Skip to main content
Top

13-11-2024 | Crohn's Disease

Improved Diagnostic Performance Using Dual-Energy CT-Derived Slope Parameter Images in Crohn’s Disease

Authors: Min Hong, Ziying Lin, Hua Zhong, Yan Zhang, Dan Yang, Sihui Zhong, Xiangrong Zhuang, Xin Yue

Published in: Journal of Imaging Informatics in Medicine

Login to get access

Abstract

The objective of the study is to explore the image quality and diagnosis performance of the dual-energy CT-derived slope parameter images (SPI) generated by the algorithm based on the slope function in the diagnosis of Crohn’s disease (CD). Seventy-six CD patients and 53 disease-free control group subjects who underwent dual-energy CT enterography were retrospectively collected. Portal venous phase 120kVp-like and virtual monoenergetic images at 40–100 keV (VMI40-100) were reconstructed. SPIs corresponding to the spectral curve between 40 and 100 keV (SPI40-100) were generated using Python. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of normal and abnormal intestinal walls were calculated. Image quality, noise, and contrast were independently scored by two radiologists using a 5-point scale. Four radiologists conducted CD diagnosis with three reading models (120kVp-like, 120kVp-like with optimal VMI, and 120kVp-like with SPI40-100). The diagnostic performances of the three reading models for diagnosing CD were evaluated using receiver operating characteristic (ROC) curves. The CNR in SPI40-100 was higher than in the other images (P < 0.05). The subjective evaluation showed that there was no statistical difference between the contrast of SPI40-100 and VMI40 (P > 0.05), but that of the two images was higher than the other images (P < 0.05). The scoring on the overall image quality of VMI50 was superior to that of other images (P < 0.05). The combined model of 120kVp-like with SPI40-100 had the strongest confidence (cases with high confidence: 36, 58, 49, 47 for radiologists 1, 2, 3, 4) and the highest efficiency in diagnosing CD (areas under the ROC curve: 0.973, 0.977, 0.982, 0.991 for radiologists 1, 2, 3, 4). SPI40-100 generated by the algorithm based on the slope function exhibited good image quality. The combined model of 120kVp-like with SPI40-100 could improve radiologists’ diagnostic efficiency and confidence in diagnosing CD.
Literature
1.
go back to reference Roda G, Chien Ng S, Kotze PG, Argollo M, Panaccione R, Spinelli A, et al. Crohn’s disease. Nat Rev Dis Primers. 2020;6(1):22.CrossRefPubMed Roda G, Chien Ng S, Kotze PG, Argollo M, Panaccione R, Spinelli A, et al. Crohn’s disease. Nat Rev Dis Primers. 2020;6(1):22.CrossRefPubMed
2.
go back to reference Nikolaus S, Schreiber S. Diagnostics of inflammatory bowel disease. Gastroenterology. 2007;133(5):1670-89.CrossRefPubMed Nikolaus S, Schreiber S. Diagnostics of inflammatory bowel disease. Gastroenterology. 2007;133(5):1670-89.CrossRefPubMed
3.
go back to reference Faubion WA, Jr., Fletcher JG, O’Byrne S, Feagan BG, de Villiers WJ, Salzberg B, et al. EMerging BiomARKers in Inflammatory Bowel Disease (EMBARK) study identifies fecal calprotectin, serum MMP9, and serum IL-22 as a novel combination of biomarkers for Crohn’s disease activity: role of cross-sectional imaging. Am J Gastroenterol. 2013;108(12):1891-900.CrossRefPubMed Faubion WA, Jr., Fletcher JG, O’Byrne S, Feagan BG, de Villiers WJ, Salzberg B, et al. EMerging BiomARKers in Inflammatory Bowel Disease (EMBARK) study identifies fecal calprotectin, serum MMP9, and serum IL-22 as a novel combination of biomarkers for Crohn’s disease activity: role of cross-sectional imaging. Am J Gastroenterol. 2013;108(12):1891-900.CrossRefPubMed
4.
go back to reference Sands BE, Ooi CJ. A survey of methodological variation in the Crohn’s disease activity index. Inflamm Bowel Dis. 2005;11(2):133-8.CrossRefPubMed Sands BE, Ooi CJ. A survey of methodological variation in the Crohn’s disease activity index. Inflamm Bowel Dis. 2005;11(2):133-8.CrossRefPubMed
5.
