Abstract
In this technique development study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was applied to non-invasively image and quantify 3D joint space morphology of the wrist and metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA). HR-pQCT imaging (82 μm voxel-size) of the dominant hand was performed in patients with diagnosed rheumatoid arthritis (RA, N = 16, age: 52.6 ± 12.8) and healthy controls (CTRL, N = 7, age: 50.1 ± 15.0). An automated computer algorithm was developed to segment wrist and MCP joint spaces. The 3D distance transformation method was applied to spatially map joint space width, and summarized by the mean joint space width (JSW), minimal and maximal JSW (JSW.MIN, JSW.MAX), asymmetry (JSW.AS), and distribution (JSW.SD)—a measure of joint space heterogeneity. In vivo precision was determined for each measure by calculating the smallest detectable difference (SDD) and root mean square coefficient of variation (RMSCV%) of repeat scans. Qualitatively, HR-pQCT images and pseudo-color JSW maps showed global joint space narrowing, as well as regional and focal abnormalities in RA patients. In patients with radiographic JSN at an MCP, JSW.SD was two-fold greater vs. CTRL (p < 0.01), and JSW.MIN was more than two-fold lower (p < 0.001). Similarly, JSW.SD was significantly greater in the wrist of RA patients vs. CTRL (p < 0.05). In vivo precision was highest for JSW (SDD: 100 μm, RMSCV: 2.1%) while the SDD for JSW.MIN and JSW.SD were 370 and 110 μm, respectively. This study suggests that in vivo quantification of 3D joint space morphology from HR-pQCT, could improve early detection of joint damage in rheumatological diseases.
Similar content being viewed by others
Abbreviations
- HR-pQCT:
-
High-resolution peripheral quantitative computed tomography
- RA:
-
Rheumatoid arthritis
- CTRL:
-
Control
- DMARD:
-
Disease-modifying antrirheumatic drug
- MCP:
-
Metacarpophalangeal
- RU:
-
Radioulnar
- RS:
-
Radioscaphoid
- RL:
-
Radiolunate
- VOI:
-
Volume of interest
- SDD:
-
Smallest detectable difference
- JSN:
-
Joint space narrowing
- JSV:
-
Joint space volume
- JSW:
-
Joint space width
- JSW.MIN:
-
JSW minimum
- JSW.MAX:
-
JSW maximum
- JSW.SD:
-
JSW standard deviation (heterogeneity)
- JSW.AS:
-
JSW asymmetry
References
Aletaha, D., J. Funovits, and J. S. Smolen. Physical disability in rheumatoid arthritis is associated with cartilage damage rather than bone destruction. Ann. Rheum. Dis. 70(5):733–739, 2011.
Barnabe, C., and L. Feehan. High-resolution peripheral quantitative computed tomography imaging protocol for metacarpophalangeal joints in inflammatory arthritis: the SPECTRA collaboration. J. Rheumatol. 39(7):1494–1495, 2012.
Bland, J. M., and D. G. Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310, 1986.
Boutroy, S., M. L. Bouxsein, F. Munoz, and P. D. Delmas. In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J. Clin. Endocrinol. Metab. 90(12):6508–6515, 2005.
Boutroy, S., B. Van Rietbergen, E. Sornay-Rendu, F. Munoz, M. L. Bouxsein, and P. D. Delmas. Finite element analysis based on in vivo HR-pQCT images of the distal radius is associated with wrist fracture in postmenopausal women. J. Bone Miner. Res. 23(3):392–399, 2008.
Buie, H. R., G. M. Campbell, R. J. Klinck, J. A. MacNeil, and S. K. Boyd. Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. Bone 41(4):505–515, 2007.
Burghardt, A. J., J. B. Pialat, G. J. Kazakia, S. Boutroy, K. Engelke, J. M. Patsch, A. Valentinitsch, D. Liu, E. Szabo, C. E. Bogado, M. B. Zanchetta, H. A. McKay, E. Shane, S. K. Boyd, M. L. Bouxsein, R. Chapurlat, S. Khosla, and S. Majumdar. Multi-center precision of cortical and trabecular bone quality measures assessed by HR-PQCT. J. Bone Miner. Res. 28(3):524–536, 2013.
Burghardt, A. J., H. R. Buie, A. Laib, S. Majumdar, and S. K. Boyd. Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT. Bone 47(3):519–528, 2010.
Burghardt, A. J., G. J. Kazakia, and S. Majumdar. A local adaptive threshold strategy for high resolution peripheral quantitative computed tomography of trabecular bone. Ann. Biomed. Eng. 35(10):1678–1686, 2007.
Burghardt, A. J., G. J. Kazakia, S. Ramachandran, T. M. Link, and S. Majumdar. Age- and gender-related differences in the geometric properties and biomechanical significance of intracortical porosity in the distal radius and tibia. J. Bone Miner. Res. 25(5):983–993, 2010.
Burrows, M., D. Liu, and H. McKay. High-resolution peripheral QCT imaging of bone micro-structure in adolescents. Osteoporos. Int. 21(3):515–520, 2010.
