Skip to main content
Top

Open Access 29-01-2025 | Knee Osteoarthritis | Research

Small changes of femoral torsion in varus or valgus distal femoral osteotomy using patient-specific instruments

Authors: Lukas Jud, Georgios Neopoulos, Sandro Hodel, Lazaros Vlachopoulos, Sandro F. Fucentese

Published in: International Orthopaedics

Login to get access

Abstract

Purpose

Hinge fractures show a relatively high incidence in varus and valgus distal femoral osteotomy (DFO) and can lead to delayed- or non-union. Another observed complication of a hinge fracture is an unintentional change of the postoperative femoral torsion of up to + 9.5° in conventionally performed DFO. We hypothesize that the change of femoral torsion in case of a hinge fracture is less pronounced when DFO is performed using patient-specific instruments (PSI) compared to the literature of conventionally performed DFO.

Methods

All patients who underwent varus or valgus DFO using PSI from January 2014 to September 2023 were included. Radiographs and computed tomography (CT) scans were used to screen for hinge fractures. Pre- and postoperative femoral torsion was measured in CT.

Results

Thirty-five medial closing-wedge DFO (MCW-DFO), 27 lateral closing-wedge DFO (LCW-DFO), and 27 lateral opening-wedge DFO (LOW-DFO) were included, resulting in a total of 89 included osteotomies. A total of 55 hinge fractures (61.8%) were observed. The femoral torsion changed significantly from 20.5° ± 7.7° to 15.5° ± 8.1° (p < 0.001) in LOW-DFO with a hinge fracture, whereas the other two techniques showed no significant change of femoral torsion.

Conclusion

The use of PSI in varus and valgus DFO showed only small changes of the postoperative femoral torsion, even in case of a hinge fracture. The change of femoral torsion was depending on the type of DFO and was only significant in LOW-DFO, however, not exceeding a mean change of 5°.
Literature
2.
go back to reference Kim YC, Yang JH, Kim HJ et al (2018) Distal femoral varus osteotomy for valgus arthritis of the knees: Systematic review of open versus closed wedge osteotomy. Knee Surg Relat Res 30:3–16CrossRefPubMedPubMedCentral Kim YC, Yang JH, Kim HJ et al (2018) Distal femoral varus osteotomy for valgus arthritis of the knees: Systematic review of open versus closed wedge osteotomy. Knee Surg Relat Res 30:3–16CrossRefPubMedPubMedCentral
15.
go back to reference Nakayama H, Kanto R, Onishi S et al (2021) Hinge fracture in lateral closed-wedge distal femoral osteotomy in knees undergoing double-level osteotomy: assessment of postoperative change in rotational alignment using CT evaluation. Knee Surgery, Sport Traumatol Arthrosc 29:3337–3345. https://doi.org/10.1007/s00167-020-06197-wCrossRef Nakayama H, Kanto R, Onishi S et al (2021) Hinge fracture in lateral closed-wedge distal femoral osteotomy in knees undergoing double-level osteotomy: assessment of postoperative change in rotational alignment using CT evaluation. Knee Surgery, Sport Traumatol Arthrosc 29:3337–3345. https://​doi.​org/​10.​1007/​s00167-020-06197-wCrossRef
18.
go back to reference Hinz M, Cotic M, Diermeier T et al (2023) Derotational distal femoral osteotomy for patients with recurrent patellar instability and increased femoral antetorsion improves knee function and adequately treats both torsional and valgus malalignment. Knee Surgery, Sport Traumatol Arthrosc 31:3091–3097. https://doi.org/10.1007/s00167-022-07150-9CrossRef Hinz M, Cotic M, Diermeier T et al (2023) Derotational distal femoral osteotomy for patients with recurrent patellar instability and increased femoral antetorsion improves knee function and adequately treats both torsional and valgus malalignment. Knee Surgery, Sport Traumatol Arthrosc 31:3091–3097. https://​doi.​org/​10.​1007/​s00167-022-07150-9CrossRef
23.
25.
go back to reference Waidelich HA, Strecker W, Schneider E (1992) Computertomographische Torsionswinkel- Und Langenmessung an Der Unteren Extremitat. Methodik, Normalwerte Und Strahlenbelastung. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Neuen Bildgeb Verfahren 157:245–251CrossRef Waidelich HA, Strecker W, Schneider E (1992) Computertomographische Torsionswinkel- Und Langenmessung an Der Unteren Extremitat. Methodik, Normalwerte Und Strahlenbelastung. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Neuen Bildgeb Verfahren 157:245–251CrossRef
Metadata
Title
Small changes of femoral torsion in varus or valgus distal femoral osteotomy using patient-specific instruments
Authors
Lukas Jud
Georgios Neopoulos
Sandro Hodel
Lazaros Vlachopoulos
Sandro F. Fucentese
Publication date
29-01-2025
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-025-06415-5