Skip to main content
Top

Open Access 16-05-2024 | Stroke | REVIEW

Implantation of a novel insertable cardiac monitor: preliminary multicenter experience in Europe

Authors: S. Fareh, S. Nardi, L. Argenziano, A. Diamante, F. Scala, C. Mandurino, M. Magnocavallo, L. Poggio, M. Scarano, D. Gianfrancesco, F. Palma, M. S. Silvetti, D. Porcelli, M. Racheli, M. Montoy, P. Charles, M. Campari, S. Valsecchi, C. Lavalle

Published in: Journal of Interventional Cardiac Electrophysiology

Login to get access

Abstract

Background

The LUX-Dx™ is a novel insertable cardiac monitor (ICM) introduced into the European market since October 2022.

Purpose

The aim of this investigation was to provide a comprehensive description of the ICM implantation experience in Europe during its initial year of commercial use.

Methods

The system comprises an incision tool and a single-piece insertion tool pre-loaded with the small ICM. The implantation procedure involves incision, creation of a device pocket, insertion of the ICM, verification of sensing, and incision closure. Patients receive a mobile device with a preloaded App, connecting to their ICM and transmitting data to the management system. Data collected at European centers were analyzed at the time of implantation and before patient discharge.

Results

A total of 368 implantation procedures were conducted across 23 centers. Syncope (235, 64%) and cryptogenic stroke (34, 9%) were the most frequent indications for ICM. Most procedures (338, 92%) were performed in electrophysiology laboratories. All ICMs were successfully implanted in the left parasternal region, oriented at 45° in 323 (88%) patients. Repositioning was necessary after sensing verification in 9 (2%) patients. No procedural complications were reported, with a median time from skin incision to suture of 4 min (25th–75th percentiles 2–7). At implantation, the mean R-wave amplitude was 0.39 ± 0.30 mV and the P-wave visibility was 91 ± 20%. Sensing parameters remained stable until pre-discharge and were not influenced by patient characteristics or indications. Procedural times were fast, exhibited consistency across patient groups, and improved after an initial experience with the system. Operator Operator feedback on the system was positive. Patients reported very good ease of use of the App and low levels of discomfort after implantation.

Conclusions

LUX-Dx™ implantation appears efficient and straightforward, with favorable post-implantation sensing values and associated with positive feedback from operators and patients.

