Skip to main content
Log in

Reduced technetium 99m labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution

Technical note

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

The influence of reconstituting a murine monoclonal IgG1 antibody kit with pertechnetate technetium 99m on antibody distribution in the liver, spleen and sternal bone marrow of patients was examined. The99mTc-labelled antibody used is directed against nonspecific cross-reacting antigen (NCA-95) and carcinoembryonic antigen (CEA) and has been successfully applied for imaging tissue inflammation and bone marrow scanning. Radioactivity uptake was determined in the liver, spleen, bone marrow and a precordial background region in a consecutive series of 25 patients, examined with an antibody preparation, routinely radiolabelled according to the manufacturer's recommendations and in 14 patients, in whom the antibody was reconstituted with special care, avoiding bubble formation and dropping of buffer into the antibody-containing vial. Gentle compared with routine antibody reconstitution caused a highly significant reduction of the antibody uptake in the liver, as determined by count densities, normalized to injected dose and acquisition time (13.2 ± 5.5 vs 20.1 ± 6.0 cpm per pixel, x±SID,P=0.008). The liver to background ratio was reduced from 3.4 ± 1.4 to 1.9 ±0.5 (P < 0.001). Spleen, sternal bone marrow and precordial background count rates were not significantly affected. These results clearly demonstrate that gentle antibody reconstitution can decrease non-specific antibody uptake in the liver by 34% ± 6.4% (x ± SEM). Thus, scan quality is improved, and the potential deleterious camouflage of underlying structures is avoided.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Berberich R, Zabori S, Hennes P (1989) Erfahrungen mit dem monoklonalen Antikörper BW 259/183 zum Nachweis von entzündlichen Veränderungen. Nuklearmedizin 28:154 (abstr)

    Google Scholar 

  • Bosslet K, Lüben G, Schwarz A, Hundt E, Harthus HP, Seiler FR, Muhrer C, Kloeppel G, Kayser K, Sedlacek HH (1985) Immunohistochemical localisation and molecular characteristics of three monoclonal antibody defined epitopes detectable on carcinoembryonic antigen (CEA). Int J Cancer 36:75–84

    Google Scholar 

  • Burtin P, Quan PC, Sabine MC (1975) Nonspecific cross reacting antigen as a marker for human polymorphs, macrophages and monocytes. Nature 255:714–716

    Google Scholar 

  • Joseph K, Höffken K, Bosslet K, Schorlemmer HU (1988) In vivo labelling of granulocytes with99mTc anti-NCA monoclonal antibodies for imaging inflammation. Eur J Nucl Med 14:367–373

    Google Scholar 

  • Reske SN, Vyska K, Feinendegen LE (1981) In vivo assessment of phagocytic properties of Kupffer cells. J Nucl Med 22:405–410

    Google Scholar 

  • Reske SN, Karstens JH, Gloeckner W, Steinstraesser A, Schwarz A, Ammon J, Buell U (1989) Radioimmunoimaging for diagnosis of bone marrow involvement in breast cancer and malignant lymphoma. Lancet 1:299–301

    Google Scholar 

  • Schwarz A (1989)99mTc Markierung monoklonaler Antikörper -ihre technische Durchführung und klinische Bedeutung. Nuklearmedizin 28:151 (abstr)

    Google Scholar 

  • Schwarz A, Steinstraesser A (1987) A novel approach to Tc-99m labelled monoclonal antibodies. J Nucl Med 28:721 (abstr)

    Google Scholar 

  • Silverstein SC, Steinman RM, Cohn ZA (1977) Endocytosis. Ann Rev Biochem 46:669–722

    Google Scholar 

  • Srivastava SC, Meinken GM (1986) Correlating labeling chemistry and in vitro test results with the biological behaviour of radiolabeled proteins. Int J Biol Markers 3:111–120

    Google Scholar 

  • Steinstraesser A, Schorlemmer HU, Schwarz A, Kuhlmann L, Bosslet K (1988) A novel Tc-99m labelled antibody for in vivo targeting of granulocytes. J Nucl Med 29:925 (abstr)

    Google Scholar 

  • Toth CA, Thomas P,Broitman SA, Zamchek N (1985) Receptor-mediated endocytosis of carcinoembryonic antigen by rat liver Kupffer cells. Cancer Res 45:392–397

    Google Scholar 

  • Wahren B, Gahrton G, Hammerstroem S (1980) Non-specific cross-reacting antigen in normal and myeloid cells and serum of leukemic patients. Cancer Res 40:2039–2044

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reske, S.N., Buell, U. Reduced technetium 99m labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution. Eur J Nucl Med 17, 38–41 (1990). https://doi.org/10.1007/BF00819402

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00819402

Key words

Navigation