go back to reference Xuehua Li SF, Li Huang, Jie Zhou, Zhiyang Zhou, Siyun Huang, Ren Mao, Yao He, Wei Liu, Huadan Xue, Xuesong Zhao, Fuhua Yan, Liping Deng, Minhu Chen, Ziping Li. Expert guideline on imaging examination and report specification of inflammatory bowel disease in China. Chinese Journal of Inflammatory Bowel Diseases. 2021;05(01):E002-E. Xuehua Li SF, Li Huang, Jie Zhou, Zhiyang Zhou, Siyun Huang, Ren Mao, Yao He, Wei Liu, Huadan Xue, Xuesong Zhao, Fuhua Yan, Liping Deng, Minhu Chen, Ziping Li. Expert guideline on imaging examination and report specification of inflammatory bowel disease in China. Chinese Journal of Inflammatory Bowel Diseases. 2021;05(01):E002-E.
6.
go back to reference Taguchi N, Oda S, Kobayashi T, Naoe H, Sasaki Y, Imuta M, et al. Advanced parametric imaging for evaluation of Crohn’s disease using dual-energy computed tomography enterography. Radiol Case Rep. 2018;13(3):709-12.CrossRefPubMedPubMedCentral Taguchi N, Oda S, Kobayashi T, Naoe H, Sasaki Y, Imuta M, et al. Advanced parametric imaging for evaluation of Crohn’s disease using dual-energy computed tomography enterography. Radiol Case Rep. 2018;13(3):709-12.CrossRefPubMedPubMedCentral
7.
go back to reference Masselli G, Di Tola M, Casciani E, Polettini E, Laghi F, Monti R, et al. Diagnosis of Small-Bowel Diseases: Prospective Comparison of Multi-Detector Row CT Enterography with MR Enterography. Radiology. 2016;279(2):420-31.CrossRefPubMed Masselli G, Di Tola M, Casciani E, Polettini E, Laghi F, Monti R, et al. Diagnosis of Small-Bowel Diseases: Prospective Comparison of Multi-Detector Row CT Enterography with MR Enterography. Radiology. 2016;279(2):420-31.CrossRefPubMed
8.
go back to reference Macari M, Balthazar EJ. CT of bowel wall thickening: significance and pitfalls of interpretation. AJR Am J Roentgenol. 2001;176(5):1105-16.CrossRefPubMed Macari M, Balthazar EJ. CT of bowel wall thickening: significance and pitfalls of interpretation. AJR Am J Roentgenol. 2001;176(5):1105-16.CrossRefPubMed
9.
go back to reference Akbas A, Bakir H, Dasiran MF, Dagmura H, Daldal E, Ozsoy Z, et al. Colonic Wall Thickening Reported in Abdominal CT: Does It Always Imply Malignancy? Gastroenterol Res Pract. 2019;2019:2492097.CrossRefPubMedPubMedCentral Akbas A, Bakir H, Dasiran MF, Dagmura H, Daldal E, Ozsoy Z, et al. Colonic Wall Thickening Reported in Abdominal CT: Does It Always Imply Malignancy? Gastroenterol Res Pract. 2019;2019:2492097.CrossRefPubMedPubMedCentral
10.
go back to reference Bodily KD, Fletcher JG, Solem CA, Johnson CD, Fidler JL, Barlow JM, et al. Crohn Disease: mural attenuation and thickness at contrast-enhanced CT Enterography--correlation with endoscopic and histologic findings of inflammation. Radiology. 2006;238(2):505-16.CrossRefPubMed Bodily KD, Fletcher JG, Solem CA, Johnson CD, Fidler JL, Barlow JM, et al. Crohn Disease: mural attenuation and thickness at contrast-enhanced CT Enterography--correlation with endoscopic and histologic findings of inflammation. Radiology. 2006;238(2):505-16.CrossRefPubMed
11.
go back to reference Sakurai T, Katsuno T, Saito K, Yoshihama S, Nakagawa T, Koseki H, et al. Mesenteric findings of CT enterography are well correlated with the endoscopic severity of Crohn’s disease. Eur J Radiol. 2017;89:242-8.CrossRefPubMed Sakurai T, Katsuno T, Saito K, Yoshihama S, Nakagawa T, Koseki H, et al. Mesenteric findings of CT enterography are well correlated with the endoscopic severity of Crohn’s disease. Eur J Radiol. 2017;89:242-8.CrossRefPubMed
12.
go back to reference Kim YS, Kim SH, Ryu HS, Han JK. Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn’s Disease Activity Index and External Validation. Korean J Radiol. 2018;19(6):1077-88.CrossRefPubMedPubMedCentral Kim YS, Kim SH, Ryu HS, Han JK. Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn’s Disease Activity Index and External Validation. Korean J Radiol. 2018;19(6):1077-88.CrossRefPubMedPubMedCentral
13.
go back to reference Silva AC, Morse BG, Hara AK, Paden RG, Hongo N, Pavlicek W. Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics. 2011;31(4):1031–46; discussion 47–50. Silva AC, Morse BG, Hara AK, Paden RG, Hongo N, Pavlicek W. Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics. 2011;31(4):1031–46; discussion 47–50.
