Visual outcome after monocular implantation of extended depth of focus intraocular lens in a patient with iridodialysis: a case report and literature review

Authors: Edward Tran, Nirmit Shah, Angela Kyveris, Toby Yiu Bong Chan

Published in: Journal of Medical Case Reports | Issue 1/2024

Login to get access

Abstract

Background

Iridodialysis, the separation of the iris root from the ciliary body, typically results from trauma and can lead to significant visual impairment. This case report is novel as it demonstrates the successful management of iridodialysis using an extended depth of focus intraocular lens in a patient with a slightly irregular pupil.

Case presentation

A 34-year-old Hispanic man presented with reduced vision and pain in his right eye following blunt trauma from a nail at work. Examination revealed a small temporal corneal stromal scar, traumatic posterior subcapsular cataract, two inferior iridodialysis defects, and a superiorly displaced dyscoric oval pupil. Snellen uncorrected distance visual acuity was 20/400. The patient opted for an extended depth of focus intraocular lens implantation to meet his visual demands for distance and intermediate vision without glasses. Cataract surgery with capsular tension ring, extended depth of focus intraocular lens implantation, iridodialysis repair, and suture pupilloplasty were performed uneventfully. At 1 month postoperatively, uncorrected distance visual acuity improved to 20/40, while uncorrected intermediate visual acuity and uncorrected near visual acuity were 20/20. A central, relatively round, and slightly inferiorly peaked pupil was achieved. A steroid response intraocular pressure rise at postoperative month 2 required intraocular pressure-lowering medications, and symptomatic posterior capsular opacity developed at 8 months postoperatively. At 11 months postoperatively, selective laser trabeculoplasty and laser capsulotomy were performed. At 4-year follow-up, visual acuity measurements remained stable, and intraocular pressure was normal without any medication. The patient was satisfied with the visual and cosmetic outcomes.