Dalzell, N., S. Kaptoge, N. Morris, A. Berthier, B. Koller, L. Braak, B. van Rietbergen, and J. Reeve. Bone micro-architecture and determinants of strength in the radius and tibia: age-related changes in a population-based study of normal adults measured with high-resolution pQCT. Osteoporos. Int. 20(10):1683–1694, 2009.
Edmonds, J., and M. Lassere. Imaging damage: scoring versus measuring. J. Rheumatol. 28(8):1749–1751, 2001.
Engelke, K., B. Stampa, W. Timm, B. Dardzinski, A. E. de Papp, H. K. Genant, and T. Fuerst. Short-term in vivo precision of BMD and parameters of trabecular architecture at the distal forearm and tibia. Osteoporos. Int. 23(8):2151–2158, 2012.
Feldkamp, L. A., L. C. Davis, and J. W. Kress. Practical cone-beam algorithm. J. Opt. Soc. Am. A: 1:612–619, 1984.
Finzel, S., M. Englbrecht, K. Engelke, C. Stach, and G. Schett. A comparative study of periarticular bone lesions in rheumatoid arthritis and psoriatic arthritis. Ann. Rheum. Dis. 70(1):122–127, 2011.
Fouque-Aubert, A., S. Boutroy, H. Marotte, N. Vilayphiou, E. Lespessailles, C. L. Benhamou, P. Miossec, and R. Chapurlat. Assessment of hand trabecular bone texture with high resolution direct digital radiograph in rheumatoid arthritis: a case control study. Joint, Bone, Spine: revue du rhumatisme 79(4):379–383, 2012.
Hildebrand, T., and P. Ruegsegger. A new method for the model-independent assessment of thickness in three-dimensional images. J. Microsc. 185:67–75, 1997.
Khosla, S., B. L. Riggs, E. J. Atkinson, A. L. Oberg, L. J. McDaniel, M. Holets, J. M. Peterson, and L. J. Melton, 3rd. Effects of sex and age on bone microstructure at the ultradistal radius: a population-based noninvasive in vivo assessment. J. Bone Miner. Res. 21(1):124–131, 2006.
Kirmani, S., D. Christen, G. H. van Lenthe, P. R. Fischer, M. L. Bouxsein, L. K. McCready, L. J. Melton, 3rd, B. L. Riggs, S. Amin, R. Muller, and S. Khosla. Bone structure at the distal radius during adolescent growth. J. Bone Miner. Res. 24(6):1033–1042, 2009.
Laib, A., H. J. Hauselmann, and P. Ruegsegger. In vivo high resolution 3D-QCT of the human forearm. Technol. Health Care 6(5–6):329–337, 1998.
Laib, A., and P. Ruegsegger. Comparison of structure extraction methods for in vivo trabecular bone measurements. Comput. Med. Imaging Graph. 23(2):69–74, 1999.
Landewe, R., and D. van der Heijde. Joint space narrowing, cartilage and physical function: are we deceived by measurements and distributions? Ann. Rheum. Dis. 70(5):717–718, 2011.
Lassere, M., M. Boers, D. van der Heijde, A. Boonen, J. Edmonds, A. Saudan, and A. C. Verhoeven. Smallest detectable difference in radiological progression. J. Rheumatol. 26(3):731–739, 1999.
Liu, X. S., X. H. Zhang, K. K. Sekhon, M. F. Adams, D. J. McMahon, J. P. Bilezikian, E. Shane, and X. E. Guo. High-resolution peripheral quantitative computed tomography can assess microstructural and mechanical properties of human distal tibial bone. J. Bone Miner. Res. 25(4):746–756, 2010.
Macdonald, H. M., K. K. Nishiyama, J. Kang, D. A. Hanley, and S. K. Boyd. Age-related patterns of trabecular and cortical bone loss differ between sexes and skeletal sites: a population-based HR-pQCT study. J. Bone Miner. Res. 26(1):50–62, 2011.
MacNeil, J. A., and S. K. Boyd. Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med. Eng. Phys. 29(10):1096–1105, 2007.
Macneil, J. A., and S. K. Boyd. Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method. Bone 42(6):1203–1213, 2008.
MacNeil, J. A., and S. K. Boyd. Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med. Eng. Phys. 30(6):792–799, 2008.
Pauchard, Y., A. M. Liphardt, H. M. Macdonald, D. A. Hanley, and S. K. Boyd. Quality control for bone quality parameters affected by subject motion in high-resolution peripheral quantitative computed tomography. Bone 50(6):1304–1310, 2012.
Peloschek, P., G. Langs, M. Weber, J. Sailer, M. Reisegger, H. Imhof, H. Bischof, and F. Kainberger. An automatic model-based system for joint space measurements on hand radiographs: initial experience. Radiology 245(3):855–862, 2007.
