Skip to main content
Log in

The thermodilution method for the clinical assessment of cardiac output

  • Review Article
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Conclusion

The thermodilution technique has been shown to measure cardiac output accurately if flow is stationary. During mechanical ventilation the technique can be liable to gross errors. However, if certain precautions are followed mean cardiac output can be accurately estimated, even with a theoretical misuse of the Stewart-Hamilton equation. This can be done best by averaging three or four measurements equally spread over the ventilatory cycle. For this approach manufacturers of cardiac output computers have to be persuaded to include a phase selector and an automatic injector.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Fegler G (1954) Measurement of cardiac output in anaesthetised animals by a thermodilution method. Q J Exp Physiol 39:153–164

    Google Scholar 

  2. American Edwards Laboratories COM-2. Cardiac Output Computer Operations Manual 1989

  3. Medley RS, DeLapp TD, Fisher DG (1992) Comparability of the thermodilution cardiac output method: proximal injectate versus proximal infusion lumens. Heart Lung 21:12–17

    Google Scholar 

  4. Pesola GR, Carlon G (1991) Thermodilution cardiac output: proximal lumen versus right ventricular port. Crit Care Med 19:563–565

    Google Scholar 

  5. Cockroft S, Withington PS (1993) The measurement of right ventricular ejection fraction by thermodilution. A comparison of values obtained using different injectate ports. Anaesthesia 48:312–314

    Google Scholar 

  6. Pesola HR, Pesola GR (1993) Room-temperature thermodilution cardiac output. Central venous vs side port. Chest 103:339–341

    Google Scholar 

  7. Bears MG, Yonutas DN, Allen WT (1982) A complication with thermodilution cardiac outputs in centrally-placed pulmonary artery catheters. Chest 81:527–528

    Google Scholar 

  8. Bryant GH, Cucinell SA, Barcia PJ (1985) Determination of heat gain in the inferior vena cava during thermodilution measurements. J Surg Res 39:224–229

    Google Scholar 

  9. Elkayam U, Berkly R, Azen S, Weber L, Geva B, Henry WL (1983) Cardiac output by thermodilution technique. Effect of injectate's volume and temperature on accuracy and reproducibility in the critically ill patient. Chest 84:418–422

    Google Scholar 

  10. Shellock FG, Riedinger MS, Bateman TM (1983) Thermodilution cardiac output determination in hypothermic postcardiac surgery patients: room vs. iced temperature injectate. Crit Care Med 11:668–670

    Google Scholar 

  11. Pearl RG, Rosenthal MH, Nielson L, Ashton JP, Brown BW Jr (1986) Effect of injectate volume and temperature on thermodilution cardiac output determination. Anesthesiology 64:798–801

    Google Scholar 

  12. Renner LE, Morton MJ, Sakuma GY (1993) Indicator amount, temperature, an intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility. Crit Care Med 21:586–597

    Google Scholar 

  13. Wallace DC, Winslow EH (1993) Effects of iced and room temperature injectate on cardiac output measurements in critically ill patients with low and high cardiac outputs. Heart Lung 22:55–63

    Google Scholar 

  14. Todd MM (1993) Atrial fibrillation induced by right atrial injection of cold fluid during thermodilution cardiac output determination: a case report. Anesthesiology 59:253–255

    Google Scholar 

  15. Levett JM, Replogle RL (1979) Thermodilution cardiac output: a critical analysis and review of literature. J Surg Res 27:392–404

    Google Scholar 

  16. Jansen JRC, Schreuder JJ, Settels JJ, Kloek JJ, Versprille A (1990) An adequate strategy for the thermodilution technique in patients during mechanical ventilation. Intensive Care Med 16: 422–425

    Google Scholar 

  17. Jansen JRC, Wesseling KH, Settels JJ, Schreuder JJ (1990) Continuous cardiac output monitoring by pulse contour during cardiac surgery. Eur Heart J 11:26–32

    Google Scholar 

  18. Nelson LD, Houtchens BA (1982) Automatic vs manual injections for thermodilution cardiac output determinations. Crit Care Med 10:190–192

    Google Scholar 

  19. Trush DN, Varlotta D (1992) Thermodilution cardiac output: comparison between automated and manual injection of indicator. J Cardiothorac Vasc Anesth 6:17–19

    Google Scholar 

  20. Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ (1993) Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 74:2566–2573

    Google Scholar 

  21. Yonkman CA, Hamory BH (1994) Comparison of three methods of maintaining a sterile injectate system during cardiac output determinations. Am J Infect Control 12:276–281

    Google Scholar 

  22. Nelson LD, Martinez OV, Anderson HB (1986) Incidence of microbial colonization in open versus closed delivery systems for thermodilution injectate. Crit Care Med 14:291–295

