Abstract
Background:
Intramedullary nails have become a popular implant in the management of femoral shaft fractures. The occurrence of a femoral neck fracture after closed intramedullary nailing is an exceptional complication of this technique that has been rarely reported in the literature.
Methods:
We report a retrospective study to identify the possible causes that could produce a fracture of the femoral neck after nailing of the ipsilateral femur.
Results:
A total of four neck fractures were identified in a series of 494 femoral shaft nailing, all of them not visible on the initial plain films. In two cases, the nail entry point was located lateral to the tip of the greater trochanter. In the other two cases, the entry point was located too medial to the greater trochanter, violating the superoexternal cortex of the femoral neck.
Conclusion:
The event of a femoral neck fracture during closed intramedullary nailing is an unusual complication that may be caused due to a technical mistake related to the location of the nail entry portal in the proximal femur.
Similar content being viewed by others
References
Bick EM. The intramedullary nailing of fractures by G. Küntscher. Translation of article in Archiv für Klinische Chirurgie, 200:443, 1940. Clin Orthop Relat Res 1968;60:5–12.
Winquist RA, Hansen ST Jr, Clawson DK. Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J Bone Joint Surg Am 1984;66:529–539.
Brumback RJ, Uwagie-Ero S, Lakatos RP, Poka A, Bathon GH, Burgess AR. Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation. J Bone Joint Surg Am 1988;70:1453–1462.
Harper MC, Henstorf J. Fractures of the femoral neck associated with technical errors in closed intramedullary nailing of the femur. Report of two cases. J Bone Joint Surg Am 1986;68:624–626.
Christie J, Court-Brown C. Femoral neck fracture during closed medullary nailing: brief report. J Bone Joint Surg Br 1988;70:670.
Böstman O, Varjonen L, Vainionpää S, Majola A, Rokkanen P. Incidence of local complications after intramedullary nailing and after plate fixation of femoral shaft fractures. J Trauma 1989;29:639–645.
Simonian PT, Chapman JR, Selznick HS, Benirschke SK, Claudi BF, Swiontkowski MF. Iatrogenic fractures of the femoral neck during closed nailing of the femoral shaft. J Bone Joint Surg Br 1994;76:293–296.
Khan FA, Ikram MA, Badr AA, al-Khawashki H. Femoral neck fracture: a complication of femoral nailing. Injury 1995;26:319–321.
Yang KH, Han DY, Park HW, Kang HJ, Park JH. Fracture of the ipsilateral neck of the femur in shaft nailing. The role of CT in diagnosis. J Bone Joint Surg Br 1998;80:673–678.
Bonnevialle P, Glasson JM, Determe P, Bellumore Y, Mansat M. Iatrogenic cervical fracture after femoral diaphyseal nailing. Rev Chir Orthop Reparatrice Appar Mot 1999;85:397–403.
Wolinsky PR, Johnson KD. Ipsilateral femoral neck and shaft fractures. Clin Orthop Relat Res 1995;318:81–90.
Alho A. Concurrent ipsilateral fractures of the hip and femoral shaft: a meta-analysis of 659 cases. Acta Orthop Scand 1996;67:19–28.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Castellanos, J., Garcia-Nuño, L., Cavanilles-Walker, J.M. et al. Iatrogenic femoral neck fracture during closed nailing of the femoral shaft fracture. Eur J Trauma Emerg Surg 35, 479–481 (2009). https://doi.org/10.1007/s00068-009-8151-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00068-009-8151-z