Skip to main content
Top

Open Access 09-07-2024 | Review

2D vs. 3D Evaluation of Osteocyte Lacunae - Methodological Approaches, Recommended Parameters, and Challenges: A Narrative Review by the European Calcified Tissue Society (ECTS)

Authors: Annika vom Scheidt, Johannes Krug, Patricia Goggin, Astrid Diana Bakker, Björn Busse

Published in: Current Osteoporosis Reports

Login to get access

Abstract

Purpose of Review

Quantification of the morphology of osteocyte lacunae has become a powerful tool to investigate bone metabolism, pathologies and aging. This review will provide a brief overview of 2D and 3D imaging methods for the determination of lacunar shape, orientation, density, and volume. Deviations between 2D-based and 3D-based lacunar volume estimations are often not sufficiently addressed and may give rise to contradictory findings. Thus, the systematic error arising from 2D-based estimations of lacunar volume will be discussed, and an alternative calculation proposed. Further, standardized morphological parameters and best practices for sampling and segmentation are suggested.

Recent Findings

We quantified the errors in reported estimation methods of lacunar volume based on 2D cross-sections, which increase with variations in lacunar orientation and histological cutting plane. The estimations of lacunar volume based on common practice in 2D imaging methods resulted in an underestimation of lacunar volume of up to 85% compared to actual lacunar volume in an artificial dataset. For a representative estimation of lacunar size and morphology based on 2D images, at least 400 lacunae should be assessed per sample.
Appendix
Available only for authorised users
Literature
4.
go back to reference Goggin PM, Zygalakis KC, Oreffo RO, Schneider P. High-resolution 3D imaging of osteocytes and computational modelling in mechanobiology: insights on bone development, ageing, health and disease. Eur Cell Mater. 2016;31:264–95. https://doi.org/10.22203/ecm.v031a18. Goggin PM, Zygalakis KC, Oreffo RO, Schneider P. High-resolution 3D imaging of osteocytes and computational modelling in mechanobiology: insights on bone development, ageing, health and disease. Eur Cell Mater. 2016;31:264–95. https://​doi.​org/​10.​22203/​ecm.​v031a18.
5.
go back to reference Heveran CM, Rauff A, King KB, Carpenter RD, Ferguson VL. A new open-source tool for measuring 3D osteocyte lacunar geometries from confocal laser scanning microscopy reveals age-related changes to lacunar size and shape in cortical mouse bone. Bone. 2018;110:115–127. https://doi.org/10.1016/j.bone.2018.01.018. Heveran CM, Rauff A, King KB, Carpenter RD, Ferguson VL. A new open-source tool for measuring 3D osteocyte lacunar geometries from confocal laser scanning microscopy reveals age-related changes to lacunar size and shape in cortical mouse bone. Bone. 2018;110:115–127. https://​doi.​org/​10.​1016/​j.​bone.​2018.​01.​018.
12.
go back to reference Williams KA, Gostling NJ, Steer JW, Oreffo ROC, Schneider P. Quantifying intracortical bone microstructure: a critical appraisal of 2D and 3D approaches for assessing vascular canals and osteocyte lacunae. J Anat. 2020;238(3):653–68. https://doi.org/10.1111/joa.13325. Williams KA, Gostling NJ, Steer JW, Oreffo ROC, Schneider P. Quantifying intracortical bone microstructure: a critical appraisal of 2D and 3D approaches for assessing vascular canals and osteocyte lacunae. J Anat. 2020;238(3):653–68. https://​doi.​org/​10.​1111/​joa.​13325.
