Skip to main content
Top

16-05-2024 | Myopia | Cataract

A Brillouin microscopy analysis of the crystalline lenses of Chinese adults with myopia

Authors: Yong Ma, Jian Cao, Yanze Yu, Teruko Fukuyama, Yongle Bao, Xuan Ding, Lingling Niu, Xingtao Zhou, Jing Zhao

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology

Login to get access

Abstract

To evaluate lenticular biomechanical and geometric parameters in Chinese adults with myopia and identify relevant factors using Brillouin microscopy (BM) and Pentacam. The biomechanical and geometric properties of the ocular lenses of Chinese adults with myopia were quantified using BM. Anterior segment images were acquired using a Pentacam. Correlated factors including age, sex, spherical equivalent (SE), intraocular pressure (IOP), axial length (AL), white-to-white ratio (WTW), central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were analyzed. We studied 65 eyes from 65 participants (mean age, 25.23 ± 6.12 years). Width of Top Plateau (WTP), Width of Bottom Plateau (WBP), Slope of Anterior Cortex (SAC), Slope of Posterior Cortex (SPC), and Height of Plateau (Height) metrics obtained using BM showed mean values of 2.597 ± 0.393 mm, 4.310 ± 0.535 mm, 1.344 ± 0.549 GPa/mm, –1.343 ± 0.480 GPa/mm, and 3.373 ± 0.048 GPa, respectively. No significant correlation was found between these parameters and sex, SE, IOP, CCT, ACA, or Height. Interestingly, WBP (r = 0.467, P < 0.001), SAC (r = 0.412, P = 0.001), and SPC (r = –0.280, P = 0.024) were significantly associated with age, and an age-related increase of WBP (slope of 35.36 ± 10.08 μm per year) was identified. Both ACD and ACV showed significant correlations with SAC (r = 0.329 and 0.380, P = 0.008 and 0.002, respectively), but not with SPC. BM provided a novel perspective on lenticular biomechanical and geometric properties in Chinese adults with myopia, which correlated with age, AL, WTW, ACD, and ACV.
Literature
1.
go back to reference Wang K, Pierscionek BK (2019) Biomechanics of the human lens and accommodative system: Functional relevance to physiological states. Prog Retin Eye Res 71:114–131CrossRefPubMed Wang K, Pierscionek BK (2019) Biomechanics of the human lens and accommodative system: Functional relevance to physiological states. Prog Retin Eye Res 71:114–131CrossRefPubMed
2.
go back to reference Wei L, He W, Meng J, Qian D, Lu Y, Zhu X (2021) Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes. Invest Ophthalmol Vis Sci 62(1):7CrossRefPubMedPubMedCentral Wei L, He W, Meng J, Qian D, Lu Y, Zhu X (2021) Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes. Invest Ophthalmol Vis Sci 62(1):7CrossRefPubMedPubMedCentral
3.
go back to reference Coleman DJ, Fish SK (2001) Presbyopia, accommodation, and the mature catenary. Ophthalmology 108(9):1544–1551CrossRefPubMed Coleman DJ, Fish SK (2001) Presbyopia, accommodation, and the mature catenary. Ophthalmology 108(9):1544–1551CrossRefPubMed
4.
go back to reference Li Y, Zhu J, Chen JJ, Yu J, Jin Z, Miao Y, Browne AW, Zhou Q, Chen Z. Simultaneously imaging and quantifying in vivo mechanical properties of crystalline lens and cornea using optical coherence elastography with acoustic radiation force excitation. APL Photonics. 2019 Oct;4(10):106104 Li Y, Zhu J, Chen JJ, Yu J, Jin Z, Miao Y, Browne AW, Zhou Q, Chen Z. Simultaneously imaging and quantifying in vivo mechanical properties of crystalline lens and cornea using optical coherence elastography with acoustic radiation force excitation. APL Photonics. 2019 Oct;4(10):106104
5.
go back to reference Cheng C, Parreno J, Nowak RB, Biswas SK, Wang K, Hoshino M, Uesugi K, Yagi N, Moncaster JA, Lo WK et al (2019) Age-related changes in eye lens biomechanics, morphology, refractive index and transparency. Aging 11(24):12497–12531CrossRefPubMedPubMedCentral Cheng C, Parreno J, Nowak RB, Biswas SK, Wang K, Hoshino M, Uesugi K, Yagi N, Moncaster JA, Lo WK et al (2019) Age-related changes in eye lens biomechanics, morphology, refractive index and transparency. Aging 11(24):12497–12531CrossRefPubMedPubMedCentral
