Skip to main content
Top
Published in:

Open Access 01-12-2024 | Root Canal Debridement | Research

Comparison of electronic apex locator and simultaneous working length detection methods with radiological method in terms of postoperative pain

Authors: Emine Guzel, Miray Uyan, Seyda Ersahan, Mustafa Gundogar, Fatih Ozcelik

Published in: BMC Oral Health | Issue 1/2024

Login to get access

Abstract

Background

Precise knowledge of the apical construction, which determines the end of the area for canal preparation and filling, is essential for the success of root canal treatment and the management of postoperative pain. For this purpose, devices based on various methods that determine the working length (WL) are used. However, it is still controversial which method provides the most accurate measurements.

Aim

To investigate the compatibility of the electronic apex locator (EWL) and simultaneous working length determination (SWL) methods in single-root teeth in comparison with the radiographic working length determination (RWL) method and to determine which one produced more effective results in terms of postoperative pain.

Materials & methods

One hundred patients scheduled for root canal treatment (RCT) were randomly assigned to one of the three groups according to the working length measurement method (EWL, SWL or RWL). After WL determination with assigned method, root canals were prepared and then obturated. Age, gender, simplified oral hygiene index (OHI-S), oral and dental examinations and Visual Analogue Scale (VAS) results of all participants were recorded. The incidence and intensity of postoperative pain were rated on a Visual Analogue Scale (VAS) by patients 6, 12, 24, 48 h and 7 days after RCT. The number of analgesic tablets (400 mg Ibuprofen) taken by patients was also recorded. Data were analyzed using the chi-square, One- way ANOVA and Kruskal-Wallis tests. Bland-Altman and Passing-Bablock regression analysis were used as method comparison techniques.

Results

It was determined that the number of patients receiving analgesia and the total number of analgesia doses were higher in EWL and RWL groups compared to SWL group (p < 0.0001). When the WL values at which the treatment was applied were compared in the patient groups; WL values of EWL group were statistically lower than SWL group (p < 0.01). While there was no difference between the preoperative VAS scores of the groups (p = 0.7590), the postoperative 6th and 12th hour VAS scores of SWL group were lower than those of EWL and RWL groups (p = 0.005 and p = 0.0002, respectively). Again, the VAS scores of SWL group at the 24th and 48th postoperative hours were lower than those of RWL group (p < 0.05). According to the Bland-Altman and Passing-Bablock regression analysis results, although there was no statistically significant difference between the EWL and SWL methods (p = 0.471), the bias value of -0.1190 was well below the acceptable total error (0.1648). Additionally, a strong relationship was found between EWL and SWL methods (r = 0.9698, r2 = 0.9406, p < 0.001). Therefore, statistically these two methods were considered compatible with each other. It was determined that there was a statistically significant bias (0.340, p < 0.0001) between the RWL and SWL methods, exceeding the total error.

Conclusions

As a result, it was determined that the SWL method, which is used to determine working length for the success of endodontic treatment, can be used as an alternative to the EWL method thus producing more effective results in the management of postoperative pain. However, in addition to the method used, the technology of the device developed for this method should not be ignored.

Clinical relevance

Precise knowledge of the apical construction, which determines the end of the area for canal preparation and filling, is essential for the success of root canal treatment and the management of postoperative pain. For this purpose, devices based on various methods that determine the working length are used. However, it is still controversial which method provides the most accurate measurements. This study found that the simultaneous working length determination method can be used as an alternative to the electronic working length determination method and produces more effective results in the management of postoperative pain. Another important outcome of this study is that the Total Allowable Error (TEa) for the electronic apex locator method, which is accepted as the reference, has been calculated for the first time. Other methods have been evaluated according to this reference method. This is a first in literature.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mancini M, Felici R, Conte G, Costantini M, Cianconi L. Accuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study. J Endod. 2011;37:684–87.CrossRefPubMed Mancini M, Felici R, Conte G, Costantini M, Cianconi L. Accuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study. J Endod. 2011;37:684–87.CrossRefPubMed
3.
go back to reference Kara Tuncer A, Gerek M. Effect of working length measurement by electronic apex locator or digital radiography on postoperative pain: a randomized clinical trial. J Endod. 2014;40(1):38–41.CrossRefPubMed Kara Tuncer A, Gerek M. Effect of working length measurement by electronic apex locator or digital radiography on postoperative pain: a randomized clinical trial. J Endod. 2014;40(1):38–41.CrossRefPubMed
4.
go back to reference Klemz AA, Cruz ATG, Piasecki L, Carneiro E, Westphalen VPD, da Silva Neto UX. Accuracy of electronic apical functions of a new integrated motor compared to the visual control of the working length—an ex vivo study. Clin Oral Investig. 2021;25:231–6.CrossRefPubMed Klemz AA, Cruz ATG, Piasecki L, Carneiro E, Westphalen VPD, da Silva Neto UX. Accuracy of electronic apical functions of a new integrated motor compared to the visual control of the working length—an ex vivo study. Clin Oral Investig. 2021;25:231–6.CrossRefPubMed
5.
go back to reference Orstavik D, Kerekes K, Eriksen HM. The periapical index: a scoring system for radiographic assessment of apical periodontitis. Endod Dent Traumatol. 1986;2(1):20–34.CrossRefPubMed Orstavik D, Kerekes K, Eriksen HM. The periapical index: a scoring system for radiographic assessment of apical periodontitis. Endod Dent Traumatol. 1986;2(1):20–34.CrossRefPubMed
6.
go back to reference Ingle JI, Bakland LK, Endodontics. 5th ed. Hamilton, Ontario, Canada: B. C. Decker Elsevier; 2002. Ingle JI, Bakland LK, Endodontics. 5th ed. Hamilton, Ontario, Canada: B. C. Decker Elsevier; 2002.
7.
go back to reference Delgado DA, Lambert BS, Boutris N, McCulloch PC, Robbins AB, Moreno MR, et al. Validation of digital visual analog scale pain scoring with a traditional paper-based visual analog scale in adults. J Am Acad Orthop Surg Glob Res Rev. 2018;2(3):e088.PubMedPubMedCentral Delgado DA, Lambert BS, Boutris N, McCulloch PC, Robbins AB, Moreno MR, et al. Validation of digital visual analog scale pain scoring with a traditional paper-based visual analog scale in adults. J Am Acad Orthop Surg Glob Res Rev. 2018;2(3):e088.PubMedPubMedCentral
9.
go back to reference Mansournia MA, Waters R, Nazemipour M, Bland M, Altman DG. Bland-Altman methods for comparing methods of measurement and response to criticisms. Glob Epidemiol. 2020;3:100045.CrossRefPubMedPubMedCentral Mansournia MA, Waters R, Nazemipour M, Bland M, Altman DG. Bland-Altman methods for comparing methods of measurement and response to criticisms. Glob Epidemiol. 2020;3:100045.CrossRefPubMedPubMedCentral
10.
go back to reference Westgard JO, Carey RN, Wold S. Criteria for judging precision and accuracy in method development and evaluation. Clin Chem. 1974;20:825–33.CrossRefPubMed Westgard JO, Carey RN, Wold S. Criteria for judging precision and accuracy in method development and evaluation. Clin Chem. 1974;20:825–33.CrossRefPubMed
