Skip to main content
Top

Critical but commonly neglected factors that affect contrast medium administration in CT

Published in:

Abstract

Objective

Past decades of research into contrast media injections and optimization thereof in radiology clinics have focused on scan acquisition parameters, patient-related factors, and contrast injection protocol variables. In this review, evidence is provided that a fourth bucket of crucial variables has been missed which account for previously unexplained phenomena and higher-than-expected variability in data. We propose how these critical factors should be considered and implemented in the contrast-medium administration protocols to optimize contrast enhancement.

Methods

This article leverages a combination of methodologies for uncovering and quantifying confounding variables associated with or affecting the contrast-medium injection. Engineering benchtop equipment such as Coriolis flow meters, pressure transducers, and volumetric measurement devices are combined with small, targeted systematic evaluations querying operators, equipment, and the physics and fluid dynamics that make a seemingly simple task of injecting fluid into a patient a complex and non-linear endeavor.

Results

Evidence is presented around seven key factors affecting the contrast-medium injection including a new way of selecting optimal IV catheters, degraded performance from longer tubing sets, variability associated with the mechanical injection system technology, common operator errors, fluids exchanging places stealthily based on gravity and density, wasted contrast media and inefficient saline flushes, as well as variability in the injected flow rate vs. theoretical expectations.

Conclusion

There remain several critical, but not commonly known, sources of error associated with contrast-medium injections. Elimination of these hidden sources of error where possible can bring immediate benefits and help to drive standardized and optimized contrast-media injections.

Critical relevance statement

This review brings to light the commonly neglected/unknown factors negatively impacting contrast-medium injections and provides recommendations that can result in patient benefits, quality improvements, sustainability increases, and financial benefits by enabling otherwise unachievable optimization.

Key Points

  • How IV contrast media is administered is a rarely considered source of CT imaging variability.
  • IV catheter selection, tubing length, injection systems, and insufficient flushing can result in unintended variability.
  • These findings can be immediately addressed to improve standardization in contrast-enhanced CT imaging.

Graphical Abstract

Title
Critical but commonly neglected factors that affect contrast medium administration in CT
Authors
Michael C. McDermott
Joachim E. Wildberger
Kyongtae T. Bae
Publication date
01-12-2024
Publisher
Springer Vienna
Published in
Insights into Imaging / Issue 1/2024
Electronic ISSN: 1869-4101
DOI
https://doi.org/10.1186/s13244-024-01750-4
This content is only visible if you are logged in and have the appropriate permissions.

How can your team use biomarkers to improve management of AD? (Link opens in a new window)

0.5 AMA PRA Category 1 Credit(s)

Our experts explore using biomarker tests and interpreting results, establishing a shared decision-making approach with patients and caregivers, and applying biomarker testing to guide treatment strategies.

This content is intended for healthcare professionals outside of the UK.

Supported by:
  • Lilly
Developed by: Springer Health+ IME
Learn more

How can you integrate PET into your practice? (Link opens in a new window)

1.5 AMA PRA Category 1 Credit(s)™

PET imaging is playing an increasingly critical role in managing AD. Our expert-led program will empower you with practical strategies and real-world case studies to effectively integrate it into clinical practice.

This content is intended for healthcare professionals outside of the UK.

Supported by:
  • Lilly
Developed by: Springer Health+ IME
Learn more
Image Credits
Alzheimer’s disease in the biomarker era: preparing the multidisciplinary care team/© Springer Healthcare IME, Navigating neuroimaging in Alzheimer’s care: Practical applications and strategies for integration/© Springer Healthcare IME