6.
go back to reference Hirasawa K, Nakakura S, Nakao Y, Fujino Y, Matsuura M, Murata H, Kiuchi Y, Asaoka R (2018) Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery. Am J Ophthalmol 195:26–35CrossRefPubMed Hirasawa K, Nakakura S, Nakao Y, Fujino Y, Matsuura M, Murata H, Kiuchi Y, Asaoka R (2018) Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery. Am J Ophthalmol 195:26–35CrossRefPubMed
8.
go back to reference Weeber HA, Eckert G, Soergel F, Meyer CH, Pechhold W, van der Heijde RG (2005) Dynamic mechanical properties of human lenses. Exp Eye Res 80(3):425–434CrossRefPubMed Weeber HA, Eckert G, Soergel F, Meyer CH, Pechhold W, van der Heijde RG (2005) Dynamic mechanical properties of human lenses. Exp Eye Res 80(3):425–434CrossRefPubMed
9.
go back to reference Besner S, Scarcelli G, Pineda R, Yun SH. In Vivo Brillouin Analysis of the Aging Crystalline Lens. Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5093-5100 Besner S, Scarcelli G, Pineda R, Yun SH. In Vivo Brillouin Analysis of the Aging Crystalline Lens. Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5093-5100
10.
go back to reference Meng J, Wei L, He W, Qi J, Lu Y, Zhu X. Lens thickness and associated ocular biometric factors among cataract patients in Shanghai. Eye Vis (Lond). 2021 May 31;8(1):22 Meng J, Wei L, He W, Qi J, Lu Y, Zhu X. Lens thickness and associated ocular biometric factors among cataract patients in Shanghai. Eye Vis (Lond). 2021 May 31;8(1):22
11.
go back to reference Henriquez MA, Mejías JA, Rincon M, Izquierdo L, Binder PS (2020) Correlation between lens thickness and lens density in patients with mild to moderate cataracts. Br J Ophthalmol 104(10):1350–1357CrossRefPubMed Henriquez MA, Mejías JA, Rincon M, Izquierdo L, Binder PS (2020) Correlation between lens thickness and lens density in patients with mild to moderate cataracts. Br J Ophthalmol 104(10):1350–1357CrossRefPubMed
12.
go back to reference Ye Y, Zhao J, Niu L, Shi W, Wang X, Zhou X (2022) Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old. Br J Ophthalmol 106(11):1508–1513CrossRefPubMed Ye Y, Zhao J, Niu L, Shi W, Wang X, Zhou X (2022) Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old. Br J Ophthalmol 106(11):1508–1513CrossRefPubMed
13.
go back to reference Vaughan JM, Randall JT (1980) Brillouin scattering, density and elastic properties of the lens and cornea of the eye. Nature 284(5755):489–491CrossRefPubMed Vaughan JM, Randall JT (1980) Brillouin scattering, density and elastic properties of the lens and cornea of the eye. Nature 284(5755):489–491CrossRefPubMed
14.
go back to reference Ambekar YS, Singh M, Scarcelli G, Rueda EM, Hall BM, Poché RA, Larin KV. Characterization of retinal biomechanical properties using Brillouin microscopy. J Biomed Opt. 2020 Sep;25(9):090502 Ambekar YS, Singh M, Scarcelli G, Rueda EM, Hall BM, Poché RA, Larin KV. Characterization of retinal biomechanical properties using Brillouin microscopy. J Biomed Opt. 2020 Sep;25(9):090502
15.
go back to reference Zhang H, Asroui L, Tarib I, Dupps WJ Jr, Scarcelli G, Randleman JB (2023) Motion-Tracking Brillouin Microscopy Evaluation of Normal, Keratoconic, and Post-Laser Vision Correction Corneas. Am J Ophthalmol 254:128–140CrossRefPubMed Zhang H, Asroui L, Tarib I, Dupps WJ Jr, Scarcelli G, Randleman JB (2023) Motion-Tracking Brillouin Microscopy Evaluation of Normal, Keratoconic, and Post-Laser Vision Correction Corneas. Am J Ophthalmol 254:128–140CrossRefPubMed
16.
go back to reference Shao P, Seiler TG, Eltony AM, Ramier A, Kwok SJJ, Scarcelli G, Ii RP, Yun SH (2018) Effects of Corneal Hydration on Brillouin Microscopy In Vivo. Invest Ophthalmol Vis Sci 59(7):3020–3027CrossRefPubMedPubMedCentral Shao P, Seiler TG, Eltony AM, Ramier A, Kwok SJJ, Scarcelli G, Ii RP, Yun SH (2018) Effects of Corneal Hydration on Brillouin Microscopy In Vivo. Invest Ophthalmol Vis Sci 59(7):3020–3027CrossRefPubMedPubMedCentral
