09-07-2022 | KNEE

Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty—an in vivo randomized controlled study of gait using dynamic radiostereometry

Authors: Emil Toft Petersen, Søren Rytter, Daan Koppens, Jesper Dalsgaard, Torben Bæk Hansen, Michael Skipper Andersen, Maiken Stilling

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 3/2023

Login to get access

Abstract

Purpose

New total knee arthroplasty implant designs attempt to normalize kinematics patterns that may improve functional performance and patient satisfaction. It was hypothesized that a more medial congruent (MC) anatomic bearing design (1) influences the tibiofemoral kinematics and (2) enhances articular congruency compared to a standard symmetrical cruciate retaining (CR) bearing design.

Methods

In this double-blinded randomized study, 66 patients with knee osteoarthritis were randomly included in two groups: MC (n = 31) and CR (n = 33). Clinical characteristics such as knee ligament lesions and knee osteoarthritis scores were graded on preoperative magnetic resonance imaging and radiography. At the 1-year follow-up, dynamic radiostereometric analysis was used to assess tibiofemoral joint kinematics and articulation congruency. Patient-reported outcome measures, Oxford Knee Score, the Forgotten Joint Score, and the Knee Osteoarthritis Outcome Score, were assessed preoperatively and at the 1-year follow-up.

Results

Compared to the CR bearing, the MC bearing displayed an offset with approximately 3 mm greater anterior tibial drawer (p < 0.001) during the entire motion, and up to approximately 3.5 degrees more tibial external rotation (p = 0.004) from mid-swing to the end of the gait cycle at the 1-year follow-up. Furthermore, the congruency area in the joint articulation was larger during approximately 80% of the gait cycle for the MC bearing compared to the CR. The patient-reported outcome measures improved (p < 0.001), but there were no differences between groups. In addition, there were no differences in clinical characteristics and there were no knee revisions or recognized deep infections during follow-up.