14.
go back to reference Furukawa A, Saotome T, Yamasaki M, Maeda K, Nitta N, Takahashi M, et al. Cross-sectional imaging in Crohn disease. Radiographics. 2004;24(3):689-702.CrossRefPubMed Furukawa A, Saotome T, Yamasaki M, Maeda K, Nitta N, Takahashi M, et al. Cross-sectional imaging in Crohn disease. Radiographics. 2004;24(3):689-702.CrossRefPubMed
15.
go back to reference Chinese Society of Radiology CAoR, Anhui Imaging Clinical Medical Research Center. China expert consensus on clinical application of multi-energy CT. Chinese Journal of Radiology. 2022;56:476–87. Chinese Society of Radiology CAoR, Anhui Imaging Clinical Medical Research Center. China expert consensus on clinical application of multi-energy CT. Chinese Journal of Radiology. 2022;56:476–87.
16.
go back to reference Dane B, Duenas S, Han J, O’Donnell T, Ream J, Chang S, et al. Crohn’s Disease Activity Quantified by Iodine Density Obtained From Dual-Energy Computed Tomography Enterography. J Comput Assist Tomogr. 2020;44(2):242-7.CrossRefPubMed Dane B, Duenas S, Han J, O’Donnell T, Ream J, Chang S, et al. Crohn’s Disease Activity Quantified by Iodine Density Obtained From Dual-Energy Computed Tomography Enterography. J Comput Assist Tomogr. 2020;44(2):242-7.CrossRefPubMed
17.
go back to reference Peng JC, Feng Q, Zhu J, Shen J, Qiao YQ, Xu JR, et al. Usefulness of spectral computed tomography for evaluation of intestinal activity and severity in ileocolonic Crohn’s disease. Therap Adv Gastroenterol. 2016;9(6):795-805.CrossRefPubMedPubMedCentral Peng JC, Feng Q, Zhu J, Shen J, Qiao YQ, Xu JR, et al. Usefulness of spectral computed tomography for evaluation of intestinal activity and severity in ileocolonic Crohn’s disease. Therap Adv Gastroenterol. 2016;9(6):795-805.CrossRefPubMedPubMedCentral
18.
go back to reference Liang X, Xue C, Huang X, Wei J, Zhou J. Value of energy spectrum CT parameters in the differential diagnosis of high-grade clear cell renal cell carcinoma and type II papillary renal cell carcinoma. Acta Radiol. 2022;63(4):545-52.CrossRefPubMed Liang X, Xue C, Huang X, Wei J, Zhou J. Value of energy spectrum CT parameters in the differential diagnosis of high-grade clear cell renal cell carcinoma and type II papillary renal cell carcinoma. Acta Radiol. 2022;63(4):545-52.CrossRefPubMed
19.
go back to reference Chen WB, Shi QQ, Li ZM, Li ZY, Kang LQ. Diagnostic value of spiral CT energy spectrum imaging in lymph node metastasis of colorectal cancer. Int J Colorectal Dis. 2022;37(9):2021-9.CrossRefPubMed Chen WB, Shi QQ, Li ZM, Li ZY, Kang LQ. Diagnostic value of spiral CT energy spectrum imaging in lymph node metastasis of colorectal cancer. Int J Colorectal Dis. 2022;37(9):2021-9.CrossRefPubMed
20.
go back to reference Zhang G, Cao Y, Zhang J, Zhao Z, Zhang W, Zhou J. Epidermal growth factor receptor mutations in lung adenocarcinoma: associations between dual-energy spectral CT measurements and histologic results. J Cancer Res Clin Oncol. 2021;147(4):1169-78.CrossRefPubMed Zhang G, Cao Y, Zhang J, Zhao Z, Zhang W, Zhou J. Epidermal growth factor receptor mutations in lung adenocarcinoma: associations between dual-energy spectral CT measurements and histologic results. J Cancer Res Clin Oncol. 2021;147(4):1169-78.CrossRefPubMed
21.
go back to reference Hua Zhong SD, inventorA Method for generating slope parametric images based on enhanced energy Spectral CT. China2022. Hua Zhong SD, inventorA Method for generating slope parametric images based on enhanced energy Spectral CT. China2022.
22.
go back to reference Chinese Medical Association Society of Gastroenterology Inflammatory Bowel Disease Group CIBDDaTQCEC. Chinese clinical practice guideline on the management of Crohn′s disease (2023, Guangzhou). Chinese Journal of Inflammatory Bowel Diseases. 2024;08(1):2–32. Chinese Medical Association Society of Gastroenterology Inflammatory Bowel Disease Group CIBDDaTQCEC. Chinese clinical practice guideline on the management of Crohn′s disease (2023, Guangzhou). Chinese Journal of Inflammatory Bowel Diseases. 2024;08(1):2–32.
23.
