Skip to main content
Log in

Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath

  • Review
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The selected ion flow tube (SIFT) technique for trace gas analysis of air and breath is based on soft chemical ionisation of the trace gases to the exclusion of the major air and breath gases, in fast-flowing inert carrier gas, exploiting the ion-molecule reactions that occur between the trace gases and the pre selected precursor ions (H3O+, NO+ and O +2 ). The physics and ion chemistry involved in the SIFT technique are described, as are the kinetics of the ion-molecule reactions that are exploited to quantitatively analyse the trace gases. Fast on-line data-acquisition hardware and software have been developed to analyse the mass spectra obtained, from which partial pressures of the trace gases down to about 10 parts per billion can be measured. The time response of the instrument is 20 ms, allowing the profiles of the trace gas concentrations on breath to be obtained during a normal breathing cycle. Pilot results obtained with this SIFT technique include detection and quantification of the most abundant breath trace gases, analysis of cigarette smoke, detection of gases present on smokers' breath and accurate measurement of the partial pressures of NH3, NO and NO2 in air. The simultaneous analysis of several breath trace gases during a single exhalation is clearly demonstrated, and thus different elution times for isoprene and methanol along the respiratory tract are observed. This technique has great potential in many clinical and biological disciplines, and in health and safety monitoring.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ausloos, P. (Ed.) (1975): “Interactions between ions and molecules” (Plenum, New York)

    Google Scholar 

  • Ferguson, E.E., Fehsenfeld, F.C., andSchmeltekopf A.L. (1969): “Flowing afterglow measurements of ion-neutral reactions”,Adv. Atom. Mol. Phys.,5, pp. 1–56

    Google Scholar 

  • Gelmont, D., Stein, R.A., andMead, J.F. (1981): “Isoprene—the main hydrocarbon in human breath”,Biochem. Biophys. Res. Commun.,99, pp. 1456–1460

    Article  Google Scholar 

  • Ikezoe, Y., Matsuoka, S., Takebe, M., andViggiano, A.A. (1987): “Gas phase reaction rate constants through 1986” (Maruzen, Tokyo)

    Google Scholar 

  • Kebarle, P. (1988): “Pulsed electron high pressure mass spectrometer”Farrar, J. M., andSaunders Jr. (Eds.): “Techniques for the study of ion-molecule reactions” (Wiley, New York), Chap. 5, pp. 221–286

    Google Scholar 

  • Kharitonov, S.A., Yates, D., andBarnes, P.J. (1995): “Increased nitric oxide in exhaled air of normal human subjects with upper respiratory tract infections”,Eur. Respir. J.,8, pp. 295–297

    Article  Google Scholar 

  • Kohlmuller, D., andKochen, W. (1993): “Is n-pentrine really an index of lipid peroxidation in humans and animals? A methodological revelation”,Anal. Biochem.,210, pp. 268–276

    Article  Google Scholar 

  • Lagg, D., Taucher, J., Hansel, A., andLindingef, W. (1994): “Applications of proton transfer reactions to gas analysis”,Int. J. Mass Spectrom. Ion Process.,134, pp. 55–66

    Article  Google Scholar 

  • Lias, D. R. (Ed.) (1991): “CRC handbook of chemistry and physics” (CRC, Boca Raton)Manolis, A. (1983): “The diagnostic potential of breath analysis”,Clin. Chem.,29, pp. 5–15

    Google Scholar 

  • Lide D. R. (Ed.) (1991): ‘CRC handbook of chemistry and physics’ (CRC, Boca Raton)

    Google Scholar 

  • Manolis, A. (1983): ‘The diagnostic potential of breath analysis’,Clin. Chem.,29, pp. 5–15

    Google Scholar 

  • McDaniel, E.W., andMason, E.A. (1973): “The mobility and diffusion of ions in gases” (Wiley, New York)

    Google Scholar 

  • Phillips, M. (1992): “Breath tests in medicine”,Sci. Am., pp. 52–57

  • Phillips, M., andGreenberg, J. (1992): “Ion-trap detection of volatile organic compounds in alveolar breath”,Clin. Chem.,38, pp. 60–65