Conclusion

The study demonstrates that the MC-bearing design changes tibiofemoral kinematics and increases the area of congruency towards more native knee kinematics than the CR bearing. In perspective this may contribute to a more stabilized knee motion, restoring the patient’s confidence in knee function during daily activities.
Literature
1.
go back to reference Aalund PK, Larsen K, Hansen T, Bandholm T (2013) Normalized knee-extension strength or leg-press power after fast-track total knee arthroplasty: which measure is most closely associated with performance-based and self-reported function? Arch Phys Med Rehabil Arch Phys Med Rehabil 94:384–390PubMedCrossRef Aalund PK, Larsen K, Hansen T, Bandholm T (2013) Normalized knee-extension strength or leg-press power after fast-track total knee arthroplasty: which measure is most closely associated with performance-based and self-reported function? Arch Phys Med Rehabil Arch Phys Med Rehabil 94:384–390PubMedCrossRef
2.
go back to reference Behrend H, Giesinger K, Giesinger JM, Kuster MS (2012) The “Forgotten Joint” as the ultimate goal in joint arthroplasty. validation of a new patient-reported outcome measure. J Arthroplasty 27:430–436PubMedCrossRef Behrend H, Giesinger K, Giesinger JM, Kuster MS (2012) The “Forgotten Joint” as the ultimate goal in joint arthroplasty. validation of a new patient-reported outcome measure. J Arthroplasty 27:430–436PubMedCrossRef
3.
go back to reference Benedetti MG, Catani F, Bilotta TW, Marcacci M, Mariani E, Giannini S (2003) Muscle activation pattern and gait biomechanics after total knee replacement. Clin Biomech 18:871–876CrossRef Benedetti MG, Catani F, Bilotta TW, Marcacci M, Mariani E, Giannini S (2003) Muscle activation pattern and gait biomechanics after total knee replacement. Clin Biomech 18:871–876CrossRef
4.
go back to reference Bohannon RW, Williams Andrews A (2011) Normal walking speed: a descriptive meta-analysis. Physiotherapy 97:182–189PubMedCrossRef Bohannon RW, Williams Andrews A (2011) Normal walking speed: a descriptive meta-analysis. Physiotherapy 97:182–189PubMedCrossRef
5.
go back to reference Van Der Bom IMJ, Klein S, Staring M, Homan R, Bartels LW, Pluim JPW (2011) Evaluation of optimization methods for intensity-based 2D-3D registration in x-ray guided interventions. SPIE Med Imaging - Image Process, pp 657–671 Van Der Bom IMJ, Klein S, Staring M, Homan R, Bartels LW, Pluim JPW (2011) Evaluation of optimization methods for intensity-based 2D-3D registration in x-ray guided interventions. SPIE Med Imaging - Image Process, pp 657–671
6.
go back to reference Causero A, Di Benedetto P, Beltrame A, Gisonni R, Cainero V, Pagano M (2014) Design evolution in total knee replacement: which is the future? Acta Biomed 85:5–19PubMed Causero A, Di Benedetto P, Beltrame A, Gisonni R, Cainero V, Pagano M (2014) Design evolution in total knee replacement: which is the future? Acta Biomed 85:5–19PubMed
7.
go back to reference Christensen R, Petersen ET, Jürgens-Lahnstein J, Rytter S, Lindgren L, De Raedt S, Brüel A, Stilling M (2021) Assessment of knee kinematics with dynamic radiostereometry: validation of an automated model-based method of analysis using bone models. J Orthop Res 39:597–608PubMedCrossRef Christensen R, Petersen ET, Jürgens-Lahnstein J, Rytter S, Lindgren L, De Raedt S, Brüel A, Stilling M (2021) Assessment of knee kinematics with dynamic radiostereometry: validation of an automated model-based method of analysis using bone models. J Orthop Res 39:597–608PubMedCrossRef
8.
go back to reference Dabirrahmani D, Hogg M (2017) Modification of the grood and suntay joint coordinate system equations for knee joint flexion. Med Eng Phys 39:113–116PubMedCrossRef Dabirrahmani D, Hogg M (2017) Modification of the grood and suntay joint coordinate system equations for knee joint flexion. Med Eng Phys 39:113–116PubMedCrossRef
9.
