Precision measurements of alternating currents up to 2000 amperes

Published under licence by IOP Publishing Ltd
, , Citation A H M Arnold 1931 J. Sci. Instrum. 8 154 DOI 10.1088/0950-7671/8/5/303

0950-7671/8/5/154

Abstract

Figures are given of the performance of a current transformer with nickel iron core, having a ratio 2000/1, operating on a burden of 100 volt-amperes at rated current. The ratio is within 3 parts in 10,000 of its nominal value in the frequency range 25 cycles per second to 100 cycles per second at full current to one-tenth of full current.

In conjunction with a non-inductive resistance of accurately known value and an electrostatic voltmeter, the transformer may be used for measuring currents up to 2000 amperes with an accuracy of a few parts in 10,000.