17.
go back to reference Wölfel EM, Lademann F, Hemmatian H, Blouin S, Messmer P, Hofbauer LC, et al. Reduced bone Mass and increased osteocyte tartrate-resistant acid phosphatase (TRAP) activity, but not low mineralized matrix around Osteocyte Lacunae, are restored after recovery from exogenous hyperthyroidism in male mice. J Bone Min Res. 2023;38:131–43. https://doi.org/10.1002/jbmr.4736. Wölfel EM, Lademann F, Hemmatian H, Blouin S, Messmer P, Hofbauer LC, et al. Reduced bone Mass and increased osteocyte tartrate-resistant acid phosphatase (TRAP) activity, but not low mineralized matrix around Osteocyte Lacunae, are restored after recovery from exogenous hyperthyroidism in male mice. J Bone Min Res. 2023;38:131–43. https://​doi.​org/​10.​1002/​jbmr.​4736.
18.
19.
24.
go back to reference Egerton RF. The transmission Electron microscope In: Physical Principles of Electron Microscopy. Boston, MA: Springer; 2005.CrossRef Egerton RF. The transmission Electron microscope In: Physical Principles of Electron Microscopy. Boston, MA: Springer; 2005.CrossRef
26.
27.
go back to reference Hongo H, Hasegawa T, Saito M, Tsuboi K, Yamamoto T, Sasaki M, et al. Osteocytic osteolysis in PTH-treated wild-type and rankl(-/-) mice examined by transmission electron microscopy, atomic force microscopy, and isotope microscopy. J Histochem Cytochem. 2020;68(10):651–68. https://doi.org/10.1369/0022155420961375. Hongo H, Hasegawa T, Saito M, Tsuboi K, Yamamoto T, Sasaki M, et al. Osteocytic osteolysis in PTH-treated wild-type and rankl(-/-) mice examined by transmission electron microscopy, atomic force microscopy, and isotope microscopy. J Histochem Cytochem. 2020;68(10):651–68. https://​doi.​org/​10.​1369/​0022155420961375​.
31.
go back to reference Milovanovic P, Rakocevic Z, Djonic D, Zivkovic V, Hahn M, Nikolic S, et al. Nano-structural, compositional and micro-architectural signs of cortical bone fragility at the superolateral femoral neck in elderly hip fracture patients vs. healthy aged controls. Exp Gerontol. 2014;55:19–28. https://doi.org/10.1016/j.exger.2014.03.001. Milovanovic P, Rakocevic Z, Djonic D, Zivkovic V, Hahn M, Nikolic S, et al. Nano-structural, compositional and micro-architectural signs of cortical bone fragility at the superolateral femoral neck in elderly hip fracture patients vs. healthy aged controls. Exp Gerontol. 2014;55:19–28. https://​doi.​org/​10.​1016/​j.​exger.​2014.​03.​001.
34.
36.
go back to reference Nguyen TD, Gu Y. Determination of strain-rate-dependent mechanical behavior of living and fixed osteocytes and chondrocytes using atomic force microscopy and inverse finite element analysis. J Biomech Eng. 2014;36(10):101004. https://doi.org/10.1115/1.4028098. Nguyen TD, Gu Y. Determination of strain-rate-dependent mechanical behavior of living and fixed osteocytes and chondrocytes using atomic force microscopy and inverse finite element analysis. J Biomech Eng. 2014;36(10):101004. https://​doi.​org/​10.​1115/​1.​4028098.
39.
go back to reference Xu J, Rho JY, Mishra SR, Fan Z. Atomic force microscopy and nanoindentation characterization of human lamellar bone prepared by microtome sectioning and mechanical polishing technique. J Biomed Mater Res A. 2003;67(3):719–26. https://doi.org/10.1002/jbm.a.10109. Xu J, Rho JY, Mishra SR, Fan Z. Atomic force microscopy and nanoindentation characterization of human lamellar bone prepared by microtome sectioning and mechanical polishing technique. J Biomed Mater Res A. 2003;67(3):719–26. https://​doi.​org/​10.​1002/​jbm.​a.​10109.
