Accuracy of remote, video-based supraventricular tachycardia detection in patients undergoing elective electrical cardioversion: a prospective cohort

Authors: Iris Cramer, Rik van Esch, Cindy Verstappen, Carla Kloeze, Bas van Bussel, Sander Stuijk, Jan Bergmans, Marcel van ’t Veer, Svitlana Zinger, Leon Montenij, R. Arthur Bouwman, Lukas Dekker

Published in: Journal of Clinical Monitoring and Computing

Login to get access

Abstract

Unobtrusive pulse rate monitoring by continuous video recording, based on remote photoplethysmography (rPPG), might enable early detection of perioperative arrhythmias in general ward patients. However, the accuracy of an rPPG-based machine learning model to monitor the pulse rate during sinus rhythm and arrhythmias is unknown. We conducted a prospective, observational diagnostic study in a cohort with a high prevalence of arrhythmias (patients undergoing elective electrical cardioversion). Pulse rate was assessed with rPPG via a visible light camera and ECG as reference, before and after cardioversion. A cardiologist categorized ECGs into normal sinus rhythm or arrhythmias requiring further investigation. A supervised machine learning model (support vector machine with Gaussian kernel) was trained using rPPG signal features from 60-s intervals and validated via leave-one-subject-out. Pulse rate measurement performance was evaluated with Bland–Altman analysis. Of 72 patients screened, 51 patients were included in the analyses, including 444 60-s intervals with normal sinus rhythm and 1130 60-s intervals of clinically relevant arrhythmias. The model showed robust discrimination (AUC 0.95 [0.93–0.96]) and good calibration. For pulse rate measurement, the bias and limits of agreement for sinus rhythm were 1.21 [− 8.60 to 11.02], while for arrhythmia, they were − 7.45 [− 35.75 to 20.86]. The machine learning model accurately identified sinus rhythm and arrhythmias using rPPG in real-world conditions. Heart rate underestimation during arrhythmias highlights the need for optimization.
Appendix
Available only for authorised users
Literature
1.
go back to reference International Surgical Outcomes Study group. Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries. Br J Anaesth. 2016;117:601–9.CrossRef International Surgical Outcomes Study group. Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries. Br J Anaesth. 2016;117:601–9.CrossRef
4.
5.
go back to reference Eddahchouri Y, Koeneman M, Plokker M, Brouwer E, van de Belt TH, van Goor H, et al. Low compliance to a vital sign safety protocol on general hospital wards: a retrospective cohort study. Int J Nurs Stud. 2021;115:103849.CrossRefPubMed Eddahchouri Y, Koeneman M, Plokker M, Brouwer E, van de Belt TH, van Goor H, et al. Low compliance to a vital sign safety protocol on general hospital wards: a retrospective cohort study. Int J Nurs Stud. 2021;115:103849.CrossRefPubMed
6.
go back to reference Mestrom E, De Bie A, van de Steeg M, Driessen M, Atallah L, Bezemer R, et al. Implementation of an automated early warning scoring system in a surgical ward: practical use and effects on patient outcomes. PLoS ONE. 2019;14:e0213402.CrossRefPubMedPubMedCentral Mestrom E, De Bie A, van de Steeg M, Driessen M, Atallah L, Bezemer R, et al. Implementation of an automated early warning scoring system in a surgical ward: practical use and effects on patient outcomes. PLoS ONE. 2019;14:e0213402.CrossRefPubMedPubMedCentral
7.
go back to reference Churpek MM, Yuen TC, Huber MT, Park SY, Hall JB, Edelson DP. Predicting cardiac arrest on the wards. Chest. 2012;141:1170–6.CrossRefPubMed Churpek MM, Yuen TC, Huber MT, Park SY, Hall JB, Edelson DP. Predicting cardiac arrest on the wards. Chest. 2012;141:1170–6.CrossRefPubMed
8.
go back to reference Bautista MJ, Kowal M, Cave DGW, Downey C, Jayne DG. Clinical applications of contactless photoplethysmography for monitoring in adults: a systematic review and meta-analysis. J Clin Transl Sci. 2023;7:e129.CrossRefPubMedPubMedCentral Bautista MJ, Kowal M, Cave DGW, Downey C, Jayne DG. Clinical applications of contactless photoplethysmography for monitoring in adults: a systematic review and meta-analysis. J Clin Transl Sci. 2023;7:e129.CrossRefPubMedPubMedCentral