Graphical Abstract

Appendix
Available only for authorised users
Literature
1.
go back to reference Brignole M, Moya A, de Lange FJ, Deharo JC, Elliott PM, Fanciulli A, Fedorowski A, Furlan R, Kenny RA, Martín A, Probst V, Reed MJ, Rice CP, Sutton R, Ungar A, van Dijk JG, ESC Scientific Document Group. 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J. 2018;39:1883–948.CrossRefPubMed Brignole M, Moya A, de Lange FJ, Deharo JC, Elliott PM, Fanciulli A, Fedorowski A, Furlan R, Kenny RA, Martín A, Probst V, Reed MJ, Rice CP, Sutton R, Ungar A, van Dijk JG, ESC Scientific Document Group. 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J. 2018;39:1883–948.CrossRefPubMed
2.
go back to reference Sakhi R, Theuns DAMJ, Szili-Torok T, Yap SC. Insertable cardiac monitors: current indications and devices. Expert Rev Med Devices. 2019;16:45–55.CrossRefPubMed Sakhi R, Theuns DAMJ, Szili-Torok T, Yap SC. Insertable cardiac monitors: current indications and devices. Expert Rev Med Devices. 2019;16:45–55.CrossRefPubMed
3.
go back to reference Varma N, Cygankiewicz I, Turakhia MP, Heidbuchel H, Hu YF, Chen LY, Couderc JP, Cronin EM, Estep JD, Grieten L, Lane DA, Mehra R, Page A, Passman R, Piccini JP, Piotrowicz E, Piotrowicz R, Platonov PG, Ribeiro AL, Rich RE, Russo AM, Slotwiner D, Steinberg JS, Svennberg E. 2021 ISHNE/HRS/EHRA/APHRS expert collaborative statement on mHealth in arrhythmia management: digital medical tools for heart rhythm professionals: from the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society. Circ Arrhythm Electrophysiol. 2021;14:e009204.CrossRefPubMedPubMedCentral Varma N, Cygankiewicz I, Turakhia MP, Heidbuchel H, Hu YF, Chen LY, Couderc JP, Cronin EM, Estep JD, Grieten L, Lane DA, Mehra R, Page A, Passman R, Piccini JP, Piotrowicz E, Piotrowicz R, Platonov PG, Ribeiro AL, Rich RE, Russo AM, Slotwiner D, Steinberg JS, Svennberg E. 2021 ISHNE/HRS/EHRA/APHRS expert collaborative statement on mHealth in arrhythmia management: digital medical tools for heart rhythm professionals: from the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society. Circ Arrhythm Electrophysiol. 2021;14:e009204.CrossRefPubMedPubMedCentral
4.
go back to reference Stolen C, Rosman J, Manyam H, Kwan B, Kelly J, Perschbacher D, Garner J, Richards M. Preliminary results from the LUX-Dx insertable cardiac monitor remote programming and performance (LUX-Dx PERFORM) study. Clin Cardiol. 2023;46:100–7.CrossRefPubMed Stolen C, Rosman J, Manyam H, Kwan B, Kelly J, Perschbacher D, Garner J, Richards M. Preliminary results from the LUX-Dx insertable cardiac monitor remote programming and performance (LUX-Dx PERFORM) study. Clin Cardiol. 2023;46:100–7.CrossRefPubMed
5.
go back to reference Mahajan D, Frost K, Herrmann K, McGee-Taylor R. Real-world characterization and use of insertable cardiac monitor remote programming. J Innov Card Rhythm Manag. 2022;13:5230–5.CrossRefPubMedPubMedCentral Mahajan D, Frost K, Herrmann K, McGee-Taylor R. Real-world characterization and use of insertable cardiac monitor remote programming. J Innov Card Rhythm Manag. 2022;13:5230–5.CrossRefPubMedPubMedCentral
6.
