Estimation of chromium-51 ethylene diamine tetra-acetic acid plasma clearance: a comparative assessment of simplified techniques

  • Original Articles
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) total plasma clearance was evaluated using a multi-sample method (i.e. 12 blood samples) as the reference compared with several simplified methods which necessitated only one or few blood samples. The following 5 methods were evaluated: terminal slope-intercept method with 3 blood samples, simplified method of Bröchner-Mortensen and 3 single-sample methods (Constable, Christensen and Groth, Tauxe). Linear regression analysis was performed. Standard error of estimate, bias and imprecision of different methods were evaluated. For 51Cr-EDTA total plasma clearance greater than 30 ml · min−1, the results which most approximated the reference source were obtained by the Christensen and Groth method at a sampling time of 300 min (inaccuracy of 4.9%). For clearances between 10 and 30 ml · min−1, single-sample methods failed to give reliable results. Terminal slope-intercept and Bröchner-Mortensen methods were better, with inaccuracies of 17.7% and 16.9%, respectively. Although sampling times at 180, 240 and 300 min are time-consuming for patients, 51Cr-EDTA total plasma clearance can be accurately calculated for values greater than 10 ml · min−1 using the Bröchner-Mortensen method. In patients with clearance greater than 30 ml · min−1, single-sample techniques provide a good alternative to the multi-sample method; the choice of the method to be used depends on the degree of accuracy required.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Brauner L, Westling H (1981) On the necessity of strict bed rest during determination of 51Cr-EDTA clearance. Clin Physiol 1:175–180

    Google Scholar 

  • Bröchner-Mortensen J (1972) A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 30:271–274

    Google Scholar 

  • Bröchner-Mortensen J (1978) Routine methods and their reliability for assessment of glomerular filtration rate in adults. Dan Med Bull 25:181–202

    Google Scholar 

  • Bröchner-Mortensen J (1985) Current status on assessment and measurement of glomerular filtration rate. Clin Physiol 5:1–17

    Google Scholar 

  • Bröchner-Mortensen J, Rödbro P (1976a) Selection of routine method for determination of glomerular filtration rate in adult patients. Scand J Clin Lab Invest 36:35–43

    Google Scholar 

  • Bröchner-Mortensen J, Rödbro P (1976b) Comparison between total and renal plasma clearance of (51Cr)EDTA. Scand J Clin Lab Invest 36:247–249

    Google Scholar 

  • Bröchner-Mortensen J, Giese J, Rossing N (1969) Renal inulin clearance versus total plasma clearance of Cr51-EDTA. Scand J Clin Lab Invest 23:301–305

    Google Scholar 

  • Chantler C, Garnett ES, Parsons V, Veall N (1969) Glomerular filtration rate measurement in man by the single injection method using Cr51-EDTA. Clin Sci 37:169–180

    Google Scholar 

  • Christensen AB, Groth S (1986) Determination of Tc99m-DTPA clearance by a single plasma sample method. Clin Physiol 6:579–588

    Google Scholar 

  • Constable AR, Hussein MM, Albrecht MP, Thompson FD, Philalithis PE, Joekes AM (1979) Single sample estimates of renal clearance. Br J Urol 51:84–87

    Google Scholar 

  • DuBois EF (1927) Basal metabolism in health and disease. Lea & Febiger, Philadelphia

    Google Scholar 

  • Fisher M, Veall N (1975) Glomerular filtration rate estimation based on a single blood sample. BMJ 11:542

    Google Scholar 

  • Garnett ES, Parsons V, Veall N (1967) Measurement of glomerular filtration rate in man using Cr51 edetic acid complex. Lancet 1:818–819

    Google Scholar 

  • Gore SM, Atlman DG (1985) La statistica nella pratica medica. II Pensiero Scientifico Editore, Roma

    Google Scholar 

  • Groth S, Aasted R (1981) 51Cr-EDTA clearance determined by one plasma sample. Clin Physiol 1:417–425

    CAS  PubMed  Google Scholar 

  • Hagstam KE, Nordenfelt I, Svensson L, Svensson SE (1974) Comparison of different methods for determination of glomerular filtration rate in renal disease. Scand J Clin Lab Invest 34:31–36

    Google Scholar 

  • Ingram D, Bloch R (1984) Methematical methods in medicine. John Wiley, Chichester

    Google Scholar 

  • Jacobsson L (1983) A method for the calculation of renal clearance based on a single plasma sample. Clin Physiol 3:297–305

    Google Scholar 

  • Newman EV, Bordley J, Winternitz J (1944) The interrelationships of glomerular filtration rate (mannitol clearance), extracellular fluid volume, surface area of the body and plasma concentration of mannitol. Bull Johns Hopk Hosp 75:253–268

    Google Scholar 

  • Nosslin B (1965) Determination of clearance and distribution volume with the single-injection technique. Acta Med Scand 179 [Suppl 442]:97–101

    Google Scholar 

  • Rehling M, Raböl A (1989) Measurement of glomerular filtration rate in adults: accuracy of five single sample plasma clearance methods. Clin Physiol 9:171–182

    Google Scholar 

  • Russel CD, Dubovsky EV (1989) Measurement of renal function with radionuclides. J Nucl Med 30:2053–2057

    Google Scholar 

  • Summerville DA, Potter CS, Treves ST (1990) The use of radiopharmaceuticals in the measurement of glomerular filtration rate: a review. In: Freeman LM (ed) Nuclear medicine annual 1990. Raven, New York, pp 191–221

    Google Scholar 

  • Tauxe WN (1986) Determination of glomerular filtration rate by single-plasma sampling technique following injection of radioiodinated diatrizoate. J Nucl Med 27:45–50

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Offprint request to: G. Picciotto

Rights and permissions

Reprints and permissions

About this article

Cite this article

Picciotto, G., Cacace, G., Cesana, P. et al. Estimation of chromium-51 ethylene diamine tetra-acetic acid plasma clearance: a comparative assessment of simplified techniques. Eur J Nucl Med 19, 30–35 (1992). https://doi.org/10.1007/BF00178305

Download citation

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00178305

Key words

Navigation