11.
go back to reference Cimilli H, Karacaylı U, Şişman N, Kartal N, Mumcu G. Comparison of the oral health-related quality of life and dental pain in symptomatic irreversible pulpitis and pericoronitis. J Dent Sci. 2012;7:250–60.CrossRef Cimilli H, Karacaylı U, Şişman N, Kartal N, Mumcu G. Comparison of the oral health-related quality of life and dental pain in symptomatic irreversible pulpitis and pericoronitis. J Dent Sci. 2012;7:250–60.CrossRef
12.
go back to reference Ng YL, Mann V, Rahbaran S, Lewsey J, Gulabivala K. Outcome of primary root canal treatment: systematic review of the literature: part 2—influence of clinical factors. Int Endod J. 2008;41:6–31.CrossRefPubMed Ng YL, Mann V, Rahbaran S, Lewsey J, Gulabivala K. Outcome of primary root canal treatment: systematic review of the literature: part 2—influence of clinical factors. Int Endod J. 2008;41:6–31.CrossRefPubMed
13.
go back to reference Shanmugaraj M, Nivedha R, Mathan R, Balagopal S. Evaluation of working length determination methods: an in vivo / ex vivo study. Indian J Dent Res. 2007;18:60–2.CrossRefPubMed Shanmugaraj M, Nivedha R, Mathan R, Balagopal S. Evaluation of working length determination methods: an in vivo / ex vivo study. Indian J Dent Res. 2007;18:60–2.CrossRefPubMed
14.
go back to reference Kim E, Marmo M, Lee C-Y, Oh N-S, Kim I-K. An in vivo comparison of working length. determination by only. root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105:79–83. Kim E, Marmo M, Lee C-Y, Oh N-S, Kim I-K. An in vivo comparison of working length. determination by only. root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105:79–83.
15.
go back to reference Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length: a randomized clinical trial. J Endod. 2010;11:1753–6.CrossRef Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length: a randomized clinical trial. J Endod. 2010;11:1753–6.CrossRef
16.
go back to reference ElAyouti A, Dima E, Ohmer J, Sperl K, von Ohle C. Consistency of apex locator function: a clinical study. J Endod. 2009;35:179–81.CrossRefPubMed ElAyouti A, Dima E, Ohmer J, Sperl K, von Ohle C. Consistency of apex locator function: a clinical study. J Endod. 2009;35:179–81.CrossRefPubMed
17.
go back to reference Stinson JN, Kavanagh T, Yamada J, Gill N, Stevens B. Systematic review of the psychometric properties, interpretability and feasibility of self-report pain intensity measures for use in clinical trials in children and adolescents. Pain. 2006;125:143–57.CrossRefPubMed Stinson JN, Kavanagh T, Yamada J, Gill N, Stevens B. Systematic review of the psychometric properties, interpretability and feasibility of self-report pain intensity measures for use in clinical trials in children and adolescents. Pain. 2006;125:143–57.CrossRefPubMed
18.
go back to reference Arslan H, Güven Y, Karataş E, Doğanay E. Effect of the simultaneous working length control during root canal preparation on postoperative pain. J Endod. 2017;43(9):1422–7.CrossRefPubMed Arslan H, Güven Y, Karataş E, Doğanay E. Effect of the simultaneous working length control during root canal preparation on postoperative pain. J Endod. 2017;43(9):1422–7.CrossRefPubMed
19.
go back to reference Morgental RD, Vier-Pelisser FV, Luisi SB, Cogo DM, Kopper PMP. Preflaring effects on the accuracy of three electronic apex locators. Revista Odonto Ciencia. 2011;26:331–5.CrossRef Morgental RD, Vier-Pelisser FV, Luisi SB, Cogo DM, Kopper PMP. Preflaring effects on the accuracy of three electronic apex locators. Revista Odonto Ciencia. 2011;26:331–5.CrossRef
20.
go back to reference Jeger FB, Janner SF, Bornstein MM, Lussi A. Endodontic working length measurement with preexisting cone-beam computed tomography scanning: a prospective, controlled clinical study. J Endod. 2012;38(7):884–8.CrossRefPubMed Jeger FB, Janner SF, Bornstein MM, Lussi A. Endodontic working length measurement with preexisting cone-beam computed tomography scanning: a prospective, controlled clinical study. J Endod. 2012;38(7):884–8.CrossRefPubMed
21.