Pialat, J. B., A. J. Burghardt, M. Sode, T. M. Link, and S. Majumdar. Visual grading of motion induced image degradation in high resolution peripheral computed tomography: impact of image quality on measures of bone density and micro-architecture. Bone 50(1):111–118, 2012.
Sharp, J. T., J. Angwin, M. Boers, J. Duryea, A. Finckh, J. R. Hall, J. A. Kauffman, R. Landewe, G. Langs, C. Lukas, H. J. Moens, P. Peloschek, C. V. Strand, and D. van der Heijde. Multiple computer-based methods of measuring joint space width can discriminate between treatment arms in the COBRA trial—update of an ongoing OMERACT project. J. Rheumatol. 36(8):1825–1828, 2009.
Sharp, J. T., J. Angwin, M. Boers, J. Duryea, G. von Ingersleben, J. R. Hall, J. A. Kauffman, R. Landewe, G. Langs, C. Lukas, J. F. Maillefert, H. J. Bernelot Moens, P. Peloschek, V. Strand, and D. van der Heijde. Computer based methods for measurement of joint space width: update of an ongoing OMERACT project. J. Rheumatol. 34(4):874–883, 2007.
Sharp, J. T., D. van der Heijde, J. Angwin, J. Duryea, H. J. Moens, J. W. Jacobs, J. F. Maillefert, and C. V. Strand. Measurement of joint space width and erosion size. J. Rheumatol. 32(12):2456–2461, 2005.
Sode, M., A. J. Burghardt, J. B. Pialat, T. M. Link, and S. Majumdar. Quantitative characterization of subject motion in HR-pQCT images of the distal radius and tibia. Bone 48(6):1291–1297, 2011.
Sornay-Rendu, E., S. Boutroy, F. Munoz, and P. D. Delmas. Alterations of cortical and trabecular architecture are associated with fractures in postmenopausal women, partially independent of decreased BMD measured by DXA: the OFELY study. J. Bone Miner. Res. 22(3):425–433, 2007.
Srikhum, W., W. Virayavanich, A. J. Burghardt, A. Yu, T. M. Link, J. B. Imboden, and X. Li. Quantitative and semiquantitative bone erosion assessment on high-resolution peripheral quantitative computed tomography in rheumatoid arthritis. J. Rheumatol. 40(4):408–416, 2013.
Stach, C. M., M. Bauerle, M. Englbrecht, G. Kronke, K. Engelke, B. Manger, and G. Schett. Periarticular bone structure in rheumatoid arthritis patients and healthy individuals assessed by high-resolution computed tomography. Arthritis Rheum. 62(2):330–339, 2010.
Stein, E. M., X. S. Liu, T. L. Nickolas, A. Cohen, V. Thomas, D. J. McMahon, C. Zhang, P. T. Yin, F. Cosman, J. Nieves, X. E. Guo, and E. Shane. Abnormal microarchitecture and reduced stiffness at the radius and tibia in postmenopausal women with fractures. J. Bone Miner. Res. 25(12):2572–2581, 2010.
Tjong, W., G. J. Kazakia, A. J. Burghardt, and S. Majumdar. The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure. Med. Phys. 39(4):1893–1903, 2012.
van der Heijde, D. How to read radiographs according to the Sharp/van der Heijde method. J. Rheumatol. 27(1):261–263, 2000.
Vico, L., M. Zouch, A. Amirouche, D. Frere, N. Laroche, B. Koller, A. Laib, T. Thomas, and C. Alexandre. High-resolution pQCT analysis at the distal radius and tibia discriminates patients with recent wrist and femoral neck fractures. J. Bone Miner. Res. 23(11):1741–1750, 2008.
Zhu, T. Y., J. F. Griffith, L. Qin, V. W. Hung, T. N. Fong, S. K. Au, X. L. Tang, A. W. Kwok, P. C. Leung, E. K. Li, and L. S. Tam. Structure and strength of the distal radius in female patients with rheumatoid arthritis: a case-control study. J. Bone Miner. Res. 28(4):794–806, 2013.
Acknowledgments
The authors would like to thank Melissa Guan, Thelma Munoz, and Gus Del Puerto for coordinating subject recruitment, and translation assistance. Furthermore they thank Dr. Miki Sode, Ph.D. and Steve Rock for the design and construction of the forearm cast used for MCP imaging. This study was supported with funds from a UCSF Academic Senate Grant (XL), NIH R01 AG17762 (SM), and NIH R01 AR060700 (AJB).
Author information
Authors and Affiliations
Corresponding author
Additional information
Associate Editor Joel D. Stitzel oversaw the review of this article.
Rights and permissions
About this article
Cite this article
Burghardt, A.J., Lee, C.H., Kuo, D. et al. Quantitative In Vivo HR-pQCT Imaging of 3D Wrist and Metacarpophalangeal Joint Space Width in Rheumatoid Arthritis. Ann Biomed Eng 41, 2553–2564 (2013). https://doi.org/10.1007/s10439-013-0871-x
Received:
Accepted:
Published:
Issue Date: