Skip to main content
Top
Published in:

07-12-2024 | Original Article

Pseudoaneurysms of lower limb of orthopaedic traumatological origin: a literature review and our experience of 18 cases

Authors: Jayaramaraju Dheenadhayalan, Vasudeva Nagashree, Agraharam Devendra, S. P. Sivakumar, Hari Venkatramani, V. S. Sanjai Ramkumar, Shanmuganathan Rajasekaran

Published in: European Journal of Trauma and Emergency Surgery | Issue 6/2024

Login to get access

Abstract

Introduction and aims

Arterial pseudoaneurysm is a rare yet potentially life-threatening complication that can arise as a late sequelae of penetrating injuries or orthopaedic procedures. We aim at sharing our institutional experience of managing 18 cases of lower limb arterial pseudoaneurysms in orthopaedic practice and to provide technical tips for emergency management of severe bleeding. A comprehensive literature review resulting from fractures and orthopaedic surgeries is also presented.

Results

The study group consisted mainly of male patients with a mean age of 48.5 years. The mean duration between injury and pseudoaneurysm diagnosis was 86.7 days. CT angiography and USG Doppler were the main diagnostic modality. Among the cases, five resulted from fracture fragments and 13 from iatrogenic injuries. Surgical interventions varied based on the artery involved and included excision and ligation, bypass grafting with dacron or vein graft, primary repair, and amputation in two cases. Complications included one patient with blowout at the anastomotic site and another case of deep infection. The literature review encompassed 108 cases of pseudoaneurysm of lower limb associated with fractures and iatrogenic injuries during orthopaedic procedures. Clinical manifestations varied widely which included painful swelling, pulsatility, bleeding, and neurological deficits. CT angiography was the most utilized diagnostic modality, while therapeutic embolization was the most common treatment method.