go back to reference Iqbal M, Kurtz E, Kohli M. Incidence and factors related to flare-ups in a graduate endodontic programme. Int Endod J. 2009;42:99–104.CrossRefPubMed Iqbal M, Kurtz E, Kohli M. Incidence and factors related to flare-ups in a graduate endodontic programme. Int Endod J. 2009;42:99–104.CrossRefPubMed
22.
go back to reference Siqueira JF, Barnett F. Interappointment pain: mechanisms, diagnosis, and treatment. Endod Top. 2004;7:93–109.CrossRef Siqueira JF, Barnett F. Interappointment pain: mechanisms, diagnosis, and treatment. Endod Top. 2004;7:93–109.CrossRef
23.
go back to reference Mancini M, Felici R, Conte G, Costantini M, Cianconi L. Accuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study. J Endod. 2011;37:684–7.CrossRefPubMed Mancini M, Felici R, Conte G, Costantini M, Cianconi L. Accuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study. J Endod. 2011;37:684–7.CrossRefPubMed
24.
go back to reference Saha B, Alam S, Lyngdoh D, Mishra SK. Comparative evaluation of digital radiography, electronic apex locator and simultaneous working length determination on postoperative pain after root canal treatment: a randomized clinical trial. Eur Oral Res. 2024;58(1):44–50.PubMedPubMedCentral Saha B, Alam S, Lyngdoh D, Mishra SK. Comparative evaluation of digital radiography, electronic apex locator and simultaneous working length determination on postoperative pain after root canal treatment: a randomized clinical trial. Eur Oral Res. 2024;58(1):44–50.PubMedPubMedCentral
25.
go back to reference Unsal Peker B, Erdem Hepşenoğlu Y, Ersahan S, Eyüboğlu TF. Accuracy of working length measurement by Raypex 6: electronic apex locator versus actual measurements under stereomicroscope. Balk J Dent Med. 2022;26:15–21.CrossRef Unsal Peker B, Erdem Hepşenoğlu Y, Ersahan S, Eyüboğlu TF. Accuracy of working length measurement by Raypex 6: electronic apex locator versus actual measurements under stereomicroscope. Balk J Dent Med. 2022;26:15–21.CrossRef
26.
go back to reference Dummer PM, McGinn JH, Rees DG. The position and topography of the apical canal constriction and apical foramen. Int Endod J. 1984;17:192–8.CrossRefPubMed Dummer PM, McGinn JH, Rees DG. The position and topography of the apical canal constriction and apical foramen. Int Endod J. 1984;17:192–8.CrossRefPubMed
27.
go back to reference ElAyouti A, Weiger R, Löst C. Frequency of overinstrumentation with an acceptable radiographic working length. J Endod. 2001;27:49–52.CrossRefPubMed ElAyouti A, Weiger R, Löst C. Frequency of overinstrumentation with an acceptable radiographic working length. J Endod. 2001;27:49–52.CrossRefPubMed
28.
go back to reference Sharma MC, Arora V. Determination of working length of root canal. Med J Armed Forces India. 2010;66(3):231–4.CrossRefPubMed Sharma MC, Arora V. Determination of working length of root canal. Med J Armed Forces India. 2010;66(3):231–4.CrossRefPubMed
29.
go back to reference Wolters WJ, Duncan HF, Tomson PL, Karim IE, McKenna G, Dorri M, et al. Minimally invasive endodontics: a new diagnostic system for assessing pulpitis and subsequent treatment needs. Int Endod J. 2017;50:825–9.CrossRefPubMed Wolters WJ, Duncan HF, Tomson PL, Karim IE, McKenna G, Dorri M, et al. Minimally invasive endodontics: a new diagnostic system for assessing pulpitis and subsequent treatment needs. Int Endod J. 2017;50:825–9.CrossRefPubMed
31.
go back to reference Fleming CH, Litaker MS, Alley LW, Eleazer PD. Comparison of classic endodontic techniques versus contemporary techniques on endodontic treatment success. J Endod. 2010;36:414–8.CrossRefPubMed Fleming CH, Litaker MS, Alley LW, Eleazer PD. Comparison of classic endodontic techniques versus contemporary techniques on endodontic treatment success. J Endod. 2010;36:414–8.CrossRefPubMed
Metadata
Title
Comparison of electronic apex locator and simultaneous working length detection methods with radiological method in terms of postoperative pain
Authors
Emine Guzel
Miray Uyan
Seyda Ersahan
Mustafa Gundogar
Fatih Ozcelik
Publication date
01-12-2024
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2024
Electronic ISSN: 1472-6831