9.
go back to reference Leenen JPL, Leerentveld C, van Dijk JD, van Westreenen HL, Schoonhoven L, Patijn GA. Current evidence for continuous vital signs monitoring by wearable wireless devices in hospitalized adults: Systematic review [Internet]. J Med Internet Res. JMIR Publications Inc. 2020. https://pubmed.ncbi.nlm.nih.gov/32469323/. Accessed 14 Jan 2021. Leenen JPL, Leerentveld C, van Dijk JD, van Westreenen HL, Schoonhoven L, Patijn GA. Current evidence for continuous vital signs monitoring by wearable wireless devices in hospitalized adults: Systematic review [Internet]. J Med Internet Res. JMIR Publications Inc. 2020. https://​pubmed.​ncbi.​nlm.​nih.​gov/​32469323/​. Accessed 14 Jan 2021.
10.
go back to reference Wang W, Den Brinker AC, Stuijk S, De Haan G. Algorithmic principles of remote PPG. IEEE Trans Biomed Eng. 2017;64:1479–91.CrossRefPubMed Wang W, Den Brinker AC, Stuijk S, De Haan G. Algorithmic principles of remote PPG. IEEE Trans Biomed Eng. 2017;64:1479–91.CrossRefPubMed
11.
go back to reference Yang Y, Sarkis RA, El AR, Loddenkemper T, Meisel C. Video-based detection of generalized tonic-clonic seizures using deep learning. IEEE J Biomed Health Inform. 2021;25:2997–3008.CrossRefPubMed Yang Y, Sarkis RA, El AR, Loddenkemper T, Meisel C. Video-based detection of generalized tonic-clonic seizures using deep learning. IEEE J Biomed Health Inform. 2021;25:2997–3008.CrossRefPubMed
12.
go back to reference Jorge J, Villarroel M, Tomlinson H, Gibson O, Darbyshire JL, Ede J, et al. Non-contact physiological monitoring of post-operative patients in the intensive care unit. NPJ Digit Med. 2022;5:4.CrossRefPubMedPubMedCentral Jorge J, Villarroel M, Tomlinson H, Gibson O, Darbyshire JL, Ede J, et al. Non-contact physiological monitoring of post-operative patients in the intensive care unit. NPJ Digit Med. 2022;5:4.CrossRefPubMedPubMedCentral
13.
go back to reference Cox EGM, van Bussel BCT, Campillo Llamazares N, Sels J-WEM, Onrust M, van der Horst ICC, et al. Facial appearance associates with longitudinal multi-organ failure: an ICU cohort study. Crit Care. 2024;28:106.CrossRefPubMedPubMedCentral Cox EGM, van Bussel BCT, Campillo Llamazares N, Sels J-WEM, Onrust M, van der Horst ICC, et al. Facial appearance associates with longitudinal multi-organ failure: an ICU cohort study. Crit Care. 2024;28:106.CrossRefPubMedPubMedCentral
15.
go back to reference Sun Y, Yang Y-Y, Wu B-J, Huang P-W, Cheng S-E, Wu B-F, et al. Contactless facial video recording with deep learning models for the detection of atrial fibrillation. Sci Rep. 2022;12:281.CrossRefPubMedPubMedCentral Sun Y, Yang Y-Y, Wu B-J, Huang P-W, Cheng S-E, Wu B-F, et al. Contactless facial video recording with deep learning models for the detection of atrial fibrillation. Sci Rep. 2022;12:281.CrossRefPubMedPubMedCentral
16.
go back to reference Couderc J-P, Kyal S, Mestha LK, Xu B, Peterson DR, Xia X, et al. Detection of atrial fibrillation using contactless facial video monitoring. Heart Rhythm. 2015;12:195–201.CrossRefPubMed Couderc J-P, Kyal S, Mestha LK, Xu B, Peterson DR, Xia X, et al. Detection of atrial fibrillation using contactless facial video monitoring. Heart Rhythm. 2015;12:195–201.CrossRefPubMed
17.
go back to reference Yan BP, Lai WHS, Chan CKY, Au ACK, Freedman B, Poh YC, et al. High-throughput, contact-free detection of atrial fibrillation from video with deep learning. JAMA Cardiol. 2020;5:105.CrossRefPubMed Yan BP, Lai WHS, Chan CKY, Au ACK, Freedman B, Poh YC, et al. High-throughput, contact-free detection of atrial fibrillation from video with deep learning. JAMA Cardiol. 2020;5:105.CrossRefPubMed
18.
go back to reference Blich M, Edoute Y. Electrical cardioversion for persistent or chronic atrial fibrillation: outcome and clinical factors predicting short and long term success rate. Int J Cardiol. 2006;107:389–94.CrossRefPubMed Blich M, Edoute Y. Electrical cardioversion for persistent or chronic atrial fibrillation: outcome and clinical factors predicting short and long term success rate. Int J Cardiol. 2006;107:389–94.CrossRefPubMed
19.