go back to reference Sanghvi MM, Jones DM, Kalindjian J, Monkhouse C, Providencia R, Schilling RJ, Ahluwalia N, Earley MJ, Finlay M. The utility of implantable loop recorders in patient management: an age- and indication-stratified study in the outpatient-implant era. Eur Heart J Qual Care Clin Outcomes. 2022;8:770–7.CrossRefPubMed Sanghvi MM, Jones DM, Kalindjian J, Monkhouse C, Providencia R, Schilling RJ, Ahluwalia N, Earley MJ, Finlay M. The utility of implantable loop recorders in patient management: an age- and indication-stratified study in the outpatient-implant era. Eur Heart J Qual Care Clin Outcomes. 2022;8:770–7.CrossRefPubMed
7.
go back to reference Deneke T, Cabanas P, Hofer D, Gaspar T, Pierre B, Bisignani G, Pathak RK, Sanfins VM, Martens E, Mansourati J, Berruezo-Sanchez A, Wiemer M, Hain A, Pezawas T, Wenzel B, Lau D, BIO, MASTER.BIOMONITOR III study and BIO, STREAM.ICM registry investigators. New-generation miniaturized insertable cardiac monitor with a long sensing vector: insertion procedure, sensing performance, and home monitoring transmission success in a real-world population. Heart Rhythm O2. 2022;3:152–9.CrossRefPubMedPubMedCentral Deneke T, Cabanas P, Hofer D, Gaspar T, Pierre B, Bisignani G, Pathak RK, Sanfins VM, Martens E, Mansourati J, Berruezo-Sanchez A, Wiemer M, Hain A, Pezawas T, Wenzel B, Lau D, BIO, MASTER.BIOMONITOR III study and BIO, STREAM.ICM registry investigators. New-generation miniaturized insertable cardiac monitor with a long sensing vector: insertion procedure, sensing performance, and home monitoring transmission success in a real-world population. Heart Rhythm O2. 2022;3:152–9.CrossRefPubMedPubMedCentral
8.
go back to reference Maines M, Degiampietro M, Tomasi G, Poian L, Cont N, Peruzza F, Moggio P, Triglione F, Giacopelli D, Del Greco M. Strategic reprogramming of implantable cardiac monitors reduces the false-positive remote alert burden in a nurse-led service. Eur J Cardiovasc Nurs. 2023;22:773–9.CrossRefPubMed Maines M, Degiampietro M, Tomasi G, Poian L, Cont N, Peruzza F, Moggio P, Triglione F, Giacopelli D, Del Greco M. Strategic reprogramming of implantable cardiac monitors reduces the false-positive remote alert burden in a nurse-led service. Eur J Cardiovasc Nurs. 2023;22:773–9.CrossRefPubMed
9.
go back to reference Lim WY, Papageorgiou N, Sukumar SM, Alexiou S, Srinivasan NT, Monkhouse C, Daw H, Caldeira H, Harvie H, Kuriakose J, Baca M, Ahsan SY, Chow AW, Hunter RJ, Finlay M, Lambiase PD, Schilling RJ, Earley MJ, Providencia R. A nurse-led implantable loop recorder service is safe and cost effective. J Cardiovasc Electrophysiol. 2019;30:2900–6.CrossRefPubMed Lim WY, Papageorgiou N, Sukumar SM, Alexiou S, Srinivasan NT, Monkhouse C, Daw H, Caldeira H, Harvie H, Kuriakose J, Baca M, Ahsan SY, Chow AW, Hunter RJ, Finlay M, Lambiase PD, Schilling RJ, Earley MJ, Providencia R. A nurse-led implantable loop recorder service is safe and cost effective. J Cardiovasc Electrophysiol. 2019;30:2900–6.CrossRefPubMed
10.
go back to reference Dulai R, Hunt J, Veasey RA, Biyanwila C, O’Neill B, Patel N. Immediate implantable loop recorder implantation for detecting atrial fibrillation in cryptogenic stroke. J Stroke Cerebrovasc Dis. 2023;32:106988.CrossRefPubMed Dulai R, Hunt J, Veasey RA, Biyanwila C, O’Neill B, Patel N. Immediate implantable loop recorder implantation for detecting atrial fibrillation in cryptogenic stroke. J Stroke Cerebrovasc Dis. 2023;32:106988.CrossRefPubMed
11.