Conclusion

Iatrogenic arterial injuries contributed to more than 60% of the cases as per the literature review. The most frequent mechanisms related to instrumentation were the placement of the third and fourth screws of the DHS plate, and the distal screw of a short nail in treating pertrochanteric fractures. This can be avoided by external rotation and abduction of the limb during distal screw insertion. A high index of clinical suspicion is needed especially when bleeding from the hardware site is noted. A swelling in the previously operated site should raise a suspicion of pseudoaneurysm and incision and drainage must be avoided without further imaging (Duplex USG or CT angiography). This study highlights the importance of cautious surgical techniques to minimize the occurrence of vascular injuries during orthopaedic surgeries.
Literature
1.
go back to reference Raherinantenaina F, Rajaonanahary TMA, Rakoto Ratsimba HN. Les faux anévrismes de l’artère fémorale en orthopédie et en traumatologie. J Mal Vasc. 2015;40(6):376–83.CrossRefPubMed Raherinantenaina F, Rajaonanahary TMA, Rakoto Ratsimba HN. Les faux anévrismes de l’artère fémorale en orthopédie et en traumatologie. J Mal Vasc. 2015;40(6):376–83.CrossRefPubMed
3.
go back to reference Kinoshita H, Hashimoto M, Hirayama J, Fujita K, Takeuchi Y, Iwasaki J, et al. Huge pseudoaneurysm of the femoral artery after internal fixation of femoral trochanteric fracture. Case Rep Orthop. 2018;25(2018):1–4. Kinoshita H, Hashimoto M, Hirayama J, Fujita K, Takeuchi Y, Iwasaki J, et al. Huge pseudoaneurysm of the femoral artery after internal fixation of femoral trochanteric fracture. Case Rep Orthop. 2018;25(2018):1–4.
4.
go back to reference Mahmoud SSS, Ahmed B, Hamid K, Milburn S, Baker P. Identification of the medial femoral safe zone for drilling during dynamic hip screw side plate fixation: a CT angiogram tracing of the profunda femoris artery. Injury. 2019;50(3):720–6.CrossRefPubMed Mahmoud SSS, Ahmed B, Hamid K, Milburn S, Baker P. Identification of the medial femoral safe zone for drilling during dynamic hip screw side plate fixation: a CT angiogram tracing of the profunda femoris artery. Injury. 2019;50(3):720–6.CrossRefPubMed
5.
go back to reference Biswas S, McNerney P, Kiproff P. Pseudoaneurysm of the profunda femoris artery following blunt trauma treated by endovascular coil embolization: review of two cases and relevant literature. Case Rep Emerg Med. 2017;2017:8079674.PubMedPubMedCentral Biswas S, McNerney P, Kiproff P. Pseudoaneurysm of the profunda femoris artery following blunt trauma treated by endovascular coil embolization: review of two cases and relevant literature. Case Rep Emerg Med. 2017;2017:8079674.PubMedPubMedCentral
6.
go back to reference Hamoui M, Larbi A, Bommart S, Fauré P, Largey A, Canovas F. False aneurysm of perforating branch of the profunda femoris artery following intertrochanteric fracture, a rare vascular complication: clinical, radiological features and management: Case report and review of the literature. Eur J Orthop Surg Traumatol. 2009;1(20):59–65. Hamoui M, Larbi A, Bommart S, Fauré P, Largey A, Canovas F. False aneurysm of perforating branch of the profunda femoris artery following intertrochanteric fracture, a rare vascular complication: clinical, radiological features and management: Case report and review of the literature. Eur J Orthop Surg Traumatol. 2009;1(20):59–65.
7.
go back to reference Lazarov M, Van Der Bracht H, Victor J, Stuyts B. Missed diagnosis of false aneurysm of the superficial femoral artery after closed complex fracture of the distal femur. Orthop Traumatol Surg Res. 2014;100(6):695–7.CrossRefPubMed Lazarov M, Van Der Bracht H, Victor J, Stuyts B. Missed diagnosis of false aneurysm of the superficial femoral artery after closed complex fracture of the distal femur. Orthop Traumatol Surg Res. 2014;100(6):695–7.CrossRefPubMed
9.
10.
go back to reference Dujon D, La Hausse-Brown TP, O’Hare P. Pseudo-aneurysm of the lateral circumflex humeral artery following external fixation of a free fibular transfer. Injury. 1995;26(8):551–2.CrossRefPubMed Dujon D, La Hausse-Brown TP, O’Hare P. Pseudo-aneurysm of the lateral circumflex humeral artery following external fixation of a free fibular transfer. Injury. 1995;26(8):551–2.CrossRefPubMed
11.
go back to reference Baldwin D, Mashbari H, Chow KL, Sarhan M. Ruptured superficial femoral artery anastomotic pseudoaneurysm after 30 years. Case Rep Vasc Med. 2019;22(2019): e1679214. Baldwin D, Mashbari H, Chow KL, Sarhan M. Ruptured superficial femoral artery anastomotic pseudoaneurysm after 30 years. Case Rep Vasc Med. 2019;22(2019): e1679214.
12.
go back to reference Raherinantenaina F, Rajaonanahary TMA, Rakoto Ratsimba HN. Management of traumatic arterial pseudoaneurysms as a result of limb trauma. Formos J Surg. 2016;49(3):89–100.CrossRef Raherinantenaina F, Rajaonanahary TMA, Rakoto Ratsimba HN. Management of traumatic arterial pseudoaneurysms as a result of limb trauma. Formos J Surg. 2016;49(3):89–100.CrossRef
13.
go back to reference Sajjad J, Coveney A, Ahmed A, Fulton G. An iatrogenic popliteal pseudoaneurysm masked under compartment syndrome of leg. J Surg Case Rep. 2014;11:rju116–rju116.CrossRef Sajjad J, Coveney A, Ahmed A, Fulton G. An iatrogenic popliteal pseudoaneurysm masked under compartment syndrome of leg. J Surg Case Rep. 2014;11:rju116–rju116.CrossRef
14.
go back to reference Polak WG, Pawlowski S, Skora J, Morasiewicz L, Janczak D, Oleszkiewicz M, et al. Gefäßkomplikationen nach der Behandlung mit dem Ilizarov-Ringfixateur. Vasa. 2001;30(2):138–40.CrossRefPubMed Polak WG, Pawlowski S, Skora J, Morasiewicz L, Janczak D, Oleszkiewicz M, et al. Gefäßkomplikationen nach der Behandlung mit dem Ilizarov-Ringfixateur. Vasa. 2001;30(2):138–40.CrossRefPubMed
15.
go back to reference Barquet A, Gelink A, Giannoudis PV. Proximal femoral fractures and vascular injuries in adults: incidence, aetiology and outcomes. Injury. 2015;46(12):2297–313.CrossRefPubMed Barquet A, Gelink A, Giannoudis PV. Proximal femoral fractures and vascular injuries in adults: incidence, aetiology and outcomes. Injury. 2015;46(12):2297–313.CrossRefPubMed
16.
go back to reference Rajaesparan K, Amin MA, Arora S, Walton NP. Pseudoaneurysm of a branch of the profunda femoris artery following distal locking of an intramedullary hip nail: an unusual anatomical location. Hip Int. 2008;18(3):231–5.CrossRefPubMed Rajaesparan K, Amin MA, Arora S, Walton NP. Pseudoaneurysm of a branch of the profunda femoris artery following distal locking of an intramedullary hip nail: an unusual anatomical location. Hip Int. 2008;18(3):231–5.CrossRefPubMed
17.
go back to reference Vande Voorde K, Dauwe J, Van Oost J. Late presentation of an iatrogenic pseudoaneurysm of the profunda femoris artery following intramedullary nailing. Case Rep Orthop. 2018;23(2018):1–5. Vande Voorde K, Dauwe J, Van Oost J. Late presentation of an iatrogenic pseudoaneurysm of the profunda femoris artery following intramedullary nailing. Case Rep Orthop. 2018;23(2018):1–5.
18.
go back to reference Ritchie ED, Haverkamp D, Schiphorst TJMJ, Bosscha K. False aneurysm of the profunda femoris artery, a rare complication of a proximal femoral fracture. Acta Orthop Belg. 2007;73(4):530–2.PubMed Ritchie ED, Haverkamp D, Schiphorst TJMJ, Bosscha K. False aneurysm of the profunda femoris artery, a rare complication of a proximal femoral fracture. Acta Orthop Belg. 2007;73(4):530–2.PubMed
19.
go back to reference Ryzewicz M, Robinson M, McConnell J, Lindeque B. Vascular injury during fixation of an intertrochanteric hip fracture in a patient with severe atherosclerosis. A case report. J Bone Joint Surg Am. 2006;88(11):2483–6.CrossRefPubMed Ryzewicz M, Robinson M, McConnell J, Lindeque B. Vascular injury during fixation of an intertrochanteric hip fracture in a patient with severe atherosclerosis. A case report. J Bone Joint Surg Am. 2006;88(11):2483–6.CrossRefPubMed
20.
go back to reference Laohapoonrungsee A, Sirirungruangsarn Y, Arpornchayanon O. Pseudoaneurysm of profunda femoris artery following internal fixation of intertrochanteric fracture: two cases report. J Med Assoc Thai. 2005;88(11):1703–6.PubMed Laohapoonrungsee A, Sirirungruangsarn Y, Arpornchayanon O. Pseudoaneurysm of profunda femoris artery following internal fixation of intertrochanteric fracture: two cases report. J Med Assoc Thai. 2005;88(11):1703–6.PubMed
