control method and 38.2 ± 21.2% with the HMD method for the upside-down approach (p = 0.001). In conclusion, this pilot study using a simulation model indicated that the use of an HMD shortened the procedure time and improved the needle visibility on ultrasound.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. Struck MF, Kaisers UX. Iatrogenic jugular-carotid fistula despite ultrasound-guided vascular access. Eur J Anaesthesiol. 2015;32:63–4.

    Article  PubMed  Google Scholar 

  2. MacLennan N, Nixon C. Pneumothorax following ultrasound-guided interscalene block: association or complication? Eur J Anaesthesiol. 2014;31:244.

    Article  PubMed  Google Scholar 

  3. Omar AM, Wade NJ, Brown SI, Cuschieri A. Assessing the benefits of “gaze-down” display location in complex tasks. Surg Endosc. 2005;19:105–8.

    Article  CAS  PubMed  Google Scholar 

  4. Ames C, Frisella AJ, Yan Y, Shulam P, Landman J. Evaluation of laparoscopic performance with alteration in angle of vision. J Endourol. 2006;20:281–3.

    Article  PubMed  Google Scholar 

  5. Takeshita H, Kihara K, Yoshida S, Higuchi S, Ito M, Nakanishi Y, Kijima T, Ishioka J, Matsuoka Y, Numao N, Saito K, Fujii Y. Clinical application of a modern high-definition head-mounted display in sonography. J Ultrasound Med. 2014;33:1499–504.

    Article  PubMed  Google Scholar 

  6. Liu D, Jenkins SA, Sanderson PM, Watson MO, Leane T, Kruys A, Russell WJ. Monitoring with head-mounted displays: performance and safety in a full-scale simulator and part-task trainer. Anesth Analg. 2009;109:1135–46.

    Article  PubMed  Google Scholar 

  7. Liu D, Jenkins SA, Sanderson PM, Fabian P, Russell WJ. Monitoring with head-mounted displays in general anesthesia: a clinical evaluation in the operating room. Anesth Analg. 2010;110:1032–8.

    Article  PubMed  Google Scholar 

  8. Udani AD, Harrison TK, Howard SK, Kim TE, Brock-Utne JG, Gaba DM, Mariano ER. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display. J Ultrasound Med. 2012;31:1277–80.

    Article  PubMed  Google Scholar 

  9. Sites BD, Spence BC, Gallagher JD, Wiley CW, Bertrand ML, Blike GT. Characterizing novice behavior associated with learning ultrasound-guided peripheral regional anesthesia. Reg Anesth Pain Med. 2007;32:107–15.

    Article  PubMed  Google Scholar 

  10. Schwenk ES, Gandhi K, Baratta JL, Torjman M, Epstein RH, Chung J, Vaghari BA, Beausang D, Bojaxhi E, Grady B. Ultrasound-guided out-of-plane vs. in-plane interscalene catheters: a randomized, prospective study. Anesth Pain Med. 2015;5:e31111.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yusuke Kasuya.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kasuya, Y., Moriwaki, S., Inano, C. et al. Feasibility of the head-mounted display for ultrasound-guided nerve blocks: a pilot simulator study. J Anesth 31, 782–784 (2017). https://doi.org/10.1007/s00540-017-2371-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-017-2371-x

Keywords

Navigation