go back to reference Kipp R, Young N, Barnett A, Kopp D, Leal MA, Eckhardt LL, Teelin T, Hoffmayer KS, Wright J, Field M. Injectable loop recorder implantation in an ambulatory setting by advanced practice providers: analysis of outcomes. Pacing Clin Electrophysiol. 2017;40:982–5.CrossRefPubMed Kipp R, Young N, Barnett A, Kopp D, Leal MA, Eckhardt LL, Teelin T, Hoffmayer KS, Wright J, Field M. Injectable loop recorder implantation in an ambulatory setting by advanced practice providers: analysis of outcomes. Pacing Clin Electrophysiol. 2017;40:982–5.CrossRefPubMed
12.
go back to reference Wong GR, Lau DH, Middeldorp ME, Harrington JA, Stolcman S, Wilson L, Twomey DJ, Kumar S, Munawar DA, Khokhar KB, Mahajan R, Sanders P. Feasibility and safety of Reveal LINQ insertion in a sterile procedure room versus electrophysiology laboratory. Int J Cardiol. 2016;223:13–7.CrossRefPubMed Wong GR, Lau DH, Middeldorp ME, Harrington JA, Stolcman S, Wilson L, Twomey DJ, Kumar S, Munawar DA, Khokhar KB, Mahajan R, Sanders P. Feasibility and safety of Reveal LINQ insertion in a sterile procedure room versus electrophysiology laboratory. Int J Cardiol. 2016;223:13–7.CrossRefPubMed
13.
go back to reference Reinsch N, Füting A, Höwel D, Neven K. The BIOMONITOR III injectable cardiac monitor: clinical experience with a novel injectable cardiac monitor. J Clin Med. 2022;11:1634.CrossRefPubMedPubMedCentral Reinsch N, Füting A, Höwel D, Neven K. The BIOMONITOR III injectable cardiac monitor: clinical experience with a novel injectable cardiac monitor. J Clin Med. 2022;11:1634.CrossRefPubMedPubMedCentral
14.
go back to reference Mariani JA, Weerasooriya R, van den Brink O, Mohamed U, Gould PA, Pathak RK, Lin T, Conradie A, Illes P, Pavia S, Rajamani K, Lovibond S, Matthews I, DiFiore D, Arumugam D, Schrader J, Lau DH. Miniaturized implantable cardiac monitor with a long sensing vector (BIOMONITOR III): insertion procedure assessment, sensing performance, and home monitoring transmission success. J Electrocardiol. 2020;60:118–25.CrossRefPubMed Mariani JA, Weerasooriya R, van den Brink O, Mohamed U, Gould PA, Pathak RK, Lin T, Conradie A, Illes P, Pavia S, Rajamani K, Lovibond S, Matthews I, DiFiore D, Arumugam D, Schrader J, Lau DH. Miniaturized implantable cardiac monitor with a long sensing vector (BIOMONITOR III): insertion procedure assessment, sensing performance, and home monitoring transmission success. J Electrocardiol. 2020;60:118–25.CrossRefPubMed
15.
go back to reference Grubb BP, Welch M, Kanjwal K, Karabin B, Kanjwal Y. An anatomic-based approach for the placement of implantable loop recorders. Pacing Clin Electrophysiol. 2010;33:1149–52.CrossRefPubMed Grubb BP, Welch M, Kanjwal K, Karabin B, Kanjwal Y. An anatomic-based approach for the placement of implantable loop recorders. Pacing Clin Electrophysiol. 2010;33:1149–52.CrossRefPubMed
16.
go back to reference Reinsch N, Ruprecht U, Buchholz J, Diehl RR, Kälsch H, Neven K. The BioMonitor 2 insertable cardiac monitor: clinical experience with a novel implantable cardiac monitor. J Electrocardiol. 2018;51:751–5.CrossRefPubMed Reinsch N, Ruprecht U, Buchholz J, Diehl RR, Kälsch H, Neven K. The BioMonitor 2 insertable cardiac monitor: clinical experience with a novel implantable cardiac monitor. J Electrocardiol. 2018;51:751–5.CrossRefPubMed
17.
go back to reference De Coster M, Demolder A, De Meyer V, Vandenbulcke F, Van Heuverswyn F, De Pooter J. Diagnostic accuracy of R-wave detection by insertable cardiac monitors. Pacing Clin Electrophysiol. 2020;43:511–7.CrossRefPubMed De Coster M, Demolder A, De Meyer V, Vandenbulcke F, Van Heuverswyn F, De Pooter J. Diagnostic accuracy of R-wave detection by insertable cardiac monitors. Pacing Clin Electrophysiol. 2020;43:511–7.CrossRefPubMed