44.
go back to reference Canette A, Briandet R. Confocal laser scanning Microscopy In: Encyclopedia of Food Microbioligy (Second Edition). 2014. p. 676–83. Canette A, Briandet R. Confocal laser scanning Microscopy In: Encyclopedia of Food Microbioligy (Second Edition). 2014. p. 676–83.
53.
go back to reference Jemielita M, Taormina MJ, Delaurier A, Kimmel CB, Parthasarathy R. Comparing phototoxicity during the development of a zebrafish craniofacial bone using confocal and light sheet fluorescence microscopy techniques. J Biophotonics. 2013;6:11–2. https://doi.org/10.1002/jbio.201200144. Jemielita M, Taormina MJ, Delaurier A, Kimmel CB, Parthasarathy R. Comparing phototoxicity during the development of a zebrafish craniofacial bone using confocal and light sheet fluorescence microscopy techniques. J Biophotonics. 2013;6:11–2. https://​doi.​org/​10.​1002/​jbio.​201200144.
54.
go back to reference Moatti A, Cai Y, Li C, Sattler T, Edwards L, Piedrahita J, et al. Three-dimensional imaging of intact porcine cochlea using tissue clearing and custom-built light-sheet microscopy. Biomed Opt Express. 2020;11:6181–96. https://doi.org/10.1364/BOE.402991. Moatti A, Cai Y, Li C, Sattler T, Edwards L, Piedrahita J, et al. Three-dimensional imaging of intact porcine cochlea using tissue clearing and custom-built light-sheet microscopy. Biomed Opt Express. 2020;11:6181–96. https://​doi.​org/​10.​1364/​BOE.​402991.
61.
go back to reference Shah FA, Johansson BR, Thomsen P, Palmquist A. Ultrastructural evaluation of shrinkage artefacts induced by fixatives and embedding resins on osteocyte processes and pericellular space dimensions. J Biomed Mater Res A. 2015;103(4):1565–76. https://doi.org/10.1002/jbm.a.35287. Shah FA, Johansson BR, Thomsen P, Palmquist A. Ultrastructural evaluation of shrinkage artefacts induced by fixatives and embedding resins on osteocyte processes and pericellular space dimensions. J Biomed Mater Res A. 2015;103(4):1565–76. https://​doi.​org/​10.​1002/​jbm.​a.​35287.
64.
go back to reference Hasegawa T, Endo T, Tsuchiya E, Kudo Ai, Shen Z, Moritani Y, et al. Biological application of focus ion beam-scanning electron microscopy (FIB-SEM) to the imaging of cartilaginous fibrils and osteoblastic cytoplasmic processes, (in English). J Oral Biosci. 2017;59(1):55–62. https://doi.org/10.1016/j.job.2016.11.004. Hasegawa T, Endo T, Tsuchiya E, Kudo Ai, Shen Z, Moritani Y, et al. Biological application of focus ion beam-scanning electron microscopy (FIB-SEM) to the imaging of cartilaginous fibrils and osteoblastic cytoplasmic processes, (in English). J Oral Biosci. 2017;59(1):55–62. https://​doi.​org/​10.​1016/​j.​job.​2016.​11.​004.
67.
68.
73.
go back to reference Kamioka H, Murshid SA, Ishihara Y, Kajimura N, Hasegawa T, Ando R, et al. A method for observing silver-stained osteocytes in situ in 3-microm sections using ultra-high voltage electron microscopy tomography. Microsc Microanal. 2009;15(5):377–83. https://doi.org/10.1017/S1431927609990420. Kamioka H, Murshid SA, Ishihara Y, Kajimura N, Hasegawa T, Ando R, et al. A method for observing silver-stained osteocytes in situ in 3-microm sections using ultra-high voltage electron microscopy tomography. Microsc Microanal. 2009;15(5):377–83. https://​doi.​org/​10.​1017/​S143192760999042​0.
74.
76.
79.