go back to reference Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J bone Jt surgery [Br] 80:63–69CrossRef Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J bone Jt surgery [Br] 80:63–69CrossRef
10.
go back to reference Dennis DA, Komistek RD, Colwell CE, Ranawat CS, Scott RD, Thornhill TS, Lapp MA (1998) In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res 356:47–57CrossRef Dennis DA, Komistek RD, Colwell CE, Ranawat CS, Scott RD, Thornhill TS, Lapp MA (1998) In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res 356:47–57CrossRef
11.
go back to reference Dyrby CO, Andriacchi TP (2004) Secondary motions of the knee during weight bearing and non-weight bearing activities. J Orthop Res 22:794–800PubMedCrossRef Dyrby CO, Andriacchi TP (2004) Secondary motions of the knee during weight bearing and non-weight bearing activities. J Orthop Res 22:794–800PubMedCrossRef
12.
go back to reference Farrokhi S, Tashman S, Gil AB, Klatt BA, Fitzgerald GK (2012) Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study. Clin Biomech 27:384–389CrossRef Farrokhi S, Tashman S, Gil AB, Klatt BA, Fitzgerald GK (2012) Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study. Clin Biomech 27:384–389CrossRef
13.
go back to reference Fitch DA, Sedacki K, Yang Y (2014) Mid- to long-term outcomes of a medial-pivot system for primary total knee replacement: a systematic review and meta-analysis. Bone Joint Res Bone Joint Res 3:297–304PubMedCrossRef Fitch DA, Sedacki K, Yang Y (2014) Mid- to long-term outcomes of a medial-pivot system for primary total knee replacement: a systematic review and meta-analysis. Bone Joint Res Bone Joint Res 3:297–304PubMedCrossRef
14.
go back to reference Ghirardelli S, Asay JL, Leonardi EA, Amoroso T, Indelli PF, Andriacchi TP (2021) Kinematic comparison between medially congruent and posterior-stabilized third-generation tka designs. J Funct Morphol Kinesiol 6:27PubMedPubMedCentralCrossRef Ghirardelli S, Asay JL, Leonardi EA, Amoroso T, Indelli PF, Andriacchi TP (2021) Kinematic comparison between medially congruent and posterior-stabilized third-generation tka designs. J Funct Morphol Kinesiol 6:27PubMedPubMedCentralCrossRef
15.
go back to reference Gray HA, Guan S, Thomeer LT, Schache AG, de Steiger R, Pandy MG (2019) Three-dimensional motion of the knee-joint complex during normal walking revealed by mobile biplane x-ray imaging. J Orthop Res 37:615–630PubMedCrossRef Gray HA, Guan S, Thomeer LT, Schache AG, de Steiger R, Pandy MG (2019) Three-dimensional motion of the knee-joint complex during normal walking revealed by mobile biplane x-ray imaging. J Orthop Res 37:615–630PubMedCrossRef
16.
go back to reference Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef
17.
go back to reference Guan S, Gray HA, Schache AG, Feller J, de Steiger R, Pandy MG (2017) In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty. J Orthop Res 35:1634–1643PubMedCrossRef Guan S, Gray HA, Schache AG, Feller J, de Steiger R, Pandy MG (2017) In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty. J Orthop Res 35:1634–1643PubMedCrossRef
18.
go back to reference Hallén LG, Lindahl O (1966) The screw-home movement in the knee-joint. Acta Orthop 37:97–106CrossRef Hallén LG, Lindahl O (1966) The screw-home movement in the knee-joint. Acta Orthop 37:97–106CrossRef
19.
go back to reference Hansen L, De Raedt S, Jørgensen PB, Mygind-Klavsen B, Kaptein B, Stilling M (2018) Marker free model-based radiostereometric analysis for evaluation of hip joint kinematics. Bone Jt Res 7:379–387CrossRef Hansen L, De Raedt S, Jørgensen PB, Mygind-Klavsen B, Kaptein B, Stilling M (2018) Marker free model-based radiostereometric analysis for evaluation of hip joint kinematics. Bone Jt Res 7:379–387CrossRef
20.
