Open Access 01-12-2024 | Denture | Research

Occlusal parameters and wear of artificial teeth in complete dentures with lingualized versus bilateral balanced occlusion: a randomized clinical trial

Authors: Zhiqiang Wang, Yan Su, Jianmin Wang, Yang Liu, Wenzhong Xing

Published in: BMC Oral Health | Issue 1/2024

Login to get access

Abstract

Objective

This study aimed to assess the occlusal contact area (OCA), occlusal contact number (OCN), bite force, and artificial tooth wear in complete dentures with lingualized and bilateral balanced occlusion.

Methods

Edentulous participants who fulfilled the inclusion criteria were divided into the three groups as follows: group I, dentures with lingualized occlusion using interpenetrating polymer network artificial teeth; group II, dentures with lingualized occlusion using double cross-linked artificial teeth; and group III, dentures with bilateral balanced occlusion using anatomical micro-hybrid resin teeth. The silicone techniques were used to assess the OCA and OCN of the mandibular dentures and the Dental Prescale II was used to evaluate the bite force at the 2-week, 3-month, and 12-month follow-up visits. Occlusal contact analyzer software was used to assess the maxillary and mandibular posterior tooth wear at the 12-month follow-up visit. All data was analyzed using the SPSS software.

Results

The OCA of group III was significantly higher than that of groups I and II at the 2-week follow-up visit, whereas group I was considerably higher than groups II and III at the 3-month and 12-month follow-up visits. The OCN of the three groups exhibited significant differences at all three follow-up visits. Groups I and II had significantly lower bite force than Group III at the three follow-up visits. At the 12-month follow-up visit, groups I and II had significantly higher wear than Group III.

