Abstract

The ability of a photosensitizer-containing cellulose acetate film to kill bacteria was evaluated. Substantial kills were achieved following irradiation of the film with white light for up to 24 hours. Applying a photosensitizer-containing coating to surfaces could reduce the environmental load of pathogens, thus helping to prevent infectious disease transmission.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Oleinick, NL, Evans, HH. The photobiology of photodynamic therapy: cellular targets and mechanisms. Radiat Res 1998;150:146156.CrossRefGoogle ScholarPubMed
2.Hsi, RA, Rosenthal, DI, Glatstein, E. Photodynamic therapy in the treatment of cancer: current state of the art. Drugs 1999;57:725734.CrossRefGoogle ScholarPubMed
3.Wainwright, M. Photodynamic antimicrobial chemotherapy (PACT). J Antimicrob Chemother 1998;42:1328.Google Scholar
4.Rutala, WA, Katz, EB, Sherertz, RJ, Sarubbi, FA, Environmental study of a methicillin-resistant Staphylococcus aureus epidemic in a burn unit. J Clin Microbiol 1983;18:683688.Google Scholar
5.Chartered Institute of Building Service Engineers. CIBSE Lighting Guide LG2: Hospitals and Health Care Buildings. London: Chartered Institute of Building Service Engineers; 1989.Google Scholar