    Google Scholar 

  23. Burke KG, Larson E, Maciorawski L (1986) Evaluation of the sterility of thermodilution room temperature injectate preparations. Crit Care Med 14:503–507

    Google Scholar 

  24. Cigarroa RG, Lange RA, Williams RH, Bedotto JB, Hillis LD (1989) Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 86:417–420

    Google Scholar 

  25. Ganz W, Swan HJC (1972) Measurement of bloodflow by thermodilution. Am J Cardiol 29:241–246

    Google Scholar 

  26. Wessel HU, Paul MH, James GW, Grahn AR (1971) Limitations of thermal dilution curves for cardiac output determinations. J Appl Physiol 30: 643–652

    Google Scholar 

  27. Jansen JRC, Schreuder JJ, Bogaard JM, v Rooyen W, Versprille A (1981) The thermodilution technique for the measurement of cardiac output during artificial ventilation. J Appl Physiol 51:584–591

    Google Scholar 

  28. Jansen JRC, Versprille A (1986) Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation. Intensive Care Med 12:71–79

    Google Scholar 

  29. Bazaral MG, Petre J, Novoa R (1992) Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anesthesiology 77:31–37

    Google Scholar 

  30. Latson TW, Whitten CW, O'Flaherty D (1993) Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 79:1233–1243

    Google Scholar 

  31. Hoffman JIE, Guz A, Charlier AA, Wilcken DEL (1965) Stroke volume in conscious dogs: effect of respiration, posture and vascular occlusion. J Appl Physiol 20:865–877

    Google Scholar 

  32. Morgan BC, Martin WE, Hornbein TF, Crawford EW, Fronek A (1966) Hemodynamic effects of intermittent positive pressure ventilation with and without an end-expiratory pause. Anesthesiology 27:584–590

    Google Scholar 

  33. Snyder JV, Powner DJ (1982) Effects of mechanical ventilation on the measurement of cardiac output by thermodilution. Crit Care Med 10:677–682

    Google Scholar 

  34. Okamoto K, Komatsu T, Kumar V, Sanchala V, Kabul K, Bhalodia R, Shibutani K (1986) Effects of intermitent positive-pressure ventilation on cardiac output measurements by thermodilution. Crit Care Med 14:977–980

    Google Scholar 

  35. Stetz CW, Miller RG, Kelly GE (1982) Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 125:1001–1004

    Google Scholar 

  36. Stevens JH, Raffin TA, Mihm FG, Rosenthal MH, Stetz CW (1985) Thermodilution cardiac output measurement. Effect of the respiratory cycle on its reproducibility. JAMA 253: 2240–2242

    Google Scholar 

  37. Bassingthwaighte JB, Knopp TJ, Anderson DU (1970) Flow estimation by indicator dilution. (Bolus injection): Reduction of errors due to time-averaged sampling during unsteady flow. Circ Res 27:277–291

    Google Scholar 

  38. Versprille A, Jansen JRC (1985) Mean systemic filling pressure as a characteristic pressure for venous return. Pflügers Arch 405:226–271

    Google Scholar 

  39. Jansen JRC, Bogaard JM, Versprille A (1987) Extrapolation of thermodilution curves obtained during a pause in artificial ventilation. J Appl Physiol 63: 1551–1557

    Google Scholar 

  40. Versprille A, Jansen JRC (1993) Tidal variation of pulmonary blood flow and blood volume in piglets during mechanical ventilation during hyper-, normo- and hypovolaemia. Pflügers Arch Eur J Physiol 424:255–265

    Google Scholar 

  41. Keianen O, Takala J, Kari A (1992) Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care. Crit Care Med 20:360–365

    Google Scholar 

  42. Heerdt PM, Pond CG, Blession GA, Rosenbloom M (1992) Comparison of cardiac output measured by intrapulmonary artery Doppler, thermodilution, and electromagnetometry. Ann Thorac Surg 54:959–966

    Google Scholar 

  43. Yelderman ML, Ramsey MA, Quinn MD, Paulsen AW, McKown RC, Gillman PH (1992) Continuous thermodilution cardiac output measurement in intensive care unit patients. J Cardiothorac Vasc Anesth 6:270–274

    Google Scholar 

  44. Lichtenthal PR, Wade LD (1993) Accuracy of the Vigilance/Intellicath continuous cardiac output system during and after cardiac surgery. Anesthesiology V79, No 3A, Abstract A474, September

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jansen, J.R.C. The thermodilution method for the clinical assessment of cardiac output. Intensive Care Med 21, 691–697 (1995). https://doi.org/10.1007/BF01711553

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01711553

Keywords

Navigation