18.
go back to reference D’Souza R, Thomas E, Macicek S, Aziz P, Shivapour JK, Snyder C. P- and R-wave amplitude sensed by Reveal LINQ™ loop recorder in pediatric patients. J Innov Card Rhythm Manag. 2017;8:2584–8.CrossRefPubMedPubMedCentral D’Souza R, Thomas E, Macicek S, Aziz P, Shivapour JK, Snyder C. P- and R-wave amplitude sensed by Reveal LINQ™ loop recorder in pediatric patients. J Innov Card Rhythm Manag. 2017;8:2584–8.CrossRefPubMedPubMedCentral
19.
go back to reference Schreiber T, Cretnik A, Schauerte P, Lacour P, Blaschke F, Biewener S, Suhail S, Tscholl V, Nagel P, Landmesser U, Huemer M, Attanasio P. P-wave detection performance of the BioMonitor III, Confirm Rx and Reveal Linq implantable loop recorders. J Electrocardiol. 2022;71:62–6.CrossRefPubMed Schreiber T, Cretnik A, Schauerte P, Lacour P, Blaschke F, Biewener S, Suhail S, Tscholl V, Nagel P, Landmesser U, Huemer M, Attanasio P. P-wave detection performance of the BioMonitor III, Confirm Rx and Reveal Linq implantable loop recorders. J Electrocardiol. 2022;71:62–6.CrossRefPubMed
20.
go back to reference Forleo GB, Amellone C, Sacchi R, Lombardi L, Lucciola MT, Scotti V, Viecca M, Schiavone M, Giacopelli D, Giammaria M. Factors affecting signal quality in implantable cardiac monitors with long sensing vector. J Arrhythm. 2021;37:1061–8.CrossRefPubMedPubMedCentral Forleo GB, Amellone C, Sacchi R, Lombardi L, Lucciola MT, Scotti V, Viecca M, Schiavone M, Giacopelli D, Giammaria M. Factors affecting signal quality in implantable cardiac monitors with long sensing vector. J Arrhythm. 2021;37:1061–8.CrossRefPubMedPubMedCentral
21.
go back to reference O’Shea CJ, Middeldorp ME, Hendriks JM, Brooks AG, Harper C, Thomas G, Emami M, Thiyagarajah A, Feigofsky S, Gopinathannair R, Varma N, Campbell K, Lau DH, Sanders P. Remote monitoring of implantable loop recorders: false-positive alert episode burden. Circ Arrhythm Electrophysiol. 2021;14:e009635.CrossRefPubMed O’Shea CJ, Middeldorp ME, Hendriks JM, Brooks AG, Harper C, Thomas G, Emami M, Thiyagarajah A, Feigofsky S, Gopinathannair R, Varma N, Campbell K, Lau DH, Sanders P. Remote monitoring of implantable loop recorders: false-positive alert episode burden. Circ Arrhythm Electrophysiol. 2021;14:e009635.CrossRefPubMed
22.
go back to reference Neiman ZM, Raitt MH, Rohrbach G, Dhruva SS. Monitoring of remotely reprogrammable implantable loop recorders with algorithms to reduce false-positive alerts. J Am Heart Assoc. 2024;13:e032890.CrossRefPubMedPubMedCentral Neiman ZM, Raitt MH, Rohrbach G, Dhruva SS. Monitoring of remotely reprogrammable implantable loop recorders with algorithms to reduce false-positive alerts. J Am Heart Assoc. 2024;13:e032890.CrossRefPubMedPubMedCentral
23.