go back to reference Hasegawa M, Naito Y, Yamaguchi T, Wakabayashi H, Sudo A (2018) Factors contributing to patient satisfaction and expectations following computer-assisted total knee arthroplasty. J Knee Surg 31:448–452PubMedCrossRef Hasegawa M, Naito Y, Yamaguchi T, Wakabayashi H, Sudo A (2018) Factors contributing to patient satisfaction and expectations following computer-assisted total knee arthroplasty. J Knee Surg 31:448–452PubMedCrossRef
21.
go back to reference Indelli PF, Morello F, Ghirardelli S, Fidanza A, Iannotti F, Ferrini A (2020) No clinical differences at the 2-year follow-up between single radius and J-curve medial pivot total knee arthroplasty in the treatment of neutral or varus knees. Knee Surgery, Sport Traumatol Arthrosc 28:3949–3954CrossRef Indelli PF, Morello F, Ghirardelli S, Fidanza A, Iannotti F, Ferrini A (2020) No clinical differences at the 2-year follow-up between single radius and J-curve medial pivot total knee arthroplasty in the treatment of neutral or varus knees. Knee Surgery, Sport Traumatol Arthrosc 28:3949–3954CrossRef
22.
go back to reference Indelli PF, Risitano S, Hall KE, Leonardi E, Migliore E (2019) Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes. Knee Surg Sport Traumatol Arthrosc 27:1028–1034CrossRef Indelli PF, Risitano S, Hall KE, Leonardi E, Migliore E (2019) Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes. Knee Surg Sport Traumatol Arthrosc 27:1028–1034CrossRef
23.
go back to reference Kang KT, Koh YG, Son J, Kwon OR, Park KK (2019) Flexed femoral component improves kinematics and biomechanical effect in posterior stabilized total knee arthroplasty. Knee Surg Sport Traumatol Arthrosc 27:1174–1181CrossRef Kang KT, Koh YG, Son J, Kwon OR, Park KK (2019) Flexed femoral component improves kinematics and biomechanical effect in posterior stabilized total knee arthroplasty. Knee Surg Sport Traumatol Arthrosc 27:1174–1181CrossRef
24.
go back to reference Kozanek M, Hosseini A, Liu F, Van de Velde SK, Gill TJ, Rubash HE, Li G (2009) Tibiofemoral kinematics and condylar motion during the stance phase of gait. J Biomech 42:1877–1884PubMedPubMedCentralCrossRef Kozanek M, Hosseini A, Liu F, Van de Velde SK, Gill TJ, Rubash HE, Li G (2009) Tibiofemoral kinematics and condylar motion during the stance phase of gait. J Biomech 42:1877–1884PubMedPubMedCentralCrossRef
25.
go back to reference Lafortune MA, Cavanagh PR, Sommer HJ, Kalenak A (1992) Three-dimensional kinematics of the human knee during walking. J Biomech 25:347–357PubMedCrossRef Lafortune MA, Cavanagh PR, Sommer HJ, Kalenak A (1992) Three-dimensional kinematics of the human knee during walking. J Biomech 25:347–357PubMedCrossRef
26.
go back to reference Lee JS, Hobden E, Stiell IG, Wells GA (2003) Clinically important change in the visual analog scale after adequate pain control. Acad Emerg Med 10:1128–1130PubMedCrossRef Lee JS, Hobden E, Stiell IG, Wells GA (2003) Clinically important change in the visual analog scale after adequate pain control. Acad Emerg Med 10:1128–1130PubMedCrossRef
27.
go back to reference Levine D, Richards J, MW W (2012) Whittle’s gait analysis. Churchill Livingstone (US) Levine D, Richards J, MW W (2012) Whittle’s gait analysis. Churchill Livingstone (US)
28.
go back to reference Lewek M, Rudolph K, Axe M, Snyder-Mackler L (2002) The effect of insufficient quadriceps strength on gait after anterior cruciate ligament reconstruction. Clin Biomech 17:56–63CrossRef Lewek M, Rudolph K, Axe M, Snyder-Mackler L (2002) The effect of insufficient quadriceps strength on gait after anterior cruciate ligament reconstruction. Clin Biomech 17:56–63CrossRef
29.
go back to reference Li JS, Tsai TY, Felson DT, Li G, Lewis CL (2017) Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait. PLoS One 12:1–11 Li JS, Tsai TY, Felson DT, Li G, Lewis CL (2017) Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait. PLoS One 12:1–11
30.
go back to reference Martin JW, Whiteside LA (1990) The influence of joint line position on knee stability after condylar knee arthroplasty. Clin Orthop Relat Res 259:146–156CrossRef Martin JW, Whiteside LA (1990) The influence of joint line position on knee stability after condylar knee arthroplasty. Clin Orthop Relat Res 259:146–156CrossRef