Conclusions

As the duration of use increases, the occlusal contact area of complete dentures increases, regardless of the occlusal schemes. The bite force of lingualized occlusion is typically lower than that of bilateral balanced occlusion. The wear locations of artificial teeth differ between the two types of occlusal schemes. (Retrospectively registered: The Chinese Clinical Trial Registry, No. ChiCTR2300073420(11/07/2023))
Appendix
Available only for authorised users
Literature
1.
go back to reference Limpuangthip N, Somkotra T, Arksornnukit M. Modified retention and stability criteria for complete denture wearers: a risk assessment tool for impaired masticatory ability and oral health-related quality of life. J Prosthet Dent. 2018;120(1):43–9.CrossRefPubMed Limpuangthip N, Somkotra T, Arksornnukit M. Modified retention and stability criteria for complete denture wearers: a risk assessment tool for impaired masticatory ability and oral health-related quality of life. J Prosthet Dent. 2018;120(1):43–9.CrossRefPubMed
2.
go back to reference Goldstein G, Kapadia Y, Campbell S. Complete denture occlusion: best evidence consensus statement. J Prosthodont. 2021;30(S1):72–7.CrossRefPubMed Goldstein G, Kapadia Y, Campbell S. Complete denture occlusion: best evidence consensus statement. J Prosthodont. 2021;30(S1):72–7.CrossRefPubMed
3.
go back to reference Lemos C, Verri FR, Gomes J, Júnior JS, Moraes S, Pellizzer EP. Bilateral balanced occlusion compared to other occlusal schemes in complete dentures: a systematic review. J Oral Rehabil. 2018;45(4):344–54.CrossRefPubMed Lemos C, Verri FR, Gomes J, Júnior JS, Moraes S, Pellizzer EP. Bilateral balanced occlusion compared to other occlusal schemes in complete dentures: a systematic review. J Oral Rehabil. 2018;45(4):344–54.CrossRefPubMed
4.
go back to reference Kawai Y, Ikeguchi N, Suzuki A, Kuwashima A, Sakamoto R, Matsumaru Y, Kimoto S, Iijima M, Feine JS. A double blind randomized clinical trial comparing lingualized and fully bilateral balanced posterior occlusion for conventional complete dentures. J Prosthodont Res. 2017;61(2):113–22.CrossRefPubMed Kawai Y, Ikeguchi N, Suzuki A, Kuwashima A, Sakamoto R, Matsumaru Y, Kimoto S, Iijima M, Feine JS. A double blind randomized clinical trial comparing lingualized and fully bilateral balanced posterior occlusion for conventional complete dentures. J Prosthodont Res. 2017;61(2):113–22.CrossRefPubMed
5.
go back to reference Matsumaru Y. Influence of mandibular residual ridge resorption on objective masticatory measures of lingualized and fully bilateral balanced denture articulation. J Prosthodont Res. 2010;54(3):112–8.CrossRefPubMed Matsumaru Y. Influence of mandibular residual ridge resorption on objective masticatory measures of lingualized and fully bilateral balanced denture articulation. J Prosthodont Res. 2010;54(3):112–8.CrossRefPubMed
6.
go back to reference Lee HS, Ko KH, Huh YH, Cho LR, Park CJ. Correlation between occlusal contact area at various levels of interocclusal thicknesses and masticatory performance. J Oral Rehabil. 2022;49(5):522–8.CrossRefPubMed Lee HS, Ko KH, Huh YH, Cho LR, Park CJ. Correlation between occlusal contact area at various levels of interocclusal thicknesses and masticatory performance. J Oral Rehabil. 2022;49(5):522–8.CrossRefPubMed
7.
go back to reference Terauchi R, Arai K, Tanaka M, Kawazoe T, Baba S. Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars. Springerplus. 2015;4:703.CrossRefPubMedPubMedCentral Terauchi R, Arai K, Tanaka M, Kawazoe T, Baba S. Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars. Springerplus. 2015;4:703.CrossRefPubMedPubMedCentral
8.
go back to reference Zhao Z, Wang Q, Li J, Zhou M, Tang K, Chen J, Wang F. Construction of a novel digital method for quantitative analysis of occlusal contact and force. BMC Oral Health. 2023;23(1):190.CrossRefPubMedPubMedCentral Zhao Z, Wang Q, Li J, Zhou M, Tang K, Chen J, Wang F. Construction of a novel digital method for quantitative analysis of occlusal contact and force. BMC Oral Health. 2023;23(1):190.CrossRefPubMedPubMedCentral
9.
go back to reference Imamura Y, Sato Y, Kitagawa N, Uchida K, Osawa T, Omori M, Okada Y. Influence of occlusal loading force on occlusal contacts in natural dentition. J Prosthodont Res. 2015;59(2):113–20.CrossRefPubMed Imamura Y, Sato Y, Kitagawa N, Uchida K, Osawa T, Omori M, Okada Y. Influence of occlusal loading force on occlusal contacts in natural dentition. J Prosthodont Res. 2015;59(2):113–20.CrossRefPubMed
