Abstract
Hemodynamic monitoring is a central component of the overall management approach to the critically ill patient. Hemodynamic monitoring of critically ill patients has a dual function. First, it can be used to document hemodynamic stability and the lack of need for acute therapeutic interventions. Second, through monitoring we can measure variables and define the degree to which they vary from their baseline values. Thus, hemodynamic monitoring must be able to define both stability and change.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Bellomo R, Pinsky MR (1996) Invasive monitoring. In: Tinker J, Browne D, Sibbald W (eds) Critical Care-Standards, Audit and Ethics. Arnold Publishing Company, London, pp 82–104
Pinsky MR (2007) Hemodynamic evaluation and monitoring in the ICU. Chest 123: 2020–2029
Michard F, Boussat S, Chemla D, et al (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162: 134–138
Pinsky MR, Payen D (2005) Functional hemodynamic monitoring. Crit Care 9: 566–572
Hadian M, Pinsky MR (2007) Functional hemodynamic monitoring. Curr Opin Crit Care 13: 318–323
Lopes MR, Oliveira MA, Pereira VO, Lemos IPB, Auler JO Jr, Michard F (2007) Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 11:R100–107
Pinsky MR (2002) Functional hemodynamic monitoring. Intensive Care Med 28: 386–388
Monnet X, Rienzo M, Osman D, et al (2006) Response to leg raising predicts fluid responsiveness in critically ill. Crit Care Med 34: 1402–1407
Pinsky MR, Vincent J-L (2005) Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med 33: 1119–1122
Skarda DE, Mulier KE, Myers DE, Taylor JH, Beilman GJ (2007) Dynamic near-infrared spectroscopy measurements in patients with severe sepsis. Shock 27: 348–353
Gómez H, Torres A, Zenker S, et al (2008) Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O(2) saturation response. Intensive Care Med 34: 1600–1607
Pinsky MR (1998) Controlled observations in critical care medicine: The therapeutic trial. Ann Acad Med Singapore 27: 387–396
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Pinsky, M.R. (2009). Functional Hemodynamic Monitoring: A Personal Perspective. In: Vincent, JL. (eds) Yearbook of Intensive Care and Emergency Medicine. Yearbook of Intensive Care and Emergency Medicine, vol 2009. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-92276-6_29
Download citation
DOI: https://doi.org/10.1007/978-3-540-92276-6_29
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-92275-9
Online ISBN: 978-3-540-92276-6
eBook Packages: MedicineMedicine (R0)