    Google Scholar 

  • Smith, D., andAdams, N.G. (1980): “Elementary plasma reactions of environmental interest”,Top. Cirr. Chem.,89, pp. 1–43

    Google Scholar 

  • Smith, D., Adams, N.G., andAlge, E. (1981): “Ion-ion mutual neutralization and ion-neutral switching reactions of some stratospheric ions”,Planet. Space Sci Chem.,29, pp. 449–454

    Article  Google Scholar 

  • Smith, D., andAdams, N.G. (1984): “Elementary interactions between charged and neutral species in plasmas”,Pure Appl. Chem.,56, pp. 175–188

    Google Scholar 

  • Smith, D., andAdams, N.G. (1987): “The selected ion flow tube (SIFT): studies of ion-neutral reactions”,Adv. Atom. Mol. Phys.,24, pp. 1–49

    Article  Google Scholar 

  • Smith, D. (1992): “The ion chemistry of interstellar clouds”,Chem. Rev.,92, pp. 1473–1485

    Article  Google Scholar 

  • Smith, D., andSpanel, P. (1992): “Studies of interstellar ion reactions using the SIFT technique: isotope fractionation”,Acc. Chem. Res.,25, pp. 414–420

    Article  Google Scholar 

  • Smith, D., andSpanel, P. (1994): “Studies of electron attachment at thermal energies using the flowing afterglow/Langmuir probe technique”,Adv. Atom. Mol. Opt. Phys.,32, pp. 307–343

    Google Scholar 

  • Smith, D., andSpanel, P. (1995): “Swarm techniques” InDunning, F.B. (Ed.): “Experimental methods in the physical sciences: atomic, molecular, and optical physics: charges particles” (Academic Press, New York) p. 273

    Google Scholar 

  • Smith, D., andSpanel, P. (1996): “Application of ion chemistry and the SIFT technique to the quantitative analysis of trace gases in air on breath”,Int. Rev. Phys. Chem.,15, pp. 231–271

    Article  Google Scholar 

  • Spanel, P., andSmith, D. (1995): “Reactions of hydrated hydronium ions and hydrated hydroxide ions with some hydrocarbons and oxygen-bearing organic molecules”,J. Phys. Chem.,99, pp. 15551–15556

    Article  Google Scholar 

  • Spanel, P., Pavlik, M., andSmith, D. (1995): “Reactions of H3O+ and OH+ ions with some organic molecules; applications to trace gas analysis in air”,Int. J. Mass Spectrom. Ion. Process.,145, pp. 177–186

    Article  Google Scholar 

  • Spanel, P., andSmith, D. (1996): “A selected ion flow tube study of the reactions of NO+ and O2 + ions with some organic molecules: The potential for trace gas analysis of air”,J. Chem. Phys.,104, pp. 1893–1899

    Article  Google Scholar 

  • Spanel, P., Cocker, J., andSmith, D. (1996a): “Validation of the SIFT technique for trace gas analysis using the syringe injection method”,Ann. Occup. Hyg.

  • Spanel, P., Rolfe, P., Rajan, B., andSmith, D. (1996b): “The selected ion flow tube (SIFT)—a novel technique for biological monitoring”,Ibid. Ann. Occup. Hyg.

  • Su, T., andChesnavich, W.J. (1982): “Parametrization of the ion-polar molecule collision rate constant by trajectory calculations”,J. Chem. Phys.,76, pp. 5183–5186

    Article  Google Scholar 

  • Viehland, L.A., andMason, E.A. (1995): “Transportation properties of gaseous ions over a wide energy range, IV”,Atomic Data Nuclear Data Tables.,60, pp. 37–95

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Španěl, P., Smith, D. Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath. Med. Biol. Eng. Comput. 34, 409–419 (1996). https://doi.org/10.1007/BF02523843

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02523843

Keywords

Navigation