go back to reference Ferrick AM, Raj SR, Deneke T, Kojodjojo P, Lopez-Cabanillas N, Abe H, Boveda S, Chew DS, Choi JI, Dagres N, Dalal AS, Dechert BE, Frazier-Mills CG, Gilbert O, Han JK, Hewit S, Kneeland C, Mirza SD, Mittal S, Ricci RP, Runte M, Sinclair S, Alkmim-Teixeira R, Vandenberk B, Varma N, Davenport E, Freedenberg V, Glotzer TV, Huang JL, Ikeda T, Kramer DB, Lin D, Rojel-Martínez U, Stühlinger M, Varosy PD. HRS/EHRA/APHRS/LAHRS expert consensus statement on practical management of the remote device clinic. Europace. 2023;25:euad123.CrossRefPubMedPubMedCentral Ferrick AM, Raj SR, Deneke T, Kojodjojo P, Lopez-Cabanillas N, Abe H, Boveda S, Chew DS, Choi JI, Dagres N, Dalal AS, Dechert BE, Frazier-Mills CG, Gilbert O, Han JK, Hewit S, Kneeland C, Mirza SD, Mittal S, Ricci RP, Runte M, Sinclair S, Alkmim-Teixeira R, Vandenberk B, Varma N, Davenport E, Freedenberg V, Glotzer TV, Huang JL, Ikeda T, Kramer DB, Lin D, Rojel-Martínez U, Stühlinger M, Varosy PD. HRS/EHRA/APHRS/LAHRS expert consensus statement on practical management of the remote device clinic. Europace. 2023;25:euad123.CrossRefPubMedPubMedCentral
24.
go back to reference Chokesuwattanaskul R, Safadi AR, Ip R, Waraich HK, Hudson OM, Ip JH. Data transmission delay in Medtronic Reveal LINQ™ implantable cardiac monitor: clinical experience in 520 patients. J Biomed Sci Eng. 2019;12:391–9.CrossRef Chokesuwattanaskul R, Safadi AR, Ip R, Waraich HK, Hudson OM, Ip JH. Data transmission delay in Medtronic Reveal LINQ™ implantable cardiac monitor: clinical experience in 520 patients. J Biomed Sci Eng. 2019;12:391–9.CrossRef
25.
go back to reference Pürerfellner H, Sanders P, Pokushalov E, Di Bacco M, Bergemann T, Dekker LR, Reveal LINQ Usability Study Investigators. Miniaturized Reveal LINQ insertable cardiac monitoring system: first-in-human experience. Heart Rhythm. 2015;12:1113–9.CrossRefPubMed Pürerfellner H, Sanders P, Pokushalov E, Di Bacco M, Bergemann T, Dekker LR, Reveal LINQ Usability Study Investigators. Miniaturized Reveal LINQ insertable cardiac monitoring system: first-in-human experience. Heart Rhythm. 2015;12:1113–9.CrossRefPubMed
26.
go back to reference Krahn AD, Pickett RA, Sakaguchi S, Shaik N, Cao J, Norman HS, Guerrero P. R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: results from a multicenter clinical trial. Pacing Clin Electrophysiol. 2014;37:505–11.CrossRefPubMed Krahn AD, Pickett RA, Sakaguchi S, Shaik N, Cao J, Norman HS, Guerrero P. R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: results from a multicenter clinical trial. Pacing Clin Electrophysiol. 2014;37:505–11.CrossRefPubMed
Metadata
Title
Implantation of a novel insertable cardiac monitor: preliminary multicenter experience in Europe
Authors
S. Fareh
S. Nardi
L. Argenziano
A. Diamante
F. Scala
C. Mandurino
M. Magnocavallo
L. Poggio
M. Scarano
D. Gianfrancesco
F. Palma
M. S. Silvetti
D. Porcelli
M. Racheli
M. Montoy
P. Charles
M. Campari
S. Valsecchi
C. Lavalle
Publication date
16-05-2024
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-024-01821-y

A quick guide to ECGs

Improve your ECG interpretation skills with this comprehensive, rapid, interactive course. Expert advice provides detailed feedback as you work through 50 ECGs covering the most common cardiac presentations to ensure your practice stays up to date. 

PD Dr. Carsten W. Israel
Developed by: Springer Medizin
Start the cases

Keynote webinar | Spotlight on medication adherence

  • Webinar | 27-06-2024 | 18:00 (CEST)

Medication non-adherence is a major barrier to effective healthcare delivery; half of all patients do not follow their doctor’s recommendations or treatment plan.

Our experts explain the fundamentals with a practical discussion of how to manage non-adherence in two common scenarios: hypertension and asthma control.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Watch now