go back to reference Wang W, den Brinker AC, de Haan G. Discriminative signatures for remote-PPG. IEEE Trans Biomed Eng. 2020;67:1462–73.CrossRefPubMed Wang W, den Brinker AC, de Haan G. Discriminative signatures for remote-PPG. IEEE Trans Biomed Eng. 2020;67:1462–73.CrossRefPubMed
20.
go back to reference Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
21.
go back to reference Zou G. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual. Stat Methods Med Res. 2013;22:630–42.CrossRefPubMed Zou G. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual. Stat Methods Med Res. 2013;22:630–42.CrossRefPubMed
22.
23.
go back to reference Association for the Advancement of Medical Instrumentation. Association for the Advancement of Medical Instrumentation Cardiac monitors, heart rate meters, and alarms. 2002. Association for the Advancement of Medical Instrumentation. Association for the Advancement of Medical Instrumentation Cardiac monitors, heart rate meters, and alarms. 2002.
24.
go back to reference Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10:622–8.CrossRefPubMed Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10:622–8.CrossRefPubMed
25.
go back to reference Subbe CP. Validation of a modified early warning score in medical admissions. QJM. 2001;94:521–6.CrossRefPubMed Subbe CP. Validation of a modified early warning score in medical admissions. QJM. 2001;94:521–6.CrossRefPubMed
26.
go back to reference van Esch R, Cramer I, Li X, Verstappen C, Kloeze C, van ’t Veer M, et al. Video health monitoring for cardiac arrhythmia detection in a real hospital scenario. In: Park BJ, Yoshida H, editors. Medical Imaging 2023: Imaging Informatics for Healthcare, Research, and Applications. SPIE; 2023. p. 10. van Esch R, Cramer I, Li X, Verstappen C, Kloeze C, van ’t Veer M, et al. Video health monitoring for cardiac arrhythmia detection in a real hospital scenario. In: Park BJ, Yoshida H, editors. Medical Imaging 2023: Imaging Informatics for Healthcare, Research, and Applications. SPIE; 2023. p. 10.
29.
go back to reference Rasche S, Trumpp A, Waldow T, Gaetjen F, Plötze K, Wedekind D, et al. Camera-based photoplethysmography in critical care patients. Clin Hemorheol Microcirc. 2016;64:77–90.CrossRefPubMed Rasche S, Trumpp A, Waldow T, Gaetjen F, Plötze K, Wedekind D, et al. Camera-based photoplethysmography in critical care patients. Clin Hemorheol Microcirc. 2016;64:77–90.CrossRefPubMed
30.
go back to reference Murad MH, Lin L, Chu H, Hasan B, Alsibai RA, Abbas AS, et al. The association of sensitivity and specificity with disease prevalence: analysis of 6909 studies of diagnostic test accuracy. Can Med Assoc J. 2023;195:E925-31.CrossRef Murad MH, Lin L, Chu H, Hasan B, Alsibai RA, Abbas AS, et al. The association of sensitivity and specificity with disease prevalence: analysis of 6909 studies of diagnostic test accuracy. Can Med Assoc J. 2023;195:E925-31.CrossRef
31.
go back to reference Nowara EM, McDuff D, Veeraraghavan A. A Meta-Analysis of the Impact of Skin Type and Gender on Non-contact Photoplethysmography Measurements. 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW). IEEE; 2020. Nowara EM, McDuff D, Veeraraghavan A. A Meta-Analysis of the Impact of Skin Type and Gender on Non-contact Photoplethysmography Measurements. 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW). IEEE; 2020.
32.
go back to reference Couderc J-P, Page A, Lutz M, Tsouri GR, Hall B. Assessment of facial video-based detection of atrial fibrillation across human complexion. Cardiovasc Digit Health J. 2022;3:305–12.CrossRefPubMedPubMedCentral Couderc J-P, Page A, Lutz M, Tsouri GR, Hall B. Assessment of facial video-based detection of atrial fibrillation across human complexion. Cardiovasc Digit Health J. 2022;3:305–12.CrossRefPubMedPubMedCentral
Metadata
Title
Accuracy of remote, video-based supraventricular tachycardia detection in patients undergoing elective electrical cardioversion: a prospective cohort
Authors
Iris Cramer
Rik van Esch
Cindy Verstappen
Carla Kloeze
Bas van Bussel
Sander Stuijk
Jan Bergmans
Marcel van ’t Veer
Svitlana Zinger
Leon Montenij
R. Arthur Bouwman
Lukas Dekker
Publication date
29-01-2025
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-025-01263-5