Abstract

Background

The use of portable navigation systems (PNS) in total hip arthroplasty (THA) has become increasingly prevalent, with second-generation PNS (sPNS) demonstrating superior accuracy in the lateral decubitus position compared to first-generation PNS. However, few studies have compared different types of sPNS. This study retrospectively compares the accuracy and clinical outcomes of two different types of sPNS instruments in patients undergoing THA.

Methods

A total of 158 eligible patients who underwent THA at a single institution between 2019 and 2022 were enrolled in the study, including 89 who used an accelerometer-based PNS with handheld infrared stereo cameras in the Naviswiss group (group N) and 69 who used an augmented reality (AR)-based PNS in the AR-Hip group (group A). Accuracy error, navigation error, clinical outcomes, and preparation time were compared between the two groups.

Results

Accuracy errors for Inclination were comparable between group N (3.5° ± 3.0°) and group A (3.5° ± 3.1°) (p = 0.92). Accuracy errors for anteversion were comparable between group N (4.1° ± 3.1°) and group A (4.5° ± 4.0°) (p = 0.57). The navigation errors for inclination (group N: 2.9° ± 2.7°, group A: 3.0° ± 3.2°) and anteversion (group N: 4.3° ± 3.5°, group A: 4.3° ± 4.1°) were comparable between the groups (p = 0.86 and 0.94, respectively). The preparation time was shorter in group A than in group N (p = 0.036). There were no significant differences in operative time (p = 0.255), intraoperative blood loss (p = 0.387), or complications (p = 0.248) between the two groups.

Conclusion

An Accelerometer-based PNS using handheld infrared stereo cameras and AR-based PNS provide similar accuracy during THA in the lateral decubitus position, with a mean error of 3°–4° for both inclination and anteversion, though the AR-based PNS required a shorter preparation time.
Literature
6.
go back to reference Kamenaga T, Hayashi S, Hashimoto S, Matsumoto T, Takayama K, Fujishiro T, Hiranaka T, Niikura T, Kuroda R (2019) Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position. J Orthop Surg (Hong Kong) 27(2):2309499019848871. https://doi.org/10.1177/2309499019848871CrossRefPubMed Kamenaga T, Hayashi S, Hashimoto S, Matsumoto T, Takayama K, Fujishiro T, Hiranaka T, Niikura T, Kuroda R (2019) Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position. J Orthop Surg (Hong Kong) 27(2):2309499019848871. https://​doi.​org/​10.​1177/​2309499019848871​CrossRefPubMed
11.
go back to reference Anjiki K, Kamenaga T, Hayashi S, Hashimoto S, Kuroda Y, Nakano N, Fujishiro T, Hiranaka T, Niikura T, Kuroda R, Matsumoto T (2022) Effectiveness of an accelerometer-based portable navigation for intraoperative adjustment of leg length discrepancy in total hip arthroplasty in the supine position. J Orthop Sci 27(1):169–175. https://doi.org/10.1016/j.jos.2020.11.003CrossRefPubMed Anjiki K, Kamenaga T, Hayashi S, Hashimoto S, Kuroda Y, Nakano N, Fujishiro T, Hiranaka T, Niikura T, Kuroda R, Matsumoto T (2022) Effectiveness of an accelerometer-based portable navigation for intraoperative adjustment of leg length discrepancy in total hip arthroplasty in the supine position. J Orthop Sci 27(1):169–175. https://​doi.​org/​10.​1016/​j.​jos.​2020.​11.​003CrossRefPubMed
16.
go back to reference Kiyohara M, Hamai S, Shiomoto K, Harada S, Harada T, Motomura G, Ikemura S, Fujii M, Kawahara S, Nakashima Y (2022) Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study. Int J Comput Assist Radiol Surg 17(6):1007–1015. https://doi.org/10.1007/s11548-022-02592-5CrossRefPubMed Kiyohara M, Hamai S, Shiomoto K, Harada S, Harada T, Motomura G, Ikemura S, Fujii M, Kawahara S, Nakashima Y (2022) Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study. Int J Comput Assist Radiol Surg 17(6):1007–1015. https://​doi.​org/​10.​1007/​s11548-022-02592-5CrossRefPubMed
23.
28.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220CrossRefPubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220CrossRefPubMed
Metadata
Title
Retrospective study comparing the accuracies of handheld infrared stereo camera and augmented reality-based navigation systems for total hip arthroplasty
Authors
Shinya Tanaka
Yasuhiko Takegami
Yusuke Osawa
Masanori Okamoto
Shiro Imagama
Publication date
05-05-2024
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 6/2024
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-024-05330-5