Super-resolution sodium MRI of human gliomas at 3T using physics-based generative artificial intelligence

Authors: Catalina Raymond, Jingwen Yao, Alfredo L. Lopez Kolkovsky, Thorsten Feiweier, Bryan Clifford, Heiko Meyer, Xiaodong Zhong, Fei Han, Nicholas S. Cho, Francesco Sanvito, Sonoko Oshima, Noriko Salamon, Linda M. Liau, Kunal S. Patel, Richard G. Everson, Timothy F. Cloughesy, Benjamin M. Ellingson

Published in: Journal of Neuro-Oncology

Login to get access

Abstract

Purpose

Sodium neuroimaging provides unique insights into the cellular and metabolic properties of brain tumors. However, at 3T, sodium neuroimaging MRI’s low signal-to-noise ratio (SNR) and resolution discourages routine clinical use. We evaluated the recently developed Anatomically constrained GAN using physics-based synthetic MRI artifacts” (ATHENA) for high-resolution sodium neuroimaging of brain tumors at 3T. We hypothesized the model would improve the image quality while preserving the inherent sodium information.

Methods

4,573 proton MRI scans from 1,390 suspected brain tumor patients were used for training. Sodium and proton MRI datasets from Twenty glioma patients were collected for validation. Twenty-four image-guided biopsies from seven patients were available for sodium-proton exchanger (NHE1) expression evaluation on immunohistochemistry. High-resolution synthetic sodium images were generated using the ATHENA model, then compared to native sodium MRI and NHE1 protein expression from image-guided biopsy samples.

Results

The ATHENA produced synthetic-sodium MR with significantly improved SNR (native SNR 18.20 ± 7.04; synthetic SNR 23.83 ± 9.33, P = 0.0079). The synthetic-sodium values were consistent with the native measurements (P = 0.2058), with a strong linear correlation within contrast-enhancing areas of the tumor (R2= 0.7565, P = 0.0005), T2-hyperintense (R2= 0.7325, P < 0.0001), and necrotic areas (R2= 0.7678, P < 0.0001). The synthetic-sodium MR and the relative NHE1 expression from image-guided biopsies were better correlated for the synthetic (ρ= 0.3269, P < 0.0001) than the native (ρ= 0.1732, P = 0.0276) with higher sodium signal in samples expressing elevated NHE1 (P < 0.0001).

Conclusion

ATHENA generates high-resolution synthetic-sodium MRI at 3T, enabling clinically attainable multinuclear imaging for brain tumors that retain the inherent information from the native sodium. The resulting synthetic sodium significantly correlates with tissue expression, potentially supporting its utility as a non-invasive marker of underlying sodium homeostasis in brain tumors.
Appendix
This content is only visible if you are logged in and have the appropriate permissions.
Literature
This content is only visible if you are logged in and have the appropriate permissions.
Metadata
Title
Super-resolution sodium MRI of human gliomas at 3T using physics-based generative artificial intelligence
Authors
Catalina Raymond
Jingwen Yao
Alfredo L. Lopez Kolkovsky
Thorsten Feiweier
Bryan Clifford
Heiko Meyer
Xiaodong Zhong
Fei Han
Nicholas S. Cho
Francesco Sanvito
Sonoko Oshima
Noriko Salamon
Linda M. Liau
Kunal S. Patel
Richard G. Everson
Timothy F. Cloughesy
Benjamin M. Ellingson
Publication date
03-06-2025
Publisher
Springer US
Published in
Journal of Neuro-Oncology
Print ISSN: 0167-594X
Electronic ISSN: 1573-7373
DOI
https://doi.org/10.1007/s11060-025-05094-x

EAN 2025

Unlock your free and exclusive access to the latest news and expert interviews from the European Academy of Neurology's annual congress.

Read more

How can your team use biomarkers to improve management of AD? (Link opens in a new window)

Our experts explore using biomarker tests and interpreting results, establishing a shared decision-making approach with patients and caregivers, and applying biomarker testing to guide treatment strategies.

This content is intended for healthcare professionals outside of the UK.

Supported by:
  • Lilly
Developed by: Springer Health+ IME
Register your interest