10.
go back to reference Shiga H, Komino M, Uesugi H, Sano M, Yokoyama M, Nakajima K, Ishikawa A. Comparison of two dental prescale systems used for the measurement of occlusal force. Odontology. 2020;108(4):676–80.CrossRefPubMed Shiga H, Komino M, Uesugi H, Sano M, Yokoyama M, Nakajima K, Ishikawa A. Comparison of two dental prescale systems used for the measurement of occlusal force. Odontology. 2020;108(4):676–80.CrossRefPubMed
11.
go back to reference Horie T, Kanazawa M, Komagamine Y, Hama Y, Minakuchi S. Association between near occlusal contact areas and mixing ability. J Oral Rehabil. 2014;41(11):829–35.CrossRefPubMed Horie T, Kanazawa M, Komagamine Y, Hama Y, Minakuchi S. Association between near occlusal contact areas and mixing ability. J Oral Rehabil. 2014;41(11):829–35.CrossRefPubMed
12.
go back to reference Stober T, Henninger M, Schmitter M, Pritsch M, Rammelsberg P. Three-body wear of resin denture teeth with and without nanofillers. J Prosthet Dent. 2010;103(2):108–17.CrossRefPubMed Stober T, Henninger M, Schmitter M, Pritsch M, Rammelsberg P. Three-body wear of resin denture teeth with and without nanofillers. J Prosthet Dent. 2010;103(2):108–17.CrossRefPubMed
13.
go back to reference Gad MM, Alalawi H, Akhtar S, Al-Ghamdi R, Alghamdi R, Al-Jefri A, Al-Qarni FD. Strength and wear behavior of three-dimensional printed and prefabricated denture teeth: an in vitro comparative analysis. Eur J Dent. 2023;17(4):1248–56.CrossRefPubMedPubMedCentral Gad MM, Alalawi H, Akhtar S, Al-Ghamdi R, Alghamdi R, Al-Jefri A, Al-Qarni FD. Strength and wear behavior of three-dimensional printed and prefabricated denture teeth: an in vitro comparative analysis. Eur J Dent. 2023;17(4):1248–56.CrossRefPubMedPubMedCentral
14.
go back to reference Saadi ASA, El-Damanhoury HM, Khalifa N. 2D and 3D wear analysis of 3D printed and prefabricated artificial teeth. Int Dent J. 2023;73(1):87–92.CrossRefPubMed Saadi ASA, El-Damanhoury HM, Khalifa N. 2D and 3D wear analysis of 3D printed and prefabricated artificial teeth. Int Dent J. 2023;73(1):87–92.CrossRefPubMed
15.
16.
go back to reference Heintze SD, Zellweger G, Grunert I, Munoz-Viveros CA, Hagenbuch K. Laboratory methods for evaluating the wear of denture teeth and their correlation with clinical results. Dent Mater. 2012;28(3):261–72.CrossRefPubMed Heintze SD, Zellweger G, Grunert I, Munoz-Viveros CA, Hagenbuch K. Laboratory methods for evaluating the wear of denture teeth and their correlation with clinical results. Dent Mater. 2012;28(3):261–72.CrossRefPubMed
17.
go back to reference Stober T, Geiger A, Rues S, Dreyhaupt J, Rammelsberg P, Ohlmann B. Factors affecting wear of composite resin denture teeth–24-month results from a clinical study. Clin Oral Investig. 2012;16(2):413–20.CrossRefPubMed Stober T, Geiger A, Rues S, Dreyhaupt J, Rammelsberg P, Ohlmann B. Factors affecting wear of composite resin denture teeth–24-month results from a clinical study. Clin Oral Investig. 2012;16(2):413–20.CrossRefPubMed
18.
go back to reference Heintze SD, Rousson V, Stober T. Patient- and therapy-related factors on the wear of denture teeth–results of a clinical trial. Dent Mater. 2015;31(3):302–7.CrossRefPubMed Heintze SD, Rousson V, Stober T. Patient- and therapy-related factors on the wear of denture teeth–results of a clinical trial. Dent Mater. 2015;31(3):302–7.CrossRefPubMed
19.
go back to reference Pham DM, Gonzalez MD, Ontiveros JC, Kasper FK, Frey GN, Belles DM. Wear resistance of 3D printed and prefabricated denture teeth opposing zirconia. J Prosthodont. 2021;30(9):804–10.CrossRefPubMed Pham DM, Gonzalez MD, Ontiveros JC, Kasper FK, Frey GN, Belles DM. Wear resistance of 3D printed and prefabricated denture teeth opposing zirconia. J Prosthodont. 2021;30(9):804–10.CrossRefPubMed
20.
go back to reference Heintze SD, Zellweger G, Sbicego S, Rousson V, Munoz-Viveros C, Stober T. Wear of two denture teeth materials in vivo-2-year results. Dent Mater. 2013;29(9):e191–204.CrossRefPubMed Heintze SD, Zellweger G, Sbicego S, Rousson V, Munoz-Viveros C, Stober T. Wear of two denture teeth materials in vivo-2-year results. Dent Mater. 2013;29(9):e191–204.CrossRefPubMed
21.
go back to reference Schmid-Schwap M, Rousson V, Vornwagner K, Heintze SD. Wear of two artificial tooth materials in vivo: a 12-month pilot study. J Prosthet Dent. 2009;102(2):104–14.CrossRefPubMed Schmid-Schwap M, Rousson V, Vornwagner K, Heintze SD. Wear of two artificial tooth materials in vivo: a 12-month pilot study. J Prosthet Dent. 2009;102(2):104–14.CrossRefPubMed
22.
go back to reference Zhang P, Xu J. Study on retention and stability of linear occlusal complete dentures. Zhonghua Kou Qiang Yi Xue Za Zhi. 2003;38(1):46–8.PubMed Zhang P, Xu J. Study on retention and stability of linear occlusal complete dentures. Zhonghua Kou Qiang Yi Xue Za Zhi. 2003;38(1):46–8.PubMed
23.
go back to reference Limpuangthip N, Tumrasvin W, Pinyowattanasilp T, Kulpiyavaja P. Evaluation of dynamic impression lining material effects on masticatory function and the oral health-related quality of life of complete denture wearers: a six-month randomized controlled trial. J Prosthodont Res. 2023;67(2):214–21.CrossRefPubMed Limpuangthip N, Tumrasvin W, Pinyowattanasilp T, Kulpiyavaja P. Evaluation of dynamic impression lining material effects on masticatory function and the oral health-related quality of life of complete denture wearers: a six-month randomized controlled trial. J Prosthodont Res. 2023;67(2):214–21.CrossRefPubMed
24.
go back to reference Xia Y, Ma C, Chen J, Witter DJ, Zhang Q, Creugers NHJ. Mandibular residual ridge morphology in relation to complete dentures and implant overdentures-part I: predictors for perceived conventional denture stability. Clin Implant Dent Relat Res. 2021;23(1):131–9.CrossRefPubMed Xia Y, Ma C, Chen J, Witter DJ, Zhang Q, Creugers NHJ. Mandibular residual ridge morphology in relation to complete dentures and implant overdentures-part I: predictors for perceived conventional denture stability. Clin Implant Dent Relat Res. 2021;23(1):131–9.CrossRefPubMed
25.
go back to reference Kühne C, Lohbauer U, Raith S, Reich S. Measurement of tooth wear by means of digital impressions: an in-vitro evaluation of three intraoral scanning systems. Appl Sci. 2021;11(11):5161.CrossRef Kühne C, Lohbauer U, Raith S, Reich S. Measurement of tooth wear by means of digital impressions: an in-vitro evaluation of three intraoral scanning systems. Appl Sci. 2021;11(11):5161.CrossRef
26.
go back to reference Korda B, Amlang A, Hugger A, Behrendt C, Ruge S. Number and localization of occlusal contact areas on natural posterior teeth without dental findings - evaluations of the regional baseline study (SHIP-1) with the Greifswald Digital Analyzing System (GEDAS). Int J Comput Dent. 2022;25(1):47–56. Korda B, Amlang A, Hugger A, Behrendt C, Ruge S. Number and localization of occlusal contact areas on natural posterior teeth without dental findings - evaluations of the regional baseline study (SHIP-1) with the Greifswald Digital Analyzing System (GEDAS). Int J Comput Dent. 2022;25(1):47–56.
27.
go back to reference Owens S, Buschang PH, Throckmorton GS, Palmer L, English J. Masticatory performance and areas of occlusal contact and near contact in subjects with normal occlusion and malocclusion. Am J Orthod Dentofac Orthop. 2002;121(6):602–9.CrossRef Owens S, Buschang PH, Throckmorton GS, Palmer L, English J. Masticatory performance and areas of occlusal contact and near contact in subjects with normal occlusion and malocclusion. Am J Orthod Dentofac Orthop. 2002;121(6):602–9.CrossRef
28.
go back to reference Lepley CR, Throckmorton GS, Ceen RF, Buschang PH. Relative contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance. Am J Orthod Dentofac Orthop. 2011;139(5):606–13.CrossRef Lepley CR, Throckmorton GS, Ceen RF, Buschang PH. Relative contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance. Am J Orthod Dentofac Orthop. 2011;139(5):606–13.CrossRef
29.
go back to reference Hidaka O, Iwasaki M, Saito M, Morimoto T. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure. J Dent Res. 1999;78(7):1336–44.CrossRefPubMed Hidaka O, Iwasaki M, Saito M, Morimoto T. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure. J Dent Res. 1999;78(7):1336–44.CrossRefPubMed
30.
go back to reference Engelmeier RL, Phoenix RD. The development of lingualized occlusion. J Prosthodont. 2019;28(1):e118–31.CrossRefPubMed Engelmeier RL, Phoenix RD. The development of lingualized occlusion. J Prosthodont. 2019;28(1):e118–31.CrossRefPubMed
31.
go back to reference Iwase M, Ohashi M, Tachibana H, Toyoshima T, Nagumo M. Bite force, occlusal contact area and masticatory efficiency before and after orthognathic surgical correction of mandibular prognathism. Int J Oral Maxillofac Surg. 2006;35(12):1102–7.CrossRefPubMed Iwase M, Ohashi M, Tachibana H, Toyoshima T, Nagumo M. Bite force, occlusal contact area and masticatory efficiency before and after orthognathic surgical correction of mandibular prognathism. Int J Oral Maxillofac Surg. 2006;35(12):1102–7.CrossRefPubMed
32.
go back to reference Shala K, Tmava-Dragusha A, Dula L, Pustina-Krasniqi T, Bicaj T, Ahmedi E, Lila Z. Evaluation of maximum bite force in patients with complete dentures. Open Access Maced J Med Sci. 2018;6(3):559–63.CrossRefPubMedPubMedCentral Shala K, Tmava-Dragusha A, Dula L, Pustina-Krasniqi T, Bicaj T, Ahmedi E, Lila Z. Evaluation of maximum bite force in patients with complete dentures. Open Access Maced J Med Sci. 2018;6(3):559–63.CrossRefPubMedPubMedCentral
33.
go back to reference Sonego MV, Goiato MC, Dos Santos DM. Electromyography evaluation of masseter and temporalis, bite force, and quality of life in elderly patients during the adaptation of mandibular implant-supported overdentures. Clin Oral Implants Res. 2017;28(10):e169–74.CrossRefPubMed Sonego MV, Goiato MC, Dos Santos DM. Electromyography evaluation of masseter and temporalis, bite force, and quality of life in elderly patients during the adaptation of mandibular implant-supported overdentures. Clin Oral Implants Res. 2017;28(10):e169–74.CrossRefPubMed
34.
go back to reference Morokuma M, Yoneyama Y, Matsuda R, Hosoi T, Ohkubo C. Influence of occlusal force on electroencephalograms in edentulous patients. J Prosthodont. 2015;24(7):532–7.CrossRefPubMed Morokuma M, Yoneyama Y, Matsuda R, Hosoi T, Ohkubo C. Influence of occlusal force on electroencephalograms in edentulous patients. J Prosthodont. 2015;24(7):532–7.CrossRefPubMed
35.
go back to reference Patil SR, Maragathavalli G, Sghaireen MG, Al-Zoubi IA, Vargheese S, Alam MK. Maximum bite force in complete denture wearing patients: a preliminary study. Int Med Journal: IMJ. 2019;26(3):220–2. Patil SR, Maragathavalli G, Sghaireen MG, Al-Zoubi IA, Vargheese S, Alam MK. Maximum bite force in complete denture wearing patients: a preliminary study. Int Med Journal: IMJ. 2019;26(3):220–2.
36.
go back to reference Thongudomporn U, Chongsuvivatwong V, Geater AF. The effect of maximum bite force on alveolar bone morphology. Orthod Craniofac Res. 2009;12(1):1–8.CrossRefPubMed Thongudomporn U, Chongsuvivatwong V, Geater AF. The effect of maximum bite force on alveolar bone morphology. Orthod Craniofac Res. 2009;12(1):1–8.CrossRefPubMed
38.
go back to reference Deniz DA, Kulak Ozkan Y. The influence of occlusion on masticatory performance and satisfaction in complete denture wearers. J Oral Rehabil. 2013;40(2):91–8.CrossRefPubMed Deniz DA, Kulak Ozkan Y. The influence of occlusion on masticatory performance and satisfaction in complete denture wearers. J Oral Rehabil. 2013;40(2):91–8.CrossRefPubMed
39.
go back to reference Kamonwanon P, Yodmongkol S, Chantarachindawong R, Thaweeboon S, Thaweeboon B, Srikhirin T. Wear resistance of a modified polymethyl methacrylate artificial tooth compared to five commercially available artificial tooth materials. J Prosthet Dent. 2015;114(2):286–92.CrossRefPubMed Kamonwanon P, Yodmongkol S, Chantarachindawong R, Thaweeboon S, Thaweeboon B, Srikhirin T. Wear resistance of a modified polymethyl methacrylate artificial tooth compared to five commercially available artificial tooth materials. J Prosthet Dent. 2015;114(2):286–92.CrossRefPubMed
40.
go back to reference Zeng J, Sato Y, Ohkubo C, Hosoi T. In vitro wear resistance of three types of composite resin denture teeth. J Prosthet Dent. 2005;94(5):453–7.CrossRefPubMed Zeng J, Sato Y, Ohkubo C, Hosoi T. In vitro wear resistance of three types of composite resin denture teeth. J Prosthet Dent. 2005;94(5):453–7.CrossRefPubMed
Metadata
Title
Occlusal parameters and wear of artificial teeth in complete dentures with lingualized versus bilateral balanced occlusion: a randomized clinical trial
Authors
Zhiqiang Wang
Yan Su
Jianmin Wang
Yang Liu
Wenzhong Xing
Publication date
01-12-2024
Publisher
BioMed Central
Keywords
Denture
Silicone
Published in
BMC Oral Health / Issue 1/2024
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-024-05144-2