19.
go back to reference Prevedel R, Diz-Muñoz A, Ruocco G, Antonacci G (2019) Brillouin microscopy: an emerging tool for mechanobiology. Nat Methods 16(10):969–977CrossRefPubMed Prevedel R, Diz-Muñoz A, Ruocco G, Antonacci G (2019) Brillouin microscopy: an emerging tool for mechanobiology. Nat Methods 16(10):969–977CrossRefPubMed
20.
go back to reference Ambekar YS, Singh M, Zhang J, Nair A, Aglyamov SR, Scarcelli G, Larin KV. Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. Biomed Opt Express. 2020 Mar 17;11(4):2041-2051 Ambekar YS, Singh M, Zhang J, Nair A, Aglyamov SR, Scarcelli G, Larin KV. Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. Biomed Opt Express. 2020 Mar 17;11(4):2041-2051
21.
go back to reference Scarcelli G, Kim P, Yun SH (2011) In vivo measurement of age-related stiffening in the crystalline lens by Brillouin optical microscopy. Biophys J 101(6):1539–1545CrossRefPubMedPubMedCentral Scarcelli G, Kim P, Yun SH (2011) In vivo measurement of age-related stiffening in the crystalline lens by Brillouin optical microscopy. Biophys J 101(6):1539–1545CrossRefPubMedPubMedCentral
23.
go back to reference Rosales P, Dubbelman M, Marcos S, van der Heijde R (2006) Crystalline lens radii of curvature from Purkinje and Scheimpflug imaging. J Vis 6(10):1057–1067CrossRefPubMed Rosales P, Dubbelman M, Marcos S, van der Heijde R (2006) Crystalline lens radii of curvature from Purkinje and Scheimpflug imaging. J Vis 6(10):1057–1067CrossRefPubMed
24.
go back to reference Xin X, Guo Q, Ming S, Liu C, Wang Z, Lei B (2021) High-Resolution Image Analysis Reveals a Decrease in Lens Thickness and Cone Density in a Cohort of Young Myopic Patients. Front Med 8:796778CrossRef Xin X, Guo Q, Ming S, Liu C, Wang Z, Lei B (2021) High-Resolution Image Analysis Reveals a Decrease in Lens Thickness and Cone Density in a Cohort of Young Myopic Patients. Front Med 8:796778CrossRef
26.
go back to reference Waring GOT, Chang DH, Rocha KM, Gouvea L, Penatti R (2021) Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age. Am J Pphthalmol 225:147–156CrossRef Waring GOT, Chang DH, Rocha KM, Gouvea L, Penatti R (2021) Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age. Am J Pphthalmol 225:147–156CrossRef
27.
go back to reference Muralidharan G, Martínez-Enríquez E, Birkenfeld J, Velasco-Ocana M, Pérez-Merino P, Marcos S (2019) Morphological changes of human crystalline lens in myopia. Biomed Opt Express 10(12):6084–6095CrossRefPubMedPubMedCentral Muralidharan G, Martínez-Enríquez E, Birkenfeld J, Velasco-Ocana M, Pérez-Merino P, Marcos S (2019) Morphological changes of human crystalline lens in myopia. Biomed Opt Express 10(12):6084–6095CrossRefPubMedPubMedCentral
28.
go back to reference Xie R, Zhou XT, Lu F, Chen M, Xue A, Chen S, Qu J (2009) Correlation between myopia and major biometric parameters of the eye: a retrospective clinical study. Optom Vision Sci : official Public Am Acad Optom 86(5):E503-508CrossRef Xie R, Zhou XT, Lu F, Chen M, Xue A, Chen S, Qu J (2009) Correlation between myopia and major biometric parameters of the eye: a retrospective clinical study. Optom Vision Sci : official Public Am Acad Optom 86(5):E503-508CrossRef
29.
go back to reference Nangia V, Jonas JB, Sinha A, Matin A, Kulkarni M (2010) Central corneal thickness and its association with ocular and general parameters in Indians: the Central India Eye and Medical Study. Ophthalmology 117(4):705–710CrossRefPubMed Nangia V, Jonas JB, Sinha A, Matin A, Kulkarni M (2010) Central corneal thickness and its association with ocular and general parameters in Indians: the Central India Eye and Medical Study. Ophthalmology 117(4):705–710CrossRefPubMed
30.
