Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Major Papers
Signal Intensity of the Cerebrospinal Fluid after Intravenous Administration of Gadolinium-based Contrast Agents: Strong Contrast Enhancement around the Vein of Labbe
Toshio OhashiShinji NaganawaEriko OgawaToshio KatagiriKayao Kuno
Author information
JOURNAL OPEN ACCESS

2019 Volume 18 Issue 3 Pages 194-199

Details
Abstract

Purpose: Since the first report on the deposition of gadolinium in the brain parenchyma after repeated intravenous administrations of gadolinium-based contrast agent GBCA (IV-GBCA), the mechanisms of penetration and retention are still remaining a hot topic of discussion and a target of investigation. We routinely obtain endolymphatic hydrops (EH) images at 4 h after IV administration of a single dose (SD) of GBCA (IV-SD-GBCA) using heavily T2-weighted three-dimensional fluid-attenuated inversion recovery imaging (hT2W-3D-FLAIR). Occasionally, we have encountered cases, which indicate high-signal intensity (SI) in the cerebrospinal fluid (CSF) surrounding the vein of Labbe. The purpose of the present study was to investigate the degree of contrast enhancement of the CSF surrounding the vein of Labbe on hT2W-3D-FLAIR after IV-SD-GBCA in comparison with other CSF spaces.

Materials and Methods: In 25 patients with a suspicion of EH, a magnetic resonance cisternography (MRC) and an hT2W-3D-FLAIR were obtained at 4 h after IV-SD-GBCA. The perivascular space (PVS) in the basal ganglia, CSF spaces in the ambient cistern (CSF-Amb), the CSF surrounding the superficial middle cerebral vein (CSF-SMCV), and the CSF surrounding the vein of Labbe (CSF-VL) were segmented on MRC. The PVS and CSF regions were co-registered onto the hT2W-3D-FLAIR and the SI of the PVS and CSF spaces were measured. The SI ratio (SIR) of the post-contrast hT2W-3D-FLAIR to the pre-contrast hT2W-3D-FLAIR was measured. Significant differences were evaluated using Steel-Dwass’s test for multiple comparisons.

Results: The SIR of the CSF-VL was significantly higher than that of the PVS (P = 0.008), the CSF-Amb (P = 0.021), and the CSF-SMCV (P = 0.023).

Conclusion: The strong contrast enhancement of CSF space around the vein of Labbe was confirmed on hT2W-3D-FLAIR at 4 h after IV-GBCA compared to the PVS and the other CSF spaces.

Content from these authors
© 2019 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top