21.
go back to reference Yang KH, Yoon CS, Park HW, Won JH, Park SJ. Position of the superficial femoral artery in closed hip nailing. Arch Orthop Trauma Surg. 2004;124(3):169–72.CrossRefPubMed Yang KH, Yoon CS, Park HW, Won JH, Park SJ. Position of the superficial femoral artery in closed hip nailing. Arch Orthop Trauma Surg. 2004;124(3):169–72.CrossRefPubMed
23.
go back to reference Agrawal P, Das S, Kumar N. Misery of orthopaedic surgeon: delayed diagnosis of pseudoaneurysm of profunda femoris artery following fixation of intertrochanteric femoral fracture: a case report and review of literature. J Orthop Case Rep. 2020;10(3):53–6.PubMedPubMedCentral Agrawal P, Das S, Kumar N. Misery of orthopaedic surgeon: delayed diagnosis of pseudoaneurysm of profunda femoris artery following fixation of intertrochanteric femoral fracture: a case report and review of literature. J Orthop Case Rep. 2020;10(3):53–6.PubMedPubMedCentral
24.
go back to reference Miller-Thomas MM, West OC, Cohen AM. Diagnosing traumatic arterial injury in the extremities with CT angiography: pearls and pitfalls. RadioGraphics. 2005;25(suppl_1):S133-42.CrossRefPubMed Miller-Thomas MM, West OC, Cohen AM. Diagnosing traumatic arterial injury in the extremities with CT angiography: pearls and pitfalls. RadioGraphics. 2005;25(suppl_1):S133-42.CrossRefPubMed
25.
go back to reference Altuwaijri T, Alsalman M, Altoijry A, Iqbal K, AlGhofili H. Ultrasound-guided thrombin injection versus ultrasound-guided compression repair in the treatment of post-catheterization femoral artery pseudoaneurysm: King Saud University Medical Center Experience. Turk Gogus Kalp Damar Cerrahisi Derg. 2020;28(1):114–9.CrossRefPubMedPubMedCentral Altuwaijri T, Alsalman M, Altoijry A, Iqbal K, AlGhofili H. Ultrasound-guided thrombin injection versus ultrasound-guided compression repair in the treatment of post-catheterization femoral artery pseudoaneurysm: King Saud University Medical Center Experience. Turk Gogus Kalp Damar Cerrahisi Derg. 2020;28(1):114–9.CrossRefPubMedPubMedCentral
26.
go back to reference Kang SS, Labropoulos N, Mansour MA, Baker WH. Percutaneous ultrasound guided thrombin injection: a new method for treating postcatheterization femoral pseudoaneurysms. J Vasc Surg. 1998;27(6):1032–8.CrossRefPubMed Kang SS, Labropoulos N, Mansour MA, Baker WH. Percutaneous ultrasound guided thrombin injection: a new method for treating postcatheterization femoral pseudoaneurysms. J Vasc Surg. 1998;27(6):1032–8.CrossRefPubMed
27.
go back to reference Mavrogenis AF, Rossi G, Rimondi E, Ruggieri P, Mercuri M. Embolisation for vascular injuries complicating elective orthopaedic surgery. Eur J Vasc Endovasc Surg. 2011;42(5):676–83.CrossRefPubMed Mavrogenis AF, Rossi G, Rimondi E, Ruggieri P, Mercuri M. Embolisation for vascular injuries complicating elective orthopaedic surgery. Eur J Vasc Endovasc Surg. 2011;42(5):676–83.CrossRefPubMed
28.
go back to reference Naouli H, Jiber H, Bouarhroum A. False aneurysm of perforating branch of the deep femoral artery—report of two cases. Int J Surg Case Rep. 2015;1(14):36–9.CrossRef Naouli H, Jiber H, Bouarhroum A. False aneurysm of perforating branch of the deep femoral artery—report of two cases. Int J Surg Case Rep. 2015;1(14):36–9.CrossRef
29.
go back to reference Pandey NN, Raju SN, Rajagopal R, Kumar S. Iatrogenic profunda femoris artery pseudoaneurysm: late presentation with successful endovascular microcoil embolisation. BMJ Case Rep. 2018;11(1): e228314.CrossRefPubMedPubMedCentral Pandey NN, Raju SN, Rajagopal R, Kumar S. Iatrogenic profunda femoris artery pseudoaneurysm: late presentation with successful endovascular microcoil embolisation. BMJ Case Rep. 2018;11(1): e228314.CrossRefPubMedPubMedCentral
30.
