Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO)
- Open Access
- 01-12-2017
- Case Study
- Authors
- Roman Scheidmann
- Thomas Paul
- Matthias Sigler
- Published in
- Molecular and Cellular Pediatrics | Issue 1/2017
Abstract
Introduction
Transcatheter closure has become the treatment of choice for secundum atrial septal defects (ASD II), but particularly in small children, there is concern regarding procedure-related complications.
Case description
We report on a 10-month-old infant, body weight of 6.4 kg, with a large ASD who was referred for failure to thrive and dyspnea on exertion. Echocardiography showed two neighboring ASDs centrally located within an atrial septum with a length of 27 mm resulting in significant left-to-right shunting. During cardiac catheterization, hemodynamic significance of the defect as well as normal pulmonary vascular resistance was demonstrated. Balloon sizing of the central ASD showed a stretched defect diameter of 12 × 11 mm. A 20-mm GORE CARDIOFORM septal occluder (GCSO; Goremedical, W. L. Gore & Associates, Inc., Newark, DE, USA) was implanted without any complications. Initial trivial residual shunting resolved during 4 months of follow-up. Right ventricular dimensions declined significantly, and the boy gained body weight properly.
Discussion, evaluation and conclusion
As demonstrated in our report, even large ASDs can be closed safely by catheter intervention in small infants. Selection of implant device and optimal sizing is of paramount importance. The size of the delivery sheath (11 French in our patient) is a potential limitation for the GCSO in smaller infants.
Advertisement
- Title
- Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO)
- Authors
-
Roman Scheidmann
Thomas Paul
Matthias Sigler
- Publication date
- 01-12-2017
- Publisher
- Springer Berlin Heidelberg
- Published in
-
Molecular and Cellular Pediatrics / Issue 1/2017
Electronic ISSN: 2194-7791 - DOI
- https://doi.org/10.1186/s40348-017-0077-7
This content is only visible if you are logged in and have the appropriate permissions.