New Approaches to Percutaneous Gastrostomy

Mariana O'Dowd1 , M. Fredrick Given1 , Michael J. Lee1 , 2
  • 1Department of Academic Radiology, Beaumont Hospital, Dublin 9 and Royal College of Surgeons in Ireland, St. Stephen's Green, Dublin 2, Ireland
  • 2Professor
Further Information

Publication History

Publication Date:
16 December 2004 (online)

ABSTRACT

Novel approaches to percutaneous gastrostomy have evolved because of catheter clogging and displacement, which is commonly seen with currently available gastrostomy catheters. Low-profile button gastrostomy catheters, designed to be inserted into mature tracts, have recently been inserted into fresh gastrostomy tracts. Catheter clogging rarely occurs with these low-profile devices. Catheter displacement remains a problem but new buttons can be inserted at the patient's bedside without the need for a return visit to the radiology department. A 90 to 100% success rate has been shown for placement of gastrostomy buttons. Pull-type endoscopic gastrostomy catheters can be placed radiologically using a standard puncture of the stomach and cannulation of the gastroesophageal junction. A guide wire is manipulated up the esophagus and out the mouth. The pull-type gastrostomy catheter is then attached and pulled down through the esophagus and out through the anterior abdominal wall. These catheters have very good retention devices and rarely become dislodged. Catheter clogging is also rarely seen, provided larger devices are used. Radiological placement of percutaneous endoscopic gastrostomy tubes has been termed the “hybrid method” and has been shown to be cheaper than endoscopic and other fluoroscopic methods of gastrostomy.

REFERENCES

  • 1 Gauderer M W, Ponsky J L, Izant Jr R J. Gastrostomy without laparotomy: a percutaneous endoscopic technique.  J Pediatr Surg. 1980;  15 872-875
  • 2 Deutsch L S, Kannegieter L, Vanson D T, Miller D P, Bandon J C. Simplified percutaneous gastrostomy.  Radiology. 1992;  184 181-183
  • 3 Hicks M E, Srratt R S, Picus D, Marx M V, Lang E V. Fluoroscopically guided percutaneous gastrostomy and gastroenterostomy: analysis of 158 consecutive cases.  AJR Am J Roentgenol. 1990;  154 725-728
  • 4 Ferguson D R, Harig J M, Kozarek R A, Kelsey P B, Picha G J. Placement of a feeding button (“one-step button”) as the initial procedure.  Am J Gastroenterol. 1993;  88 501-504
  • 5 Ruangtrakool R, Ong T H. Gastrostomy button: clinical appraisal.  J Med Assoc Thai. 2000;  83 839-849
  • 6 Ruangtrakool R, Ong T H. Comparison between mushroom-type and balloon-type gastrostomy buttons.  J Med Assoc Thai. 2000;  83 719-724
  • 7 Griffiths M. Single-stage percutaneous gastrostomy button insertion: a leap forward.  JPEN J Parenter Enteral Nutr. 1996;  20 237-239
  • 8 Lyon S M, Haslam P J, Duke D, McGrath F, Lee M J. De novo placement of button gastrostomy catheters in an adult population: experience in 53 patients.  J Vasc Interv Radiol. 2003;  14 1283-1289
  • 9 Borge M A, Vesely T M, Picus D. Gastrostomy button placement through percutaneous gastrostomy tracts created with fluoroscopic guidance: experience in 27 children.  J Vasc Interv Radiol. 1995;  6 179-183
  • 10 Foutch P G, Talbert G A, Gaines J A, Sanowski R A. The gastrostomy button: a prospective assessment of safety, success, and spectrum of use.  Gastrointest Endosc. 1989;  35 41-44
  • 11 Duszak Jr R. Percutaneous gastrostomy and jejunostomy. Available at: http://www.emedicine.com Accessed March 3 2003
  • 12 Funaki B, Peirce R, Lorenz J et al.. Comparison of balloon- and mushroom-retained large-bore gastrostomy catheters.  AJR Am J Roentgenol. 2001;  177 359-362
  • 13 McQuaid K R, Little T E. Two fatal complications related to gastrostomy button placement.  Gastrointest Endosc. 1992;  38 601-603
  • 14 Szymski G X, Albazzaz A N, Funaki B et al.. Radiologically guided placement of pull-type gastrostomy tubes.  Radiology. 1997;  205 669-673
  • 15 Cahill A M, Kaye R D, Fitz C R, Towbin R B. “Push-pull” gastrostomy: a new technique for percutaneous gastrostomy tube insertion in the neonate and young infant.  Pediatr Radiol. 2001;  31 550-554
  • 16 Clark J A, Pugash R A, Pantalone R R. Radiologic peroral gastrostomy.  J Vasc Interv Radiol. 1999;  10 927-932
  • 17 Laasch H U, Wilbraham L, Bullen K et al.. Gastrostomy insertion: comparing the options-PEG, RIG or PIG?.  Clin Radiol. 2003;  58 398-405

 Professor
M. J Lee

Radiology Department, Beaumont Hospital

Dublin 9, Ireland

Email: mlee@rcsi.ie

    >