go back to reference Chan WSW, Kong SW, Sun KW, Tsang PK, Chow HL. Pseudoaneurysm and intramuscular haematoma after dynamic hip screw fixation for intertrochanteric femoral fracture: a case report. J Orthop Surg. 2010;18(2):244–7.CrossRef Chan WSW, Kong SW, Sun KW, Tsang PK, Chow HL. Pseudoaneurysm and intramuscular haematoma after dynamic hip screw fixation for intertrochanteric femoral fracture: a case report. J Orthop Surg. 2010;18(2):244–7.CrossRef
31.
go back to reference Iakovlev M, Marchand JB, Poirier P, Bargoin K, Gouëffic Y. Posttraumatic axillary false aneurysm after luxatio erecta of the shoulder: case report and literature review. Ann Vasc Surg. 2014;28(5):1321.e13-1321.e18.CrossRefPubMed Iakovlev M, Marchand JB, Poirier P, Bargoin K, Gouëffic Y. Posttraumatic axillary false aneurysm after luxatio erecta of the shoulder: case report and literature review. Ann Vasc Surg. 2014;28(5):1321.e13-1321.e18.CrossRefPubMed
32.
go back to reference Kragh JF Jr, Walters TJ, Baer DG, et al. Practical use of emergency tourniquets to stop bleeding in major limb trauma. J Trauma. 2008;64(2 Suppl):S38–50.PubMed Kragh JF Jr, Walters TJ, Baer DG, et al. Practical use of emergency tourniquets to stop bleeding in major limb trauma. J Trauma. 2008;64(2 Suppl):S38–50.PubMed
33.
go back to reference Navein J, Coupland R, Dunn R. The tourniquet controversy. J Trauma. 2003;54(5 Suppl):S219–20.PubMed Navein J, Coupland R, Dunn R. The tourniquet controversy. J Trauma. 2003;54(5 Suppl):S219–20.PubMed
34.
go back to reference Odinsson A, Finsen V. Tourniquet use and its complications in Norway. J Bone Joint Surg Br. 2006;88:1090–2.CrossRefPubMed Odinsson A, Finsen V. Tourniquet use and its complications in Norway. J Bone Joint Surg Br. 2006;88:1090–2.CrossRefPubMed
35.
go back to reference Wakai A, Wang JH, Winter DC, Street JT, O’Sullivan RG, Redmond HP. Tourniquet-induced systemic inflammatory response in extremity surgery. J Trauma. 2001;51:922–6.CrossRefPubMed Wakai A, Wang JH, Winter DC, Street JT, O’Sullivan RG, Redmond HP. Tourniquet-induced systemic inflammatory response in extremity surgery. J Trauma. 2001;51:922–6.CrossRefPubMed
36.
go back to reference Han CD, Lee YH, Yang KH, et al. Relationship between distal screws and femoral arteries in closed hip nailing on computed tomography angiography. Arch Orthop Trauma Surg. 2013;133(3):361–6.CrossRefPubMed Han CD, Lee YH, Yang KH, et al. Relationship between distal screws and femoral arteries in closed hip nailing on computed tomography angiography. Arch Orthop Trauma Surg. 2013;133(3):361–6.CrossRefPubMed
37.
go back to reference Hussain S, Balamoody S, Wright S, Bose D, Fenton P. Avoiding iatrogenic vascular injury in tibial external fixation with half pins. An in-vivo study based on CT angiography. J Clin Orthop Trauma. 2022;25:101777.CrossRefPubMedPubMedCentral Hussain S, Balamoody S, Wright S, Bose D, Fenton P. Avoiding iatrogenic vascular injury in tibial external fixation with half pins. An in-vivo study based on CT angiography. J Clin Orthop Trauma. 2022;25:101777.CrossRefPubMedPubMedCentral
38.
go back to reference Mavrogenis A, Panagopoulos G, Kokkalis Z, Koulouvaris P, Megaloikonomos P, Igoumenou V, et al. Vascular injury in orthopedic trauma. Orthopedics. 2016;17:39. Mavrogenis A, Panagopoulos G, Kokkalis Z, Koulouvaris P, Megaloikonomos P, Igoumenou V, et al. Vascular injury in orthopedic trauma. Orthopedics. 2016;17:39.
40.
go back to reference Varastehravan H, Nough H, Ansari Z. Management of iatrogenic rupture of profunda femoris artery after femoral fracture fixation with stent graft implantation. J Tehran Heart Cent. 2010 Winter;5(1):42–4. Varastehravan H, Nough H, Ansari Z. Management of iatrogenic rupture of profunda femoris artery after femoral fracture fixation with stent graft implantation. J Tehran Heart Cent. 2010 Winter;5(1):42–4.
Metadata
Title
Pseudoaneurysms of lower limb of orthopaedic traumatological origin: a literature review and our experience of 18 cases
Authors
Jayaramaraju Dheenadhayalan
Vasudeva Nagashree
Agraharam Devendra
S. P. Sivakumar
Hari Venkatramani
V. S. Sanjai Ramkumar
Shanmuganathan Rajasekaran
Publication date
07-12-2024
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Trauma and Emergency Surgery / Issue 6/2024
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI