Abstract
The temporary cavity of a missile produces radial tears in ordnance gelatine, which correlate to the energy transfer. Computed tomography is a useful and non-destructive method to examine gelatine blocks. However, the tears give only few radiocontrast by air filling, which decreases with the time past shooting. Therefore, systematically, a radiocontrast material was searched to enhance the contrast. Different contrast materials were amalgamated to acryl paint, and about 7 g was sealed in a foil bag, which was integrated in the front of a standard 10% gelatine cylinder. Shots with Action-5 expanding bullets were performed from a 5-m distance. Gelatine was scanned by multi-slice computed tomography. The multiplanar reconstructed images were compared to mechanically cut slices of 1 cm thickness. It was shown experimentally that iodine containing water-soluble contrast material did not give sufficient contrast and caused diffusion artefacts. Best results were obtained by barium sulphate emulsion. The amount of acryl paint was sufficient to colour the tears for optical scanning. The radiocontrast of barium leads to satisfying imaging of tears and allowed the creation of a three-dimensional reconstruction of the temporary cavity. Comparison of optical and radiological results showed an excellent correlation, but absolute measures in computed tomographic (CT) images remained lower compared with optically gathered values in the gelatine slices. Combination of paint and contrast material for CT examination will facilitate the evaluation of complex ballistic models and increase accuracy.
Similar content being viewed by others
References
Fackler ML, Malinowski JA (1985) The wound profile: a visual method for quantifying gunshot wound components. J Trauma 25:522–529
Fackler ML (1987) What’s wrong with the wound ballistics literature, and why. Letterman Army Institute of Research, Report No 239, July 1987
Korac Z, Kelenc D, Baskot A, Mikulic D, Hancevic J (2001) Substitute ellipse of the permanent cavity in gelatine blocks and debridement of gunshot wounds. Mil Med 166:689–694
Fackler ML, Surinchak JS, Malinowski JA, Bowen RE (1984) Wounding potential of the Russian AK-74 assault rifle. J Trauma 24(3):263–266
Fackler ML, Malinowski JA (1988) Ordnance gelatin for ballistic studies. Detrimental effect of excess heat used in gelatin preparation. Am J Forensic Med Pathol 9:218–219
Jeffery AJ, Rutty GN, Robinson C, Morgan B (2008) Computed tomography of projectile injuries. Clin Radiol 63:1160–1166
Korac Z, Kelenc D, Hancevic J, Baskot A, Mikulic D (2002) The application of computed tomography in the analysis of permanent cavity: a new method in terminal ballistics. Acta Clin Croat 41:205–209
Bolliger SA, Thali MJ, Bolliger MJ, Kneubuehl BP (2010) Gunshot energy transfer profile in ballistic gelatine, determined with computed tomography using the total crack length method. Int J Leg Med 124:613–616, Epub 2010 Aug 20
Harcke HT, Levy AD, Getz JM, Robinson SR (2008) MDCT analysis of projectile injury in forensic investigation. Am J Roentgenol 190(2):W106–W111
Schyma C (2010) Colour contrast in ballistic gelatine. Forensic Sci Int 197:114–118
Schyma C, Madea B (2010) Schussspurensicherung-Praktischer Umgang mit Schuss-und Schmauchspuren. Rechtsmedizin 20:123–136
Stein KM, Grünberg K (2009) Forensische radiologie. Radiologe 49:73–85
Thali MJ, Yen K, Vock P, Ozdoba C, Kneubuehl BP, Sonnenschein M, Dirnhofer R (2003) Image-guided virtual autopsy findings of gunshot victims performed with multi-slice computed tomography and magnetic resonance imaging and subsequent correlation between radiology and autopsy findings. Forensic Sci Int 138:8–16
Stein KM, Bahner ML, Merkel J, Ain S, Mattern R (2000) Detection of gunshot residues in routine CTs. Int J Leg Med 114:15–18
Cecchetto G, Giraudo C, Amagliani A, Viel G, Fais P, Cavarzeran F, Feltrin G, Ferrara SD, Montisci M (2010) Estimation of the firing distance through micro-CT analysis of gunshot wounds. Int J Leg Med 125(2):245–251
Rutty GN, Boyce P, Robinson CE, Jeffery AJ, Morgan B (2008) The role of computed tomography in terminal ballistic analysis. Int J Leg Med 122(1):1–5
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Schyma, C., Hagemeier, L., Greschus, S. et al. Visualisation of the temporary cavity by computed tomography using contrast material. Int J Legal Med 126, 37–42 (2012). https://doi.org/10.1007/s00414-010-0546-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00414-010-0546-1