Importance of calibration for diameter and area determination by intravascular ultrasound

  • Articles
  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Background: Intravascular ultrasound (IVUS) permits quantitative assessment of the lumen diameter and area of coronary arteries. The experimental study was performed to evaluate the accuracy of diameter and area measurements.Methods and results: Lumen quantitation (lumen diameter D and cross-sectional area A) in lucite tubes (lumen diameter 2.5 to 5.7 mm, Plexiglasℳ) was performed using a mechanical IVUS system (HP console, 3.5F catheter, Boston Scientific, 30 MHz). The influence of fluid type (blood, water and saline solution), fluid temperature (20°C/37°C), catheter to catheter variation, gain setting and ultrasound frequency (12, 20 and 30 MHz) was determined. In blood at 20°C there was a constant deviation of the measured diameter from the true luminal diameter of −0.29 ± −0.04 mm (p<0.06). In water and saline solution at 20°C the mean deviation from true diameter was −0.21 ± −0.06 mm (p<0.06). At 37°C, the deviation in blood was greater than at 20° (−0.34 ± −0.02 mm) which is >10% in a 3mm tube (p<0.06). Three of the ten catheters tested in water at 20°C underestimated true diameter by more than −0.3 mm. The deviation from true diameter (5mm tube) with varying gain settings was −0.14 mm to −0.23 mm compared to −0.19 mm at standard settings (p>0.288). At 12 MHz diameter measured was over-estimated. The error in absolute area estimation increased with increasing diameter tested in blood at 37°C (−1.21 to −2,72mm2), whereas the relative error ([Measured Area-True Area]/True Area × 100 [%]) was more striking at smaller diameters (up to −25% in the 2.5 mm tube).Conclusion: Luminal diameters and areas are underestimated by this particular IVUS system. When IVUS imaging and measurements are made during coronary interventions this error should be taken into account with regard to appropriate sizing of the device and the assessment of the postprocedure result. Because systematic errors might also occur in other IVUS systems (not tested in this study), it is advisable to ensure that each system is validated prior to clinical use, especially when exact measurements are required.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Di Mario C, The SHK, Madretsma S, Van Suylen RJ, Wilson RA, Bom N, Serruys PW, Gussenhoven EJ, Roelandt JRTC. Detection and characterization of vascular lesions by intravascular ultrasound: an in vitro study correlated with histology. J Am Soc Echocardiogr 1992; 5: 135–146.

    Google Scholar 

  2. Nissen SE, Gurley JC, Grines CL, Booth DC, McClure R, Berk M, Fischer C, DeMaria AN. Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation 1991; 84: 1087–1099.

    Google Scholar 

  3. Waller BF, Pinkerton CA, Slack JD. Intravascular ultrasound: A histological study of vessels during live — The new ‘Gold standard’ for vascular imaging. Circulation 1992; 85: 2305–2309.

    Google Scholar 

  4. Wells PNT. Physical principles in ultrasonic diagnostic. London, Academic Press; 1977.

    Google Scholar 

  5. Goss SA, Johnston RL, Dunn F. Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. J Acoust Soc Am 1978; 64: 423–480.

    Google Scholar 

  6. St. Goar FG, Pinto FJ, Aldermann EL, Fitzgerald PJ, Stinson EB, Billingham EB, Popp RL. Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound. Circulation 1992; 86: 756–763.

    Google Scholar 

  7. Fitzgerald PJ, Yock PG. Mechanisms and outcomes of angioplasty and atherectomy assessed by intravascular ultrasound imaging. J Clin Ultrasound 1993; 21: 579–588.

    Google Scholar 

  8. Pandian NG, Kreis A, O'Donnell T. Intravascular ultrasound estimation of arterial stenosis. J Am Soc Echocardiogr 1989; 2: 390–397.

    Google Scholar 

  9. Gussenhoven EJ, Frietmann PA, The SA, van-Suylen RJ, van Egmond FC, Lancee CT, van Urk H, Roelanndt JR, Stijnen T, Bom N. Assessment of medial thinning in atherosclerosis by intravascular ultrasound. Am J Cardiol 1991; 68 1625–1632.

    Google Scholar 

  10. Ge J, Erbel R, Trautmann S, Gerber T, Seidel I, Brennecke R, Meyer J. Influence of catheter design on accuracy of intravascular ultrasound. Eur Heart J 1992; 13: 394. Abstract

    Google Scholar 

  11. Ge J, Erbel R, Seidel I, Görge G, Reichert T, Gerber T, Meyer J. Experimentelle Überprüfung der Genauigkeit und Sicherheit des intraluminalen Ultraschalls. Z Kardiol 1991; 80: 595–601.

    Google Scholar 

  12. Anderson MH, Simpson IA, Katritsis D, Davies MJ, Ward DE. Intravascular ultrasound imaging of the coronary arteries: an in vitro evaluation of measurement of area of the lumen and atheroma characterisation. Br Heart J 1992; 68: 276–281.

    Google Scholar 

  13. Potkin BN, Bartorelli AL, Gessert JM, Neville RF, Almagor Y, Roberts WC, Leon MB. Coronary artery imaging with intravascular high-frequency ultrasound. Circulation 1990; 81: 1575–1585.

    Google Scholar 

  14. Nishimura RA, Edwards WD, Warnes CA, Reeder GS, Holmes (Jr.) DR, Tajik AJ, Yock PG. Intravascular ultrasound imaging: In vitro validation and pathologic correlation. J Am Coll Cardiol 1990; 16: 145–154.

    Google Scholar 

  15. Gussenhoven EJ, Essed CE, Lancée CTMastik F, Frietman P, Van Egmond FC, Reiber J, Bosch H, Van Urk H, Roelandt J, Bom N. Arterial wall characteristics determined by intravascular ultrasound: an in vitro study. J Am Coll Cardiol 1989; 14: 947–952.

    Google Scholar 

  16. Bartorelli AL, Neville RF, Keren G, Potkin BN, Almagor Y, Bonner RF, Gessert JM, Leon MB. In vitro and in vivo intravascular ultrasound imaging. Eur Heart J 1992; 13: 102–108.

    Google Scholar 

  17. Kraß S, Brennecke R, Voigtländer T, Stähr P, Rupprecht HJ, Meyer J. Assessment of image quality of intracoronary ultrasound systems with tissue-equivalent vessel phantoms. Bethesda: IEEE Computer Society Press, 1994; 289–292.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This paper is followed by an Editorial Comment written by V. Bhargava et al. (see pp. 231–232).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stähr, P., Rupprecht, HJ., Voigtländer, T. et al. Importance of calibration for diameter and area determination by intravascular ultrasound. Int J Cardiac Imag 12, 221–229 (1996). https://doi.org/10.1007/BF01797734

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01797734

Key words

Navigation