Abstract
The laser-Doppler method is frequently used in clinical experiments for blood perfusion measurement. A multichannel laser-Doppler probe was constructed, and calibrated and evaluated using a flow model and real examination of healthy subjects. Results obtained on a three-capillary flow model suggest that the probe can be used to obtain information from superficial and deeper layers of the tissue. The influence of the optical arrangement of the laser-Doppler probe on the parameters of post-occlusive reactive hyperaemia was investigated in a group of 15 healthy subjects. A statistically significant increase of biological zero with distance between emitting and detecting fibres was noted.
Similar content being viewed by others
References
Anderson, R. R. andParrish, J. A. (1981): ‘The optics of human skin’,J. Invest. Dermatol.,77, pp. 13–19.
Arridge, S. R., Cope, M. andDelpy, D. T. (1992): ‘The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysis’,Phys. Med. Biol.,37, pp. 1531–1560
Bangs, L. B. (1987): ‘Uniform latex particles’, Seradyn Inc., Indianapolis
Bonner, R. andNossal, R. (1981): ‘Model for laser Doppler measurements of blood flow in tissue’,Appl. Opt.,20, pp. 2097–2106
Caspary, L., Creutzig, A. andAlexander, K. (1988): ‘Biological zero in laser Doppler fluxmetry’,Int. J. Microcirc.,7, pp. 367–371
Colantuoni, A., Bertuglia, S. andIntaglietta, M. (1993): ‘Biological zero of laser-Doppler fluxmetry: microcirculatory correlates in the hamster cheek pouch during flow and no flow conditions’,Int. J. Microcirc. Clin. Exp.,13, pp. 125–136
Delguercio, R. M., Leonardo, G. andArpaia, M. R. (1986): ‘Evaluation of postischemic hyperemia on the skin using laser Doppler velocimetry: Study on patients with claudicatio intermittens’,Microvasc. Res.,32, pp. 289–299
Delpy, D., Cope, M., Van Der Zee, P., Arridge, S., Wray, S. andWyatt, J. (1988): ‘Estimation of optical path length’,Phys. Med. Biol.,33, pp. 1433–1442
Duteil, L., Bernengo, J. andSchalla, W. (1985): ‘A double wavelength laser Doppler system to investigate skin microcirculation’IEEE Trans. Biomed. Eng.,BME-32, pp. 439–447
Fagrell, B. (1990): ‘Peripheral vascular disorders’, inShepherd, A. P. andOberg, P. A. (Eds) ‘Laser-Doppler blood flowmetry’, (Kluwer), pp. 201–214.
Fagrell, B. (1994): ‘Problems using laser Doppler on the skin in clinical practice’, inBelcaro, G., Hoffman, U., Bollinger, A. andNicolaides, A. (Eds.), ‘Laser-Doppler’ (MED-ORION, London) pp. 49–54
Fibre Optics Centre (1995): Technical data
Gush, R. J., King, T. A. andJayson, M. I. V. (1984): ‘Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement’,Phys. Med. Biol.,29, pp. 1463–1476
Gush, R. andKing, T. (1991): ‘Discrimination of capillary and arterio-venular blood flow in skin by laser Doppler flowmetry’,Med. Biol. Eng. Comput.,29, pp. 387–392
Harris, F. J. (1978): ‘On the use of windows for harmonic analysis with the discrete Fourier transform’,Proc. IEEE,66, pp. 51–83
Hirata, K., Nagasaka, T. andNoda, Y. (1988): ‘Partitional measurement of capillary and arteriovenous anastomotic blood flow in the human finger by laser-Doppler-flowmeter’,Eur. J. Appl. Physiol.,57, pp. 616–621
Jakobsson, A. andNilsson, G. (1993): ‘Prediction of sampling depth and photon pathlength in laser Doppler flowmetry’,Med. Biol. Eng. Comput.,31, pp. 301–307
Jentink, H. W., De Mul, F. F. M., Hermsen, R. G. A. M., Graaff, R. andGreve, J. (1990): ‘Monte Carlo simulations of laser Doppler blood flow measurements in tissue’,Appl. Opt.,29, pp. 2371–2381
Jentink, H. W., deMul, F. F. M., Graaff, R., Suichies, H. E., Aarnoudse, J. G. andGreve, J. (1991): ‘Laser Doppler flowmetry: measurements in a layered perfusion model and Monte Carlo simulations of measurements’,Appl. Opt.,30, pp. 2592–2597
Johansson, K., Jakobsson, A., Lindahl, K., Lindhagen, J., Lundgren, O. andNilsson, G. E. (1991): ‘Influence of fiber diameter and probe geometry on the measuring depth of laser Doppler flowmetry in the gastrointestinal application’,Int. J. Microcirc. Clin. Exp.,10, pp. 219–229
Kvernebo, K., Slasgsvold, C. andStranden, M. (1989): ‘Laser-Doppler flowmetry in evaluation of skin post-ischaemic reactive hyperaemia’,J. Cardiovasc. Surg. 30, pp. 70–75
Liebert, A., Leahy, M. andManiewski, R. (1995): ‘A calibration standard for laser-Doppler measurements’,Rev. Sci. Instr. 66, pp. 5169–5173
Nagasaka, T., Hirata, K. andNunomura, T. (1987): ‘Contribution of arteriovenous anastomoses to vasoconstriction induced by local heating of the human finger’,Jpn. J. Physiol.,37, pp. 425–433
Obeid, A., Bogget, D., Barnett, N., Dougherty, G. andRolfe, P. (1988): ‘Depth discrimination in laser Doppler skin blood flow measurement using different lasers’,Med. Biol. Eng. Comput.,26, pp. 415–419
Öberg, P. A. (1990): ‘Laser-Doppler flowmetry’,Crit. Rev. Biomed. Eng.,18, pp. 125–163
Oxford Optronix (1994): Technical data
Wahlberg, E., Olofsson, P., Swedenborg, J. andFagrell, B. (1992): ‘Effects of local hyperemia and edema on the biological zero in laser doppler fluxmetry (LD)’,Int. J. Microcirc.,11, pp. 157–165
Ward, G. (1995): ‘Laser Doppler flowmetry: theoretical and in vitro models with red and green lasers’. Doctoral thesis, Oxford Brookes University, Oxford
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Liebert, A., Leahy, M. & Maniewski, R. Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination. Med. Biol. Eng. Comput. 36, 740–747 (1998). https://doi.org/10.1007/BF02518878
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02518878