go back to reference Palacio-Mancheno PE, Larriera AI, Doty SB, Cardoso L, Fritton SP. 3D assessment of cortical bone porosity and tissue mineral density using high-resolution microCT: effects of resolution and threshold method. J Bone Min Res. 2014;29(1):142–50. https://doi.org/10.1002/jbmr.2012. Palacio-Mancheno PE, Larriera AI, Doty SB, Cardoso L, Fritton SP. 3D assessment of cortical bone porosity and tissue mineral density using high-resolution microCT: effects of resolution and threshold method. J Bone Min Res. 2014;29(1):142–50. https://​doi.​org/​10.​1002/​jbmr.​2012.
83.
go back to reference Kormilina T, Englisch S, Kochetkova T, Drobek D, Wirth J, Zubiri BA, et al. Multi-modal characterization of collagen fibril orientation in human cortical bone by a combination of quantitative polarized Raman spectroscopy, nanoscale X-ray computed tomography and 360° electron tomography. Microsc Microanal. 2021;27(1):96–101. https://doi.org/10.1017/S1431927621000970. Kormilina T, Englisch S, Kochetkova T, Drobek D, Wirth J, Zubiri BA, et al. Multi-modal characterization of collagen fibril orientation in human cortical bone by a combination of quantitative polarized Raman spectroscopy, nanoscale X-ray computed tomography and 360° electron tomography. Microsc Microanal. 2021;27(1):96–101. https://​doi.​org/​10.​1017/​S143192762100097​0.
87.
100.
go back to reference Blouin S, Fratzl-Zelman?N, Glorieux?FH, Roschger?P,?Klaushofer?K,?Marini JC, et al. Hypermineralization and high osteocyte lacunar density in osteogenesis imperfecta type V bone indicate exuberant primary bone formation. J Bone Min Res. 1996;18(2):109–13. https://doi.org/10.1002/jbmr.3180. Blouin S, Fratzl-Zelman?N, Glorieux?FH, Roschger?P,?Klaushofer?K,?Marini JC, et al. Hypermineralization and high osteocyte lacunar density in osteogenesis imperfecta type V bone indicate exuberant primary bone formation. J Bone Min Res. 1996;18(2):109–13. https://​doi.​org/​10.​1002/​jbmr.​3180.
103.
go back to reference Schemenz V, Gjardy A, Chamasemani FF, Roschger A, Roschger P, Zaslansky P, et al. Heterogeneity of the osteocyte lacuno-canalicular network architecture and material characteristics across different tissue types in healing bone. J Struct Biol. 2020;212(2):107616. https://doi.org/10.1016/j.jsb.2020.107616. Schemenz V, Gjardy A, Chamasemani FF, Roschger A, Roschger P, Zaslansky P, et al. Heterogeneity of the osteocyte lacuno-canalicular network architecture and material characteristics across different tissue types in healing bone. J Struct Biol. 2020;212(2):107616. https://​doi.​org/​10.​1016/​j.​jsb.​2020.​107616.
105.
go back to reference Mähr M, Blouin S, Behanova M, Misof BM, Glorieux FH, Zwerina J, et al. Increased osteocyte Lacunae Density in the hypermineralized bone matrix of children with Osteogenesis Imperfecta Type I. Int J Mol Sci. 2021;22(9). https://doi.org/10.3390/ijms22094508. Mähr M, Blouin S, Behanova M, Misof BM, Glorieux FH, Zwerina J, et al. Increased osteocyte Lacunae Density in the hypermineralized bone matrix of children with Osteogenesis Imperfecta Type I. Int J Mol Sci. 2021;22(9). https://​doi.​org/​10.​3390/​ijms22094508.
Metadata
Title
2D vs. 3D Evaluation of Osteocyte Lacunae - Methodological Approaches, Recommended Parameters, and Challenges: A Narrative Review by the European Calcified Tissue Society (ECTS)
Authors
Annika vom Scheidt
Johannes Krug
Patricia Goggin
Astrid Diana Bakker
Björn Busse
Publication date
09-07-2024
Publisher
Springer US
Published in
Current Osteoporosis Reports
Print ISSN: 1544-1873
Electronic ISSN: 1544-2241
DOI