go back to reference Mohamed A, Nandyala S, Ho A, Manns F, Parel JA, Augusteyn RC (2021) Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age. Exp Eye Res 209:108653CrossRefPubMedPubMedCentral Mohamed A, Nandyala S, Ho A, Manns F, Parel JA, Augusteyn RC (2021) Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age. Exp Eye Res 209:108653CrossRefPubMedPubMedCentral
32.
go back to reference Augusteyn RC (2018) On the contribution of the nucleus and cortex to human lens shape and size. Clin Exp Optom 101(1):64–68CrossRefPubMed Augusteyn RC (2018) On the contribution of the nucleus and cortex to human lens shape and size. Clin Exp Optom 101(1):64–68CrossRefPubMed
33.
go back to reference Díez-Montero C (2023) López-de la Rosa A, López-Miguel A, Maldonado MJ: Relationship between the main components of the crystalline lens and the anterior chamber depth after cataract formation. Graefes Arch Clin Exp Ophthalmol 261(10):2853–2861CrossRefPubMedPubMedCentral Díez-Montero C (2023) López-de la Rosa A, López-Miguel A, Maldonado MJ: Relationship between the main components of the crystalline lens and the anterior chamber depth after cataract formation. Graefes Arch Clin Exp Ophthalmol 261(10):2853–2861CrossRefPubMedPubMedCentral
34.
go back to reference Jonas JB, Nangia V, Gupta R, Sinha A, Bhate K (2012) Lens thickness and associated factors. Clin Exp Ophthalmol 40(6):583–590CrossRefPubMed Jonas JB, Nangia V, Gupta R, Sinha A, Bhate K (2012) Lens thickness and associated factors. Clin Exp Ophthalmol 40(6):583–590CrossRefPubMed
35.
go back to reference Bolz M, Prinz A, Drexler W, Findl O (2007) Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes. Br J Ophthalmol 91(3):360–365CrossRefPubMed Bolz M, Prinz A, Drexler W, Findl O (2007) Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes. Br J Ophthalmol 91(3):360–365CrossRefPubMed
36.
go back to reference Xiang Y, Fu T, Xu Q, Chen W, Chen Z, Guo J, Deng C, Manyande A, Wang P, Zhang H et al (2021) Quantitative analysis of internal components of the human crystalline lens during accommodation in adults. Sci Rep 11(1):6688CrossRefPubMedPubMedCentral Xiang Y, Fu T, Xu Q, Chen W, Chen Z, Guo J, Deng C, Manyande A, Wang P, Zhang H et al (2021) Quantitative analysis of internal components of the human crystalline lens during accommodation in adults. Sci Rep 11(1):6688CrossRefPubMedPubMedCentral
37.
go back to reference Shammas HJ, Shammas MC (2015) Measuring the cataractous lens. J Cataract Refract Surg 41(9):1875–1879CrossRefPubMed Shammas HJ, Shammas MC (2015) Measuring the cataractous lens. J Cataract Refract Surg 41(9):1875–1879CrossRefPubMed
38.
go back to reference Catania F, Morenghi E, Rosetta P, Paolo V, Vinciguerra R (2023) Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature. Curr Eye Res 48(2):161–171CrossRefPubMed Catania F, Morenghi E, Rosetta P, Paolo V, Vinciguerra R (2023) Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature. Curr Eye Res 48(2):161–171CrossRefPubMed
39.
go back to reference Sun X, Dai Y, Chen Y, Yu DY, Cringle SJ, Chen J, Kong X, Wang X, Jiang C (2017) Primary angle closure glaucoma: What we know and what we don’t know. Prog Retin Eye Res 57:26–45CrossRefPubMed Sun X, Dai Y, Chen Y, Yu DY, Cringle SJ, Chen J, Kong X, Wang X, Jiang C (2017) Primary angle closure glaucoma: What we know and what we don’t know. Prog Retin Eye Res 57:26–45CrossRefPubMed
40.
go back to reference Patel HY, Danesh-Meyer HV (2013) Incidence and management of cataract after glaucoma surgery. Curr Opin Ophthalmol 24(1):15–20CrossRefPubMed Patel HY, Danesh-Meyer HV (2013) Incidence and management of cataract after glaucoma surgery. Curr Opin Ophthalmol 24(1):15–20CrossRefPubMed
Metadata
Title
A Brillouin microscopy analysis of the crystalline lenses of Chinese adults with myopia
Authors
Yong Ma
Jian Cao
Yanze Yu
Teruko Fukuyama
Yongle Bao
Xuan Ding
Lingling Niu
Xingtao Zhou
Jing Zhao
Publication date
16-05-2024
Publisher
Springer Berlin Heidelberg
Keyword
Myopia
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-024-06510-0