31.
go back to reference Masouros SD, Bull AMJ, Amis AA (2010) (i) Biomechanics of the knee joint. Orthop Trauma 24:84–91CrossRef Masouros SD, Bull AMJ, Amis AA (2010) (i) Biomechanics of the knee joint. Orthop Trauma 24:84–91CrossRef
32.
go back to reference Miura K, Ohkoshi Y, Ino T, Ukishiro K, Kawakami K, Suzuki S, Suzuki K, Maeda T (2020) Kinematics and center of axial rotation during walking after medial pivot type total knee arthroplasty. J Exp Orthop 7:72PubMedPubMedCentralCrossRef Miura K, Ohkoshi Y, Ino T, Ukishiro K, Kawakami K, Suzuki S, Suzuki K, Maeda T (2020) Kinematics and center of axial rotation during walking after medial pivot type total knee arthroplasty. J Exp Orthop 7:72PubMedPubMedCentralCrossRef
33.
go back to reference Mizner RL, Snyder-Mackler L (2005) Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty. J Orthop Res 23:1083–1090PubMedCrossRef Mizner RL, Snyder-Mackler L (2005) Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty. J Orthop Res 23:1083–1090PubMedCrossRef
34.
go back to reference Nichols TE, Holmes AP (2002) Nonparametric permutation tests for functional neuroimaging: a primer with examples. Hum Brain Mapp 15:1–25PubMedCrossRef Nichols TE, Holmes AP (2002) Nonparametric permutation tests for functional neuroimaging: a primer with examples. Hum Brain Mapp 15:1–25PubMedCrossRef
35.
go back to reference Nielsen ET, Stentz-Olesen K, de Raedt S, Jørgensen PB, Sørensen OG, Kaptein B, Andersen MS, Stilling M (2018) Influence of the anterolateral ligament on knee laxity: a biomechanical cadaveric study measuring knee kinematics in 6 degrees of freedom using dynamic radiostereometric analysis. Orthop J Sport Med 6:1–13CrossRef Nielsen ET, Stentz-Olesen K, de Raedt S, Jørgensen PB, Sørensen OG, Kaptein B, Andersen MS, Stilling M (2018) Influence of the anterolateral ligament on knee laxity: a biomechanical cadaveric study measuring knee kinematics in 6 degrees of freedom using dynamic radiostereometric analysis. Orthop J Sport Med 6:1–13CrossRef
36.
go back to reference O’Connor CM, Thorpe SK, O’Malley MJ, Vaughan CL (2007) Automatic detection of gait events using kinematic data. Gait Posture 25:469–474PubMedCrossRef O’Connor CM, Thorpe SK, O’Malley MJ, Vaughan CL (2007) Automatic detection of gait events using kinematic data. Gait Posture 25:469–474PubMedCrossRef
37.
go back to reference Pataky TC (2012) One-dimensional statistical parametric mapping in Python. Comput Methods Biomech Biomed Engin 15:295–301PubMedCrossRef Pataky TC (2012) One-dimensional statistical parametric mapping in Python. Comput Methods Biomech Biomed Engin 15:295–301PubMedCrossRef
38.
go back to reference Pataky TC, Robinson MA, Vanrenterghem J (2013) Vector field statistical analysis of kinematic and force trajectories. J Biomech 46:2394–2401PubMedCrossRef Pataky TC, Robinson MA, Vanrenterghem J (2013) Vector field statistical analysis of kinematic and force trajectories. J Biomech 46:2394–2401PubMedCrossRef
39.
go back to reference Peterfy CG, Schneider E, Nevitt M (2008) The osteoarthritis initiative: report on the design rationale for the magnetic resonance imaging protocol for the knee. Osteoarthr Cartil 16:1433–1441CrossRef Peterfy CG, Schneider E, Nevitt M (2008) The osteoarthritis initiative: report on the design rationale for the magnetic resonance imaging protocol for the knee. Osteoarthr Cartil 16:1433–1441CrossRef
40.
go back to reference Petersen ET, Rytter S, Koppens D, Dalsgaard J, Hansen TB, Larsen NE, Andersen MS, Stilling M (2022) Patients with knee osteoarthritis can be divided into subgroups based on tibiofemoral joint kinematics of gait—an exploratory and dynamic radiostereometric study. Osteoarthr Cartil 30:249–259CrossRef Petersen ET, Rytter S, Koppens D, Dalsgaard J, Hansen TB, Larsen NE, Andersen MS, Stilling M (2022) Patients with knee osteoarthritis can be divided into subgroups based on tibiofemoral joint kinematics of gait—an exploratory and dynamic radiostereometric study. Osteoarthr Cartil 30:249–259CrossRef
