Purpose

Following percutaneous lung biopsy (PLB), we used fibrin glue as a sealant in 26 patients for the purpose of decreasing the incidence of pneumothorax.

Methods

All 26 patients (group A) had chronic obstructive pulmonary disease (COPD). The results for group A were compared with a control group of 32 patients (group B), also with COPD and in whom fibrin glue was not used. All biopsies were conducted under computed tomography (CT) using a coaxial needle system consisting of 19-gauge and 22-gauge needles.

Results

Pneumothorax developed in five patients (19.2%) in group A and in one instance, drainage was required (3.8%). In group B, pneumothorax developed in 13 patients (40.6%) and in six instances (18.8%) drainage was required. Comparing the use of chest-tube drainage in the two groups, a statistical significance was observed, p < 0.025. No adverse reactions related to the fibrin glue were observed.

Conclusion

Our results indicate that fibrin glue is a safe sealing material for lung PLB and serves to decrease the incidence and, in particular, the severity of pneumothorax, especially in high-risk patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Westcott JL (1988) Percutaneous transthoracic needle biopsy. Radiology 169:593–601

    Google Scholar 

  2. Perlmutt LM, Johnston WW, Dunnick RN (1989) Percutaneous transthoracic needle aspiration: A review. AJR 152:451–455

    Google Scholar 

  3. Fish GE, Stanley JH, Miller KS, Schabel SI, Sutherland SE (1988) Postbiopsy pneumothorax: Estimating the risk by chest radiography and pulmonary function tests. AJR 150:71–74

    Google Scholar 

  4. McCartney R, Tait D, Stilson M, Seidel GA (1974) A technique for the prevention of pneumothorax in pulmonary aspiration biopsy. AJR 120:872–875

    Google Scholar 

  5. Skupin A, Gomez F, Husain M, Skupin C, Bigman O (1987) Complications of transthoracic needle biopsy decreased with isobutyl-2-cyanoacrylate: A pilot study. Ann Thorac Surg 43:406–408

    Google Scholar 

  6. Engeler CE, Hunter DW, Castañeda-Zúñiga WR, Tashjian JH, Yedlicka JW, Amplatz K (1992) Pneumothorax after lung biopsy: Prevention with transpleural placement of compressed collagen foam plugs. Radiology 184:787–789

    Google Scholar 

  7. Petsas T, Fezoulidis I, Siamblis D, Dimopoulos I (1990) Die Verwendung von homologem geronnenem, Blut zur Pneumothoraxprophylaxe nach perkutaner Lungenbiopsies: (Experimentelle Studie). Fortschr Roentgenstr 152:565–568

    Google Scholar 

  8. Bourgouin P, Shepard J-A, McLoud T, Spirany D, Dedrick C (1988) Transthoracic needle aspiration biopsy: Evaluation of the blood patch technique. Radiology 166:93–95

    Google Scholar 

  9. Herman SJ, Weisbrod LG (1990) Usefulness of the blood patch technique after transthoracic needle aspiration biopsy. Radiology 176:395–397

    Google Scholar 

  10. Fezoulidis I, Petsas T, Zavras G, Dougenis D, Michail A, Kelekis D (1993) Pneumothoraxprophylaxe mit geronnenem Blut nach perkutaner Lungenbiopsie. Fortschr Roentgenstr 159:562–563

    Google Scholar 

  11. Scott SM (1991) The pleura. In: Sabiston DC (ed) Textbook of Surgery: The Biological Basis of Modern Surgical Practice. 14th ed. W.B. Saunders Co, Philadelphia. pp 1718–1723

    Google Scholar 

  12. Poe RH, Kallay MC, Wicks CM, Odoroff CL (1984) Predicting risk of pneumothorax in needle biopsy of the lung. Chest 85:232–234

    Google Scholar 

  13. Suprenant EL (1989) Transthoracic needle aspiration biopsy: Evaluation of the blood patch technique (letter). Radiology 168:285

    Google Scholar 

  14. Rodriguez-Fuchs CA, Bruno M (1987) Plugging liver biopsy sites with coagulation factors. Lancet 2:1087

    Google Scholar 

  15. Chisholm RA, Jones SN, Lees WR (1989) Fibrin sealant as a plug for the post-liver biopsy needle track. Clin Radiol 40:627–628

    Google Scholar 

  16. Clausen JL (1990) The diagnosis of emphysema, chronic bronchitis and asthma. Clin Chest Med 11:405–416

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Petsas, T., Siamblis, D., Giannakenas, C. et al. fibrin glue for sealing the needle track in fine-needle percutaneous lung biopsy using a coaxial system: Part II—clinical study. Cardiovasc Intervent Radiol 18, 378–382 (1995). https://doi.org/10.1007/BF00338305

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00338305

Key words

Navigation