go back to reference Yaniv Z, Lowekamp BC, Johnson HJ, Beare R. SimpleITK Image-Analysis Notebooks: a Collaborative Environment for Education and Reproducible Research. J Digit Imaging. 2018;31(3):290-303.CrossRefPubMed Yaniv Z, Lowekamp BC, Johnson HJ, Beare R. SimpleITK Image-Analysis Notebooks: a Collaborative Environment for Education and Reproducible Research. J Digit Imaging. 2018;31(3):290-303.CrossRefPubMed
24.
go back to reference Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage. 2006;31(3):1116-28.CrossRefPubMed Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage. 2006;31(3):1116-28.CrossRefPubMed
25.
go back to reference Chen J, Zhou J, Yang J, Cong R, Sun J, Xiao J, et al. Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn’s disease. BMC Med Imaging. 2021;21(1):185.CrossRefPubMedPubMedCentral Chen J, Zhou J, Yang J, Cong R, Sun J, Xiao J, et al. Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn’s disease. BMC Med Imaging. 2021;21(1):185.CrossRefPubMedPubMedCentral
26.
go back to reference Ploussi A, Alexopoulou E, Economopoulos N, Argentos SI, Tsitsia V, Arapakis I, et al. Patient radiation exposure and image quality evaluation with the use of iDose4 iterative reconstruction algorithm in chest-abdomen-pelvis CT examinations. Radiat Prot Dosimetry. 2014;158(4):399-405.CrossRefPubMed Ploussi A, Alexopoulou E, Economopoulos N, Argentos SI, Tsitsia V, Arapakis I, et al. Patient radiation exposure and image quality evaluation with the use of iDose4 iterative reconstruction algorithm in chest-abdomen-pelvis CT examinations. Radiat Prot Dosimetry. 2014;158(4):399-405.CrossRefPubMed
27.
go back to reference Lee SM, Kim SH, Ahn SJ, Kang HJ, Kang JH, Han JK. Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease. Eur Radiol. 2018;28(6):2525-34.CrossRefPubMed Lee SM, Kim SH, Ahn SJ, Kang HJ, Kang JH, Han JK. Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease. Eur Radiol. 2018;28(6):2525-34.CrossRefPubMed
28.
go back to reference Pan L, Jia X, Zhao X, Zhang B, Wang S, Fan T, et al. Study on the correlation between energy spectrum computed tomography imaging and the pathological characteristics and prognosis of cervical cancer. Transl Cancer Res. 2021;10(9):4096-105.CrossRefPubMedPubMedCentral Pan L, Jia X, Zhao X, Zhang B, Wang S, Fan T, et al. Study on the correlation between energy spectrum computed tomography imaging and the pathological characteristics and prognosis of cervical cancer. Transl Cancer Res. 2021;10(9):4096-105.CrossRefPubMedPubMedCentral
29.
go back to reference Nagayama Y, Iyama A, Oda S, Taguchi N, Nakaura T, Utsunomiya D, et al. Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: impact of closing k-edge on image quality and lesion detectability. Eur Radiol. 2019;29(6):2837-47.CrossRefPubMed Nagayama Y, Iyama A, Oda S, Taguchi N, Nakaura T, Utsunomiya D, et al. Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: impact of closing k-edge on image quality and lesion detectability. Eur Radiol. 2019;29(6):2837-47.CrossRefPubMed
30.
go back to reference Chinese Society of Gastroenterology Inflammatory bowel disease pathological group ZY, Shuyuan Xiao, Zengshan Li, Weixun Zhou, Xueying Shi, Fei Yuan, Du He, Kaichun Wu, Minhu Chen. Experts guideline on pathological assessment of inflammatory bowel disease in China. Chinese Journal of Inflammatory Bowel Diseases. 2021;05(01):5–20. Chinese Society of Gastroenterology Inflammatory bowel disease pathological group ZY, Shuyuan Xiao, Zengshan Li, Weixun Zhou, Xueying Shi, Fei Yuan, Du He, Kaichun Wu, Minhu Chen. Experts guideline on pathological assessment of inflammatory bowel disease in China. Chinese Journal of Inflammatory Bowel Diseases. 2021;05(01):5–20.
Metadata
Title
Improved Diagnostic Performance Using Dual-Energy CT-Derived Slope Parameter Images in Crohn’s Disease
Authors
Min Hong
Ziying Lin
Hua Zhong
Yan Zhang
Dan Yang
Sihui Zhong
Xiangrong Zhuang
Xin Yue
Publication date
13-11-2024
Publisher
Springer International Publishing
Keyword
Crohn's Disease
Published in
Journal of Imaging Informatics in Medicine
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-024-01330-4