41.
go back to reference Petersen ET, Vind TD, Jürgens-Lahnstein JH, Christensen R, Raedt S, Brüel A, Rytter S, Andersen MS, Stilling M, Jürgens-Lahnstein JH, Christensen R, de Raedt S, Brüel A, Andersen MS, Stilling M (2022) Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic-based and a CT-based volumetric model. J Orthop Res. https://doi.org/10.1002/jor.25359CrossRefPubMed Petersen ET, Vind TD, Jürgens-Lahnstein JH, Christensen R, Raedt S, Brüel A, Rytter S, Andersen MS, Stilling M, Jürgens-Lahnstein JH, Christensen R, de Raedt S, Brüel A, Andersen MS, Stilling M (2022) Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic-based and a CT-based volumetric model. J Orthop Res. https://​doi.​org/​10.​1002/​jor.​25359CrossRefPubMed
42.
go back to reference Riley PO, Paolini G, Della Croce U, Paylo KW, Kerrigan DC (2007) A kinematic and kinetic comparison of overground and treadmill walking in healthy subjects. Gait Posture 26:17–24PubMedCrossRef Riley PO, Paolini G, Della Croce U, Paylo KW, Kerrigan DC (2007) A kinematic and kinetic comparison of overground and treadmill walking in healthy subjects. Gait Posture 26:17–24PubMedCrossRef
43.
go back to reference Roos EM, Roos HP, Lohmander LS, Ekdahl C, Beynnon BD (1998) Knee Injury and Osteoarthritis Outcome Score (KOOS)–development of a self-administered outcome measure. J Orthop Sports Phys Ther 28:88–96PubMedCrossRef Roos EM, Roos HP, Lohmander LS, Ekdahl C, Beynnon BD (1998) Knee Injury and Osteoarthritis Outcome Score (KOOS)–development of a self-administered outcome measure. J Orthop Sports Phys Ther 28:88–96PubMedCrossRef
44.
go back to reference Sabatini L, Risitano S, Parisi G, Tosto F, Indelli PF, Atzori F, Massè A (2018) Medial pivot in total knee arthroplasty: Literature review and our first experience. Clin Med Insights Arthritis Musculoskelet Disord 11:1–4CrossRef Sabatini L, Risitano S, Parisi G, Tosto F, Indelli PF, Atzori F, Massè A (2018) Medial pivot in total knee arthroplasty: Literature review and our first experience. Clin Med Insights Arthritis Musculoskelet Disord 11:1–4CrossRef
45.
go back to reference Tsubosaka M, Ishida K, Kodato K, Shibanuma N, Hayashi S, Kurosaka M, Kuroda R, Matsumoto T (2021) Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis. Knee Surg Sport Traumatol Arthrosc 29:467–473CrossRef Tsubosaka M, Ishida K, Kodato K, Shibanuma N, Hayashi S, Kurosaka M, Kuroda R, Matsumoto T (2021) Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis. Knee Surg Sport Traumatol Arthrosc 29:467–473CrossRef
46.
go back to reference Victor J, Bellemans J (2006) Physiologic kinematics as a concept for better flexion in TKA. Clin Orthop Relat Res 452:53–58PubMedCrossRef Victor J, Bellemans J (2006) Physiologic kinematics as a concept for better flexion in TKA. Clin Orthop Relat Res 452:53–58PubMedCrossRef
47.
go back to reference Zhang Q, Chen Z, Zhang J, Hu J, Peng Y, Fan X, Jin Z (2019) Insert conformity variation affects kinematics and wear performance of total knee replacements. Clin Biomech 65:19–25CrossRef Zhang Q, Chen Z, Zhang J, Hu J, Peng Y, Fan X, Jin Z (2019) Insert conformity variation affects kinematics and wear performance of total knee replacements. Clin Biomech 65:19–25CrossRef
Metadata
Title
Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty—an in vivo randomized controlled study of gait using dynamic radiostereometry
Authors
Emil Toft Petersen
Søren Rytter
Daan Koppens
Jesper Dalsgaard
Torben Bæk Hansen
Michael Skipper Andersen
Maiken Stilling
Publication date
09-07-2022
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 3/2023
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-022-07036-w