Conclusion

This case demonstrates that extended depth of focus intraocular lenses can be a viable option for patients with slightly irregular pupils following suture repair of the iris and pupil. The successful visual and cosmetic outcomes in this patient suggest that extended depth of focus intraocular lenses may be considered in similar complex cases, providing a balance of near, intermediate, and distance vision without significant visual disturbances.
Literature
1.
go back to reference Paton D, Craig J. Management of iridodialysis. Ophthalmic Surg. 1973;4:38–9. Paton D, Craig J. Management of iridodialysis. Ophthalmic Surg. 1973;4:38–9.
3.
go back to reference Pandav S, Gupta S, Singh R, Das K, Kaushik S, Raj S, Ram J. Cobbler’s technique for iridodialysis repair. Middle East Afr J Ophthalmol. 2016;23:142–4.CrossRefPubMedPubMedCentral Pandav S, Gupta S, Singh R, Das K, Kaushik S, Raj S, Ram J. Cobbler’s technique for iridodialysis repair. Middle East Afr J Ophthalmol. 2016;23:142–4.CrossRefPubMedPubMedCentral
4.
go back to reference Wachler BB, Krueger RR. Double-armed McCannell suture for repair of traumatic iridodialysis. Am J Ophthalmol. 1996;122:109–10.CrossRefPubMed Wachler BB, Krueger RR. Double-armed McCannell suture for repair of traumatic iridodialysis. Am J Ophthalmol. 1996;122:109–10.CrossRefPubMed
5.
go back to reference Huang JY, Liu YL. A novel technique for closed-chamber iridodialysis repair. Taiwan J Ophthalmol. 2020;10:208–11.CrossRefPubMed Huang JY, Liu YL. A novel technique for closed-chamber iridodialysis repair. Taiwan J Ophthalmol. 2020;10:208–11.CrossRefPubMed
6.
go back to reference Loiudice P, Casini G. Post-traumatic iridodialysis, crystalline dislocation and vitreous haemorrhage: How to manage. BMJ Case Rep. 2014;2014: bcr2014205595.CrossRefPubMedPubMedCentral Loiudice P, Casini G. Post-traumatic iridodialysis, crystalline dislocation and vitreous haemorrhage: How to manage. BMJ Case Rep. 2014;2014: bcr2014205595.CrossRefPubMedPubMedCentral
8.
go back to reference Chuang LH, Lai CC. Secondary intraocular lens implantation of traumatic cataract in open-globe injury. Can J Ophthalmol. 2005;40:454–9.CrossRefPubMed Chuang LH, Lai CC. Secondary intraocular lens implantation of traumatic cataract in open-globe injury. Can J Ophthalmol. 2005;40:454–9.CrossRefPubMed
9.
go back to reference Lončar VL, Petric I. Surgical treatment, clinical outcomes, and complications of traumatic cataract: retrospective study. Croat Med J. 2004;45:310–3. Lončar VL, Petric I. Surgical treatment, clinical outcomes, and complications of traumatic cataract: retrospective study. Croat Med J. 2004;45:310–3.
10.
go back to reference Kuhn F. Editorial: traumatic cataract: what, when, how. Graefes Arch Clin Exp Ophthalmol. 2010;248:1221–3.CrossRefPubMed Kuhn F. Editorial: traumatic cataract: what, when, how. Graefes Arch Clin Exp Ophthalmol. 2010;248:1221–3.CrossRefPubMed
11.
12.
go back to reference Fernández J, Rodríguez-Vallejo M, Martínez J, Burguera N, Piñero DP. Pupil dependence assessment with multifocal intraocular lenses through visual acuity and contrast sensitivity defocus curves. Eur J Ophthalmol. 2020;31:2989–96.CrossRefPubMed Fernández J, Rodríguez-Vallejo M, Martínez J, Burguera N, Piñero DP. Pupil dependence assessment with multifocal intraocular lenses through visual acuity and contrast sensitivity defocus curves. Eur J Ophthalmol. 2020;31:2989–96.CrossRefPubMed
13.
go back to reference Rampat R, Gatinel D. Multifocal and extended depth-of-focus intraocular lenses in 2020. Ophthalmology. 2020;128: e164.CrossRefPubMed Rampat R, Gatinel D. Multifocal and extended depth-of-focus intraocular lenses in 2020. Ophthalmology. 2020;128: e164.CrossRefPubMed
14.
go back to reference Breyer DRH, Kaymak H, Ax T, Kretz FTA, Auffarth GU, Hagen PR. Multifocal intraocular lenses and extended depth of focus intraocular lenses. Asia-Pac J Ophthalmol. 2017;6:339–49. Breyer DRH, Kaymak H, Ax T, Kretz FTA, Auffarth GU, Hagen PR. Multifocal intraocular lenses and extended depth of focus intraocular lenses. Asia-Pac J Ophthalmol. 2017;6:339–49.
15.
go back to reference Cochener B. Clinical outcomes of a new extended range of vision intraocular lens: international multicenter concerto study. J Cataract Refract Surg. 2016;42:1268–75.CrossRefPubMed Cochener B. Clinical outcomes of a new extended range of vision intraocular lens: international multicenter concerto study. J Cataract Refract Surg. 2016;42:1268–75.CrossRefPubMed
16.
go back to reference Abbott Medical Optics Inc. TECNIS Symfony Extended Range of Vision IOL. Z310939, Rev. 03. 2014. Abbott Medical Optics Inc. TECNIS Symfony Extended Range of Vision IOL. Z310939, Rev. 03. 2014.
18.
go back to reference Gramatikov BI, Irsch K, Guyton D. Optimal timing of retinal scanning during dark adaptation, in the presence of fixation on a target: the role of pupil size dynamics. J Biomed Opt. 2014;19:1–3.CrossRef Gramatikov BI, Irsch K, Guyton D. Optimal timing of retinal scanning during dark adaptation, in the presence of fixation on a target: the role of pupil size dynamics. J Biomed Opt. 2014;19:1–3.CrossRef
19.
go back to reference Mathôt S. Tuning the senses: how the pupil shapes vision at the earliest stage. Annu Rev Vis Sci. 2020;6:433–51.CrossRefPubMed Mathôt S. Tuning the senses: how the pupil shapes vision at the earliest stage. Annu Rev Vis Sci. 2020;6:433–51.CrossRefPubMed
20.
go back to reference Ripps H, Chin NB, Siegel IM, Breinin GM. The effect of pupil size on accommodation. Investig Ophthalmol Vis. 1976;16:587–9. Ripps H, Chin NB, Siegel IM, Breinin GM. The effect of pupil size on accommodation. Investig Ophthalmol Vis. 1976;16:587–9.
21.
go back to reference Woodhouse JM. The effect of pupil size on grating detection at various contrast levels. Vision Res. 1975;15:645–8.CrossRefPubMed Woodhouse JM. The effect of pupil size on grating detection at various contrast levels. Vision Res. 1975;15:645–8.CrossRefPubMed
22.
go back to reference Bang SP, Jun JH. Iris reconstruction using autologous iris preserved in cold balanced salt solution for 8 hours in iatrogenic total iridodialysis during cataract surgery: a case report. BMC Ophthalmol. 2017;17:1–4.CrossRef Bang SP, Jun JH. Iris reconstruction using autologous iris preserved in cold balanced salt solution for 8 hours in iatrogenic total iridodialysis during cataract surgery: a case report. BMC Ophthalmol. 2017;17:1–4.CrossRef
23.
go back to reference Wan W, Shi L, Li C. Comparing safety and efficiency of two closed-chamber techniques for iridodialysis repair - a retrospective clinical study. BMC Ophthalmol. 2018;18:4–9.CrossRef Wan W, Shi L, Li C. Comparing safety and efficiency of two closed-chamber techniques for iridodialysis repair - a retrospective clinical study. BMC Ophthalmol. 2018;18:4–9.CrossRef
24.
go back to reference Khokhar S, Gupta S, Kumar G. Iridodialysis repair: stroke and dock technique. Int Ophthalmol. 2014;34:331–5.CrossRefPubMed Khokhar S, Gupta S, Kumar G. Iridodialysis repair: stroke and dock technique. Int Ophthalmol. 2014;34:331–5.CrossRefPubMed
25.
go back to reference Xiang W, Zhong X, Chen H, Chen W, Chen W. Pupilloplasty by radiofrequency diathermy. Acta Ophthalmol. 2019;97:479–81.CrossRef Xiang W, Zhong X, Chen H, Chen W, Chen W. Pupilloplasty by radiofrequency diathermy. Acta Ophthalmol. 2019;97:479–81.CrossRef
26.
go back to reference Phylactou M, Matarazzo F, Day AC, Hussain B, Maurino V. Cataract surgery in eyes with congenital ocular coloboma. Graefes Arch Clin Exp Ophthalmol. 2020;258:2753–9.CrossRefPubMed Phylactou M, Matarazzo F, Day AC, Hussain B, Maurino V. Cataract surgery in eyes with congenital ocular coloboma. Graefes Arch Clin Exp Ophthalmol. 2020;258:2753–9.CrossRefPubMed
28.
go back to reference Hoffman RS, Fine IH, Packer M. Refractive lens exchange with a multifocal intraocular lens. Curr Opin Ophthalmol. 2003;14:24–30.CrossRefPubMed Hoffman RS, Fine IH, Packer M. Refractive lens exchange with a multifocal intraocular lens. Curr Opin Ophthalmol. 2003;14:24–30.CrossRefPubMed
29.
go back to reference Montes-Mico R, Ferrer-Blasco T, Charman WN, Cervino A, Alfonso JF, et al. Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens. J Cataract Refract Surg. 2008;34:763–8.CrossRefPubMed Montes-Mico R, Ferrer-Blasco T, Charman WN, Cervino A, Alfonso JF, et al. Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens. J Cataract Refract Surg. 2008;34:763–8.CrossRefPubMed
30.
go back to reference Lichtinger A, Rootman DS. Intraocular lenses for presbyopia correction: past, present, and future. Curr Opin Ophthalmol. 2012;23:40–6.CrossRefPubMed Lichtinger A, Rootman DS. Intraocular lenses for presbyopia correction: past, present, and future. Curr Opin Ophthalmol. 2012;23:40–6.CrossRefPubMed
31.
go back to reference Mullie GA, Chan TYB. Visual outcome after bilateral implantation of extended depth of focus intraocular lens in a patient with iris microhemangiomas. Clin Exp Ophthalmol. 2017;8:8–11. Mullie GA, Chan TYB. Visual outcome after bilateral implantation of extended depth of focus intraocular lens in a patient with iris microhemangiomas. Clin Exp Ophthalmol. 2017;8:8–11.
Metadata
Title
Visual outcome after monocular implantation of extended depth of focus intraocular lens in a patient with iridodialysis: a case report and literature review
Authors
Edward Tran
Nirmit Shah
Angela Kyveris
Toby Yiu Bong Chan
Publication date
01-12-2024
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2024
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-024-04899-0