  • Chapter
  • First Online:
Basics of PET Imaging

Abstract

A major goal of the PET studies is to obtain a good quality and detailed image of an object by the PET scanner, and so it depends on how well the scanner performs in image formation. Several parameters associated with the scanner are critical to good quality image formation, which include spatial resolution, sensitivity, noise, scattered radiations, and contrast. These parameters are interdependent, and if one parameter is improved, one or more of the others are compromised. A description of these parameters is given below.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 79.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 99.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References and Suggested Reading

  • ACR (2007). CT Accreditation Program Requirements

    Google Scholar 

  • Brix G, Zaers J, Adam LE et al (1997). Performance evaluation of a whole-body PET scanner using the NEMA protocol. J Nucl Med 38:1614

    PubMed  CAS  Google Scholar 

  • Buchert R, Bohuslavizki UH, Mester J et al (1999). Quality assurance in PET: evaluation of the clinical relevance of detector defects. J Nucl Med 40:1657

    PubMed  CAS  Google Scholar 

  • Budinger TF (1998). PET instrumentation: what are the limits? Semin Nucl Med 28:247

    Article  PubMed  CAS  Google Scholar 

  • Cherry SR, Sorensen JA, Phelps ME (2003). Physics in Nuclear Medicine. 3rd ed. Saunders, Philadelphia

    Google Scholar 

  • Daube-Witherspoon ME, Karp JS, Casey ME et al (2002). PET performance measurement using the NEMA NU 2-2001 standard. J Nucl Med 43:1398

    PubMed  Google Scholar 

  • Huesman RH (1977). The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstruction. Phys Med Biol 22:511

    Article  PubMed  CAS  Google Scholar 

  • Karp JS, Daube-Witherspoon ME, Hoffman EJ et al (1991). Performance standards in positron emission tomography. J Nucl Med 32:2342

    PubMed  CAS  Google Scholar 

  • Kearfott K (1989). Sinograms and diagnostic tools for the quality assurance of a positron emission tomograph. J Nucl Med Technol 17:83

    Google Scholar 

  • Keim P (1994). An overview of PET quality assurance procedures: part 1. J Nucl Med Technol 22:27

    Google Scholar 

  • Moses WW, Derenzo SE (1993). Empirical observation of performance degradation in positron emission tomographs utilizing block detectors. J Nucl Med 34:101P

    Google Scholar 

  • National Electrical Manufacturers Association (1994). NEMA Standards Publications NU 2-1994. Performance measurements of positron emission tomographs, National Electrical Manufacturers Association, Washington DC

    Google Scholar 

  • National Electrical Manufacturers Association (2001). NEMA Standard Publication NU 2-2001. Performance measurements of positron emission tomographs, National Electrical Manufacturers Association, Rosslyn, VA

    Google Scholar 

  • National Electrical Manufacturers Association (2007). NEMA Standard Publication NU 2-2007. Performance measurements of positron emission tomographs, National Electrical Manufacturers Association, Rosslyn, VA

    Google Scholar 

  • Tarantola G, Zito F, Gerundini P (2003). PET instrumentation and reconstruction algorithms in whole-body applications. J Nucl Med 44:756

    PubMed  Google Scholar 

  • Watson CC, Casey ME, Eriksonn L et al (2004). NEMA NU2 performance tests for scanners with intrinsic activity. J Nucl Med 45:822

    PubMed  CAS  Google Scholar 

  • Zanzonico P (2008). Routine quality control of clinical nuclear medicine instrumentation: a brief review. J Nucl Med 49:1114

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Saha, G.B. (2010). Performance Characteristics of PET Scanners. In: Basics of PET Imaging. Springer, New York, NY. https://doi.org/10.1007/978-1-4419-0805-6_6

Download citation

  • DOI: https://doi.org/10.1007/978-1-4419-0805-6_6

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4419-0804-9

  